Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Am Coll Cardiol ; 83(18): 1760-1772, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38588926

RESUMO

BACKGROUND: Hypertension guidelines recommend diagnosis and treatment of obstructive sleep apnea (OSA) in patients with hypertension. The mandibular advancement device (MAD) is an oral appliance therapy for patients who decline or cannot tolerate continuous positive airway pressure (CPAP). OBJECTIVES: We compared the relative effectiveness of MAD vs CPAP in reducing 24-hour ambulatory blood pressure (BP). METHODS: In an investigator-initiated, randomized, noninferiority trial (prespecified margin 1.5 mm Hg), 321 participants aged ≥40 years with hypertension and increased cardiovascular risk were recruited at 3 public hospitals for polysomnography. Of these, 220 participants with moderate-to-severe OSA (apnea-hypopnea index ≥15 events per hour) were randomized to either MAD or CPAP (1:1). The primary outcome was the difference between the 24-hour mean arterial BP at baseline and 6 months. RESULTS: Compared with baseline, the 24-hour mean arterial BP decreased by 2.5 mm Hg (P = 0.003) at 6 months in the MAD group, whereas no change was observed in the CPAP group (P = 0.374). The between-group difference was -1.6 mm Hg (95% CI: -3.51 to 0.24, noninferiority P < 0.001). The MAD group demonstrated a larger between-group reduction in all secondary ambulatory BP parameters compared with the CPAP group, with the most pronounced effects observed in the asleep BP parameters. Both the MAD and CPAP improved daytime sleepiness, with the between-group difference similar (P = 0.384). There were no between-group differences in cardiovascular biomarkers. CONCLUSIONS: MAD is noninferior to CPAP for reducing 24-hour mean arterial BP in participants with hypertension and increased cardiovascular risk. (Cardiosleep Research Program on Obstructive Sleep Apnea, Blood Pressure Control and Maladaptive Myocardial Remodeling-Non-inferiority Trial [CRESCENT]; NCT04119999).


Assuntos
Pressão Sanguínea , Pressão Positiva Contínua nas Vias Aéreas , Hipertensão , Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/fisiopatologia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Avanço Mandibular/instrumentação , Hipertensão/terapia , Hipertensão/fisiopatologia , Hipertensão/complicações , Pressão Sanguínea/fisiologia , Polissonografia , Idoso , Monitorização Ambulatorial da Pressão Arterial/métodos , Resultado do Tratamento
2.
J Hypertens ; 41(6): 1011-1017, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37071415

RESUMO

STUDY OBJECTIVE: Current hypertension guidelines recommend that at-risk individuals be screened for obstructive sleep apnea (OSA). The Belun Ring is a wearable OSA diagnostic device worn on the palmar side of the proximal phalanx of the index finger. METHODS: We recruited 129 participants (age: 60 ±â€Š8 years, male sex: 88%, BMI: 27 ±â€Š4 kg/m 2 ) with hypertension and high cardiovascular risk for a simultaneous polysomnography and Belun Ring monitoring for one night. Epworth Sleepiness Scale score more than 10 was detected in 27 (21.0%) participants. RESULTS: In the 127 participants who completed the study, the apnea-hypopnea index (AHI) derived from polysomnography was 18.1 (interquartile range: 33.0) events/h and that derived from the Belun Ring was 19.5 (interquartile range: 23.3) events/h [intraclass correlation coefficient: 0.882, 95% confidence interval (95% CI): 0.837-0.916]. A Bland-Altman plot showed the difference between the Belun Ring and polysomnography AHIs to be -1.3 ±â€Š10.4 events/h. Area under the receiver operating characteristic for the Belun Ring AHI was 0.961 (95% CI: 0.932-0.990, P  < 0.001). When the Belun Ring AHI of at least 15 events/h was used to diagnose OSA, the sensitivity, specificity, positive predictive value, and negative predictive value were 95.7, 77.6, 85.3, and 93.8%, respectively. The overall accuracy was 87.4%. The Cohen's kappa agreement was 0.74 ±â€Š0.09 ( P  < 0.001). Similar results were obtained when the oxygen desaturation index was used to diagnose OSA. CONCLUSION: A high prevalence of OSA was detected in patients with hypertension and high cardiovascular risk. The Belun Ring is a reliable device for OSA diagnosis similar to polysomnography.


Assuntos
Doenças Cardiovasculares , Hipertensão , Apneia Obstrutiva do Sono , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/etiologia , Fatores de Risco , Sono , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/diagnóstico , Hipertensão/complicações , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Fatores de Risco de Doenças Cardíacas
3.
Sleep ; 46(2)2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36130168

RESUMO

STUDY OBJECTIVES: Respiratory sleep indices are traditionally reported on the basis of the average total sleep time. The relationship between the hour-to-hour variability of these parameters and blood pressure (BP) has not been reported. METHODS: We evaluated the associations of the hour-to-hour variability of the apnea-hypopnea index (AHI), oxygen desaturation index (ODI), and lowest oxygen saturation with the 24-h ambulatory BP in patients with hypertension and newly diagnosed obstructive sleep apnea. A total of 147 patients underwent polysomnography, based on which obstructive sleep apnea was diagnosed in 106 patients; these patients underwent 24-h ambulatory BP monitoring within the next 30 days. Each polysomnogram was divided into hourly reports to calculate the variability of the respiratory sleep indices. Variability independent of the mean was considered the primary measure of variability. RESULTS: The median number of hourly polysomnogram reports was 7 (range, 4-8). The hour-to-hour variability of both AHI and ODI, but not of the lowest oxygen saturation, was correlated with the 24-h pulse pressure, 24-h systolic BP, and awake systolic BP (p < 0.05 for all). The fully adjusted linear regression analysis indicated that the hour-to-hour variability of AHI and ODI remained associated with the 24-h pulse pressure (AHI: ß coefficient, 0.264 [95% CI = 0.033-0.495], p = 0.026; ODI: ß coefficient, 0.450 [95% CI = 0.174-0.726], p = 0.002). CONCLUSIONS: The hour-to-hour variability of AHI and ODI is independently associated with the 24-h pulse pressure. Further investigations are warranted to evaluate the clinical relevance of this new-found association.


Assuntos
Hipertensão , Apneia Obstrutiva do Sono , Humanos , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial , Sono , Hipertensão/diagnóstico , Oxigênio
4.
J Clin Sleep Med ; 18(5): 1463-1465, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35022127

RESUMO

A patient with obstructive sleep apnea was admitted to the hospital with non-ST segment elevation myocardial infarction. An angiotensin-converting enzyme inhibitor was prescribed upon discharge. She later became intolerant to continuous positive airway pressure therapy, and her adherence to the related device decreased precipitously. The intolerance subsided gradually after a switch in medication to an angiotensin receptor blocker, and her adherence to continuous positive airway pressure device usage returned to baseline after 4 weeks. CITATION: Ou Y-H, Thant AT, Lee C-H. Sudden deterioration of CPAP adherence after myocardial infarction in a Chinese patient: potential effect of ACEI-induced airway hyperresponsiveness. J Clin Sleep Med. 2022;18(5):1463-1465.


Assuntos
Infarto do Miocárdio , Apneia Obstrutiva do Sono , China , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/tratamento farmacológico , Cooperação do Paciente , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia
5.
Sleep Breath ; 25(1): 125-133, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32270424

RESUMO

PURPOSE: Obstructive sleep apnea (OSA) during the rapid eye movement (REM) stage of the sleep cycle is associated with intense hypoxemia and cardiovascular instability. We characterized OSA during REM sleep in patients after percutaneous coronary intervention. METHODS: In this multicenter study, 204 patients who had undergone percutaneous coronary intervention in the prior 6 to 36 months were recruited for in-laboratory polysomnography. The primary measure was respiratory events during REM sleep. The patients were divided into 2 groups: (1) OSA during REM sleep (≥ 15 events/h) and (2) absence of OSA during REM sleep (< 15 events/h). RESULTS: Based on the overall apnea-hypopnea index ≥ 15, 148 patients (74.0%) had OSA. After excluding patients with failed polysomnography or REM sleep < 30 min, 163 patients formed the cohort for this analysis. OSA during REM sleep was diagnosed in 132 patients (81%). Compared with the patients without OSA during REM sleep, those with OSA during REM sleep had a higher body mass index (p = 0.003) and systolic blood pressure (p = 0.041), and a higher prevalence of diabetes mellitus (p = 0.029). Logistic regression analysis, including age, sex, diabetes mellitus, indication for percutaneous coronary intervention, and indication for multi-vessel percutaneous coronary intervention, showed that diabetes mellitus was the only independent predictor of OSA during REM sleep (odds ratio 2.83; 95% CI, 1.17 to 6.83; p = 0.021). CONCLUSION: In patients treated with percutaneous coronary intervention, there was a high prevalence of OSA during REM sleep. Diabetes mellitus was an independent predictor of OSA during REM sleep.


Assuntos
Diabetes Mellitus , Intervenção Coronária Percutânea , Apneia Obstrutiva do Sono/fisiopatologia , Sono REM/fisiologia , Síndrome Coronariana Aguda/terapia , Idoso , Angina Estável/terapia , Pressão Sanguínea/fisiologia , Índice de Massa Corporal , Comorbidade , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea/estatística & dados numéricos , Polissonografia , Apneia Obstrutiva do Sono/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA