Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 9(2): e86890, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24586256

RESUMO

BACKGROUND AND AIMS: Obesity and its associated cardiometabolic co-morbidities are increasing worldwide. Since thyroid hormone mimetics are capable of uncoupling the beneficial metabolic effects of thyroid hormones from their deleterious effects on heart, bone and muscle, this class of drug is considered as adjacent therapeutics to weight-lowering strategies. This study investigated the safety and efficacy of TRC150094, a thyroid hormone mimetic. MATERIALS AND METHODS: This 4-week, randomized, placebo-controlled, double-blind trial was conducted in India and The Netherlands. Forty subjects were randomized at a 1:1 ratio to receive either TRC150094 dosed at 50 mg or placebo once daily for 4 weeks. Hyperinsulinemic euglycemic clamp and (1)H-Magnetic Resonance Spectroscopy (MRS) were performed before and after treatment. RESULTS: At baseline, subjects were characterized by markedly impaired hepatic and peripheral insulin sensitivity. TRC150094 dosed 50 mg once daily was safe and well tolerated. Hepatic nor peripheral insulin sensitivity improved after TRC150094 treatment, expressed as the suppression of Endogenous Glucose Production from 59.5 to 62.1%; p = 0.477, and the rate of glucose disappearance from 28.8 to 26.4 µmol kg(-1)min(-1), p = 0.185. TRC150094 administration did not result in differences in fasting plasma free fatty acids from 0.51 to 0.51 mmol/L, p = 0.887 or in insulin-mediated suppression of lipolysis from 57 to 54%, p = 0.102. Also, intrahepatic triglyceride content was unaltered. CONCLUSION: Collectively, these data show that, in contrast to the potent metabolic effects in experimental models, TRC150094 at a dose of 50 mg daily does not improve the metabolic homeostasis in subjects at an increased cardiometabolic risk. Further studies are needed to evaluate whether TRC150094 has beneficial effects in patients with more severe metabolic derangement, such as overt diabetes mellitus and hypertriglyceridemia. TRIAL REGISTRATION: clinicaltrials.gov NCT01408667.


Assuntos
Di-Iodotironinas/farmacologia , Resistência à Insulina/fisiologia , Síndrome Metabólica/metabolismo , Tironinas/farmacologia , Adulto , Técnica Clamp de Glucose , Humanos , Índia , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Países Baixos , Estatísticas não Paramétricas
2.
Clin Drug Investig ; 29(9): 559-75, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19663519

RESUMO

BACKGROUND AND OBJECTIVE: Advanced glycation end-products (AGEs) have been implicated in the pathogenesis of diabetic complications through a variety of mechanisms including endothelial dysfunction and structural abnormalities in the vasculature and myocardium. Reducing the AGEs burden and their ensuing pro-inflammatory, pro-oxidative and pro-coagulant effect with associated dysfunctional proteins in various target tissues may retard the progression of and even reverse diabetic macro- and microvascular complications. Pyridinium, 3-[[2-(methylsulfonyl) hydrazino] carbonyl]-1-[2-oxo-2-2-thienyl) ethyl]-chloride (TRC4186) has demonstrated AGE-breaking activities in in vitro experiments and improvement in the endothelial and myocardial function in animal models of diabetes mellitus with reduction of AGEs accumulation in tissues over time. The safety of TRC4186 has been established in in vitro and in vivo preclinical studies. Thus, this drug is being developed for the treatment of complications associated with diabetes. This investigation set out to evaluate the safety, tolerability and pharmacokinetics of TRC4186 in healthy human subjects after single and multiple ascending doses, fixed doses in elderly male and female subjects, and with food and different formulations of the compound. METHODS: Four studies were conducted during phase I clinical development of TRC4186. These were: (i) a randomized, double-blind, placebo-controlled, single-dose, dose-ascending study in healthy male subjects with doses of TRC4186 ranging from 250 to 2500 mg administered as an oral solution (total six doses); (ii) a randomized, double-blind, placebo-controlled, multiple-dose, dose-ascending study in healthy male subjects with three doses of TRC4186 ranging from 500 to 2000 mg twice daily for 6 days with a final single dose on day 7; (iii) a randomized, open-label, three-way crossover study to assess the effect of food (fasted vs fed) and formulation (solution vs tablet) with TRC4186 500 mg; (iv) a randomized, double-blind, placebo-controlled, single-dose, dose-ascending study in elderly male and female subjects at a dose of TRC4186 500 mg followed by TRC4186 1000 mg after a 7-day washout period. The safety and tolerability of TRC4186 were assessed by considering adverse events (AEs), ECG findings, vital signs and laboratory investigation results. RESULTS: TRC4186 was rapidly absorbed, with maximum plasma concentrations (C(max)) attained within 1-4 hours. C(max) and area under the plasma concentration-time curve (AUC) were dose proportional over the range 250-2500 mg for a single dose and 500-2000 mg for multiple doses with twice-daily administration. Steady-state conditions were attained within 6 days at different dose levels. C(max) and AUC were not affected by age, sex, race or type of formulation. The tablet formulation of TRC4186 was bioequivalent with the solution form of the drug under fasting conditions and systemic availability of the tablet formulation was reduced by 40% when administered under fed conditions. Terminal elimination and renal clearance in the elderly male (age 69.1 +/- 6.0 years) were not significantly different compared with younger subjects (age 31 +/- 8.6 years). CONCLUSION: TRC4186 was safe and well tolerated when administered orally with either a single or multiple doses across the different ages, sexes, races and formulations studied. A dose-proportional increase in plasma TRC4186 concentration was seen, with steady state being achieved within 6 days.


Assuntos
Produtos Finais de Glicação Avançada/antagonistas & inibidores , Compostos de Piridínio/administração & dosagem , Sulfonamidas/administração & dosagem , Adolescente , Adulto , Fatores Etários , Idoso , Formas de Dosagem , Relação Dose-Resposta a Droga , Esquema de Medicação , Avaliação de Medicamentos , Eletrocardiografia/efeitos dos fármacos , Feminino , Interações Alimento-Droga , Humanos , Masculino , Pessoa de Meia-Idade , Compostos de Piridínio/efeitos adversos , Compostos de Piridínio/farmacocinética , Sulfonamidas/efeitos adversos , Sulfonamidas/farmacocinética , Equivalência Terapêutica
3.
Artigo em Inglês | MEDLINE | ID: mdl-15734161

RESUMO

A new method was developed for determination of itopride in human serum by reversed phase high-performance liquid chromatography (HPLC) with fluorescence detection (excitation at 291 nm and emission at 342 nm). The method employed one-step extraction of itopride from serum matrix with a mixture of tert-butyl methyl ether and dichloromethane (70:30, v/v) using etoricoxib as an internal standard. Chromatographic separation was obtained within 12.0 min using a reverse phase YMC-Pack AM ODS column (250 mm x 4.6 mm, 5 microm) and an isocratic mobile phase constituting of a mixture of 0.05% tri-fluoro acetic acid in water and acetonitrile (75:25, v/v) flowing at a flow rate of 1.0 ml/min. The method was linear in the range of 14.0 ng/ml to 1000.0 ng/ml. The lower limit of quantitation (LLOQ) was 14.0 ng/ml. Average recovery of itopride and the internal standard from the biological matrix was more than 66.04 and 64.57%, respectively. The inter-day accuracy of the drug containing serum samples was more than 97.81% with a precision of 2.31-3.68%. The intra-day accuracy was 96.91% or more with a precision of 5.17-9.50%. Serum samples containing itopride were stable for 180.0 days at -70+/-5 degrees C and for 24.0 h at ambient temperature (25+/-5 degrees C). The method was successfully applied to the bioequivalence study of itopride in healthy, male human subjects.


Assuntos
Benzamidas/sangue , Compostos de Benzil/sangue , Cromatografia Líquida de Alta Pressão/métodos , Absorção , Adulto , Benzamidas/isolamento & purificação , Benzamidas/farmacocinética , Compostos de Benzil/isolamento & purificação , Compostos de Benzil/farmacocinética , Estabilidade de Medicamentos , Congelamento , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Fluorescência , Equivalência Terapêutica
4.
Artigo em Inglês | MEDLINE | ID: mdl-15522722

RESUMO

A novel liquid chromatographic--electrospray ionisation mass spectrometric (LC--ESI-MS) method has been developed for the determination of escitalopram, an antidepressant in human plasma using paroxetine as internal standard. The method involved liquid--liquid extraction of the analyte from human plasma with a mixture of diethyl ether and dichloromethane (70:30, v/v). The chromatographic separation was achieved within 7.0 min by using 2.0 mM ammonium acetate (pH 5.0)--acetonitrile (54:46, v/v) as mobile phase and a ODS YMCAQ 150 mm x 4.6 mm analytical column; the flow-rate was 1.0 ml/min. Ion signals m/z 325.0 and 330.0 for escitalopram and internal standard, were measured in the positive mode. A detailed validation of the method was performed as per USFDA guidelines and the standard curves were found to be linear in the range of 1.0-200 ng/ml with a mean correlation coefficient more than 0.99. The absolute recovery was more than 75% for both escitalopram and internal standard. The method was simple, sensitive, precise, accurate and was successfully applied to the bioequivalence study of escitalopram in healthy, male, human subjects.


Assuntos
Cromatografia Líquida/métodos , Citalopram/sangue , Inibidores Seletivos de Recaptação de Serotonina/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Citalopram/farmacocinética , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Inibidores Seletivos de Recaptação de Serotonina/farmacocinética , Equivalência Terapêutica
5.
Ann Chim ; 94(12): 951-9, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15689031

RESUMO

A novel High Performance Liquid Chromatography-electrospray mass spectrometric method has been developed for the estimation of Ursodiol (Ursodeoxycholic acid)--a bile acid, in human plasma using Ornidazole as internal standard. The methodology involved solid phase extraction of the analyte from human plasma matrix. The chromatographic separation was achieved within seven minutes by an isocratic mobile phase containing 1.0 mM ammonium acetate and Acetonitrile (65:35, v/v), flowing through XTerra MS C18, 100 x 2.1, 3.5 microm analytical column, at a flow rate of 0.2 ml/min. Ion signals were measured in negative mode for Ursodiol and internal standard at m/z 391.3 and 278.1, respectively. A detailed validation of the method was performed as per USFDA guidelines and the standard curves were found to be linear in the range 50.0 ng/ml to 3000.0 ng/ml with the mean correlation coefficient more than 0.99. The absolute recovery was more than 54.90% for Ursodiol and 76.51% for internal standard. Ursodiol was stable for sixty-nine days at -70 degrees C and for eight hours at ambient temperature. After extraction from plasma, the reconstituted samples of Ursodiol were stable in autosampler at 10 degrees C for forty-eight hours. Upon subjecting to three freeze thaw cycles, there was no change in the recovery of the analyte. The integrity of the plasma samples remained unaffected even upon four-fold dilution with drug free human plasma. The method was simple, specific, sensitive, precise, accurate and suitable for bioequivalence and pharmacokinetic studies. It was successfully applied to the pilot bioequivalence study of Ursodiol in male human subjects.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Ácido Ursodesoxicólico/sangue , Colagogos e Coleréticos/química , Cromatografia Líquida de Alta Pressão/normas , Humanos , Masculino , Ornidazol/química , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA