Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Methods Inf Med ; 53(2): 121-36, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24573195

RESUMO

BACKGROUND: Heart failure (HF) is affecting millions of people every year and it is characterized by impaired ventricular performance, exercise intolerance and shortened life expectancy. Despite significant advancements in drug therapy, mortality of the disease remains excessively high, as heart transplant remains the gold standard treatment for end-stage HF when no contraindications subsist. Traditionally, implanted Ventricular Assist Devices (VADs) have been employed in order to provide circulatory support to patients who cannot survive the waiting time to transplantation, reducing the workload imposed on the heart. In many cases that process could recover its contractility performance. OBJECTIVES: The SensorART platform focuses on the management and remote treatment of patients suffering from HF. It provides an interoperable, extendable and VAD-independent solution, which incorporates various hardware and software components in a holistic approach, in order to improve the quality of the patients' treatment and the workflow of the specialists. This paper focuses on the description and analysis of Specialist's Decision Support System (SDSS), an innovative component of the SensorART platform. METHODS: The SDSS is a Web-based tool that assists specialists on designing the therapy plan for their patients before and after VAD implantation, analyzing patients' data, extracting new knowledge, and making informative decisions. RESULTS: SDSS offers support to medical and VAD experts through the different phases of VAD therapy, incorporating several tools covering all related fields; Statistics, Association Rules, Monitoring, Treatment, Weaning, Speed and Suction Detection. CONCLUSIONS: SDSS and its modules have been tested in a number of patients and the results are encouraging.


Assuntos
Técnicas de Apoio para a Decisão , Insuficiência Cardíaca/terapia , Coração Auxiliar , Monitorização Fisiológica , Cuidados Pós-Operatórios , Consulta Remota , Software , Terapia Assistida por Computador , Sistemas Inteligentes , Humanos , Internet , Planejamento de Assistência ao Paciente , Melhoria de Qualidade , Fluxo de Trabalho
2.
Pharmacol Ther ; 134(2): 189-99, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22281238

RESUMO

Heart failure (HF) is a global epidemic that continues to cause significant morbidity and mortality despite advances in medical therapy. Ventricular assist device technology has emerged as a therapeutic option to bridge patients with end-stage HF to heart transplantation or as an alternative to transplantation in selected patients. In some patients, mechanical unloading induced by ventricular assist devices leads to improvement of myocardial function and a possibility of device removal. The implementation of this advanced technology requires multiple pharmacological interventions, both in the perioperative and long-term periods, in order to minimize potential complications and improve patient outcomes. We herein review the latest available evidence supporting the use of specific pharmacological interventions and current practices in the care of these patients: anticoagulation, bleeding management, pump thrombosis, infections, arrhythmias, right ventricular failure, hypertension, desensitization protocols, among others. Areas of uncertainty and ground for future research are also highlighted.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Animais , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Próteses e Implantes
3.
Int J Artif Organs ; 25(12): 1160-5, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12518960

RESUMO

UNLABELLED: Heart rate (HR) has been characterized as an important cardiovascular parameter that affects acute hemodynamic performance of intra-aortic balloon counterpulsation (IABC). However, the effect of HR on hemodynamics during mechanical assistance by the IABC has neither been clarified nor quantified. We sought to evaluate the relationship between IABC and HR and also to examine whether there is a range of HR with optimum hemodynamic response to IABC. METHODS: 20 patients (14 males--6 females, mean age 64.4 +/- 11.4 years) with post-infarction cardiogenic shock undergoing IABC treatment were evaluated. Hemodynamics were recorded for each patient once per day during the assistance period; 131 measurements were taken and thus a wide range of heart rates was obtained (64-141 bpm). The following changes in aortic pressures were used to evaluate acute IABC performance on: a) the maximal increase of diastolic aortic pressure induced by IABC and b) the reduction in systolic and end-diastolic aortic pressure. RESULTS: Non-linear regression analysis and analysis of variance revealed that a significant correlation exists between IABC performance indices and heart rate. At HR<80 bpm, IABC performance tended to be reduced, whereas the increase in HR above 110 bpm resulted in a significant reduction of all IABC performance indices. In contrast, IABC operating at 80-110 bpm resulted in optimum hemodynamic performance. In conclusion, the effect of heart rate on IABC performance is non-linear indicating that IABC may be more effective when operating within 80-110 bpm.


Assuntos
Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Balão Intra-Aórtico , Infarto do Miocárdio/fisiopatologia , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Análise de Regressão , Choque Cardiogênico/etiologia , Resultado do Tratamento
4.
Int J Artif Organs ; 24(7): 478-83, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11510920

RESUMO

Data concerning the effect of arterial compliance (AC) on hemodynamics during intraaortic balloon counterpulsation (IABC) are lacking. This study examines the effect of AC on acute hemodynamics induced by IABC in 15 patients with post-infarction cardiogenic shock. AC was estimated by aortic pulse wave analysis using the reflection time index (RTI). Measurements were obtained once per day during IABC. The % reduction in systolic aortic pressure (ASAP), end-diastolic aortic pressure (AEDAP) and the peak aortic diastolic augmentation (PADA) were used as performance indices of IABC; 107 sets of measurements were obtained. Multivariate analysis indicated an independent association of each IABC performance index with AC (p<0.05). A high AC group (RTI< or =20.6%, n=40) and a low AC group (RTI>20.6%, n=67) were obtained. DeltaSAP deltaEDAP and PADA were significantly higher in the low AC group by almost 75%, 54.6% and 11.3% (p<0.03), while arterial blood pressure did not significantly differ. Arterial compliance is an independent factor affecting hemodynamics during IABC. RTI values higher than 20.6% may predict a better acute hemodynamic response to IABC.


Assuntos
Aorta/fisiologia , Complacência (Medida de Distensibilidade) , Hemodinâmica , Idoso , Aorta Torácica/fisiologia , Feminino , Artéria Femoral/fisiologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes
5.
J Cardiovasc Surg (Torino) ; 42(1): 27-35, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11292902

RESUMO

BACKGROUND: The effect on infarct size of a pre-infarction high-grade, fixed coronary arterial stenosis maintained during reperfusion, was evaluated. METHODS: This experimental study was carried out in the research laboratory of a University Hospital. A canine occlusion-reperfusion model was used. Twenty-eight dogs underwent proximal left anterior descending (LAD) coronary artery occlusion (O). In Group 1 (n=6) the O lasted for 6 hours. In Group 2 (n=6) the O lasted for 2 hours followed by 4 hours of reperfusion (R). In Group 3 (n=3), LAD was stenosed for 30 minutes followed by O for 6 hours. In Group 4 (n=7) LAD was stenosed for 30 minutes followed by O for 2 hours and then 4 hours of R during which the artery was kept stenosed at the same degree (fixed) as the initial one. In Group 5 (n=6) the protocol was identical to Group 4 with the additional use of the intra-aortic balloon pump during R. RESULTS: The infarcted myocardium was almost the same in Groups 1 and 3 (80.0+/-10.6% vs 77.3+/-3.8%, respectively, p=NS), but less in Group 2 (59.0+/-19.9%, p=0.046 vs Group 1). There were no hemodynamic differences between Groups 4 and 5 and the infarcted myocardium was almost identical in both groups (37.7+/-18.8% and 38.7+/-19.1%, respectively, p=NS). The combined results of Groups 4 and 5, regarding the infarcted myocardium, was 38.1+/-18% (p=0.037 vs Group 2). CONCLUSIONS: In this acute coronary occlusion model, a pre-existing high-grade stenosis that maintained during reperfusion increased the amount of salvaged ischemic myocardium.


Assuntos
Circulação Coronária , Vasos Coronários/patologia , Precondicionamento Isquêmico Miocárdico , Infarto do Miocárdio/patologia , Miocárdio/patologia , Animais , Artérias/patologia , Constrição , Cães , Hemodinâmica , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Reperfusão Miocárdica , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA