Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Surg Case Rep ; 119: 109746, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38728968

RESUMO

INTRODUCTION: Compartment syndrome is an emergency which requires prompt intervention. While main challenge typically revolves around determining necessity for fasciotomy in suspected cases, etiology is often pronounced, leaving little room for differential diagnosis. CASE REPORT: We report a case with unconventional presentation and clinical course, ultimately diagnosed as Munchausen Syndrome. DISCUSSION: It has been reported that individuals with Munchausen syndrome are successful at manipulating healthcare professionals. They often study the symptoms of their sickness, examination findings, and findings that may alert doctors, mastering their techniques over time. CONCLUSION: It is of importance to consider Munchausen Syndrome as a potential cause, particularly in cases where clinical history and course of symptoms do not align with our experiences and cannot be reconciled with other possible diagnostic patterns.

2.
Arthroscopy ; 40(3): 683-691, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37394152

RESUMO

PURPOSE: To investigate the histological and biomechanical effects of a fibroblast growth factor (FGF-2)-soaked collagen membrane used to treat a full-thickness chronic rotator cuff (RC) rupture in a rabbit model. METHODS: Forty-eight shoulders from 24 rabbits were used. At the beginning of the procedure, 8 rabbits were killed to assess the control group (Group IT) with intact tendons. To establish a chronic RC tear model, a full-thickness subscapularis tear was created on both shoulders of the remaining 16 rabbits and left for 3 months. The transosseous mattress suture technique was used to repair tears in the left shoulder (Group R). The tears in the right shoulder (Group CM) were treated using the same approach, with an FGF-soaked collagen membrane inserted and sutured over the repair site. Three months after the procedure, all rabbits were killed. Biomechanical testing was performed on the tendons to determine failure load, linear stiffness, elongation intervals, and displacement. Histologically, the modified Watkins score was used to evaluate tendon-bone healing. RESULTS: There was no significant difference among the three groups in terms of failure load, displacement, linear stiffness, and elongation (P > .05). The total modified Watkins score was not affected by applying the FGF-soaked collagen membrane to the repair site (P > .05). Fibrocytes, parallel cells, large-diameter fibers, and the total modified Watkins score were significantly lower in both repair groups when compared to the intact tendon group (P < .05). CONCLUSIONS: In addition to tendon repair, FGF-2 soaked collagen membrane -application at the repair site provides neither biomechanical nor histological advantages in the treatment of chronic RC tears. CLINICAL RELEVANCE: FGF-soaked collagen membrane augmentation provides no impact on the chronic RC tear healing tissue. The need to investigate alternative methods that may have a positive effect on healing in chronic RC repairs continues.


Assuntos
Lesões do Manguito Rotador , Animais , Coelhos , Lesões do Manguito Rotador/tratamento farmacológico , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Fatores de Crescimento de Fibroblastos , Fator 2 de Crescimento de Fibroblastos/farmacologia , Fator 2 de Crescimento de Fibroblastos/uso terapêutico , Manguito Rotador/cirurgia , Manguito Rotador/patologia , Colágeno/farmacologia , Colágeno/uso terapêutico
3.
Clin Orthop Surg ; 15(2): 272-280, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37008966

RESUMO

Background: Septic arthritis of the shoulder is a rare but devastating condition that may lead to joint destruction. There are few studies and limited outcome data on shoulder arthroplasty for infected native shoulders with end-stage glenohumeral arthritis (GHA). Hence, this study aimed to demonstrate the clinical outcomes of two-stage implantation in reverse shoulder arthroplasty (RSA) using an antibiotic spacer in the first stage for this challenging condition. Methods: We conducted a retrospective study on two-stage implantation in RSA in infected shoulders. Patients were diagnosed with end-stage GHA due to primary shoulder sepsis or infection following non-arthroplasty shoulder surgery. Laboratory data, range of motion (ROM), and functional scores including American Shoulder and Elbow Surgeons score, Constant score, and Disabilities of the Arm, Shoulder and Hand score were assessed prior to spacer placement and at the latest follow-up. Furthermore, intraoperative and postoperative complications were recorded. Results: In this study, 10 patients with a mean age of 54.8 ± 15.8 years (range, 30-77 years) were included. The mean follow-up period was 37.3 ± 9.1 months (range, 25-56 months). All postoperative ROM measurements and functional scores were improved significantly. Although no reinfection was observed, a total of 5 complications including 2 hematomas, 1 intraoperative humeral fracture, 1 humeral stem loosening, and 1 anterior deltoid dysfunction were observed in 4 patients after a follow-up period of at least 2 years after RSA. Conclusions: Two-stage implantation in RSA is an effective method for improving the function and controlling the infection in postinfectious end-stage GHA in native shoulders.


Assuntos
Artrite Infecciosa , Artroplastia do Ombro , Articulação do Ombro , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Ombro/cirurgia , Articulação do Ombro/cirurgia , Estudos de Coortes , Seguimentos , Estudos Retrospectivos , Resultado do Tratamento , Artrite Infecciosa/cirurgia , Amplitude de Movimento Articular
4.
J Orthop Surg (Hong Kong) ; 30(1): 10225536221079432, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35220811

RESUMO

INTRODUCTION: Incorrect positioning is one of the main factors for glenoid component loosening in reverse shoulder arthroplasty and component placement can be challenging. This study aimed to assess whether Patient-Specific Instrumentation (PSI) provides better guide pin positioning accuracy and is superior to standard guided and freehand instrumentation methods in cases of glenoid bone deformity. MATERIALS AND METHODS: Based on the Walch classification, five different scapula types were acquired by computed tomography (CT). For each type, two different surgeons placed a guide pin into the scapula using three different methods: freehand method, conventional non-patient-specific guide, and PSI guide. Each method was repeated five times by both surgeons. In these experiments, a total of 150 samples of scapula models were used (5 × 2 × 3 × 5 = 150). Post-operative CT scans of the samples with the guide pin were digitally assessed and the accuracy of the pin placement was determined by comparison to the preoperative planning on a three-dimensional (3D) model. RESULTS: The PSI method showed accuracies to the preoperative plan of 2.68 (SD 2.10) degrees for version angle (p < .05), 2.59 (SD 2.68) degrees for inclination angle (p < .05), and 1.55 (SD 1.26) mm for entry point offset (p < .05). The mean and standard deviation errors compared to planned values of version angle, inclination angle, and entry point offset were statistically significant for the PSI method for the type C defected glenoid and non-arthritic glenoid. CONCLUSION: Using the PSI guide created by an image processing software tool for guide pin positioning showed advantages in glenoid component positioning over other methods, for defected and intact glenoid types, but correlation with clinical outcomes should be examined.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Artroplastia do Ombro/métodos , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Humanos , Imageamento Tridimensional/métodos , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA