Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Invest Surg ; 34(1): 30-38, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31179793

RESUMO

Aim of the Study: Mason type III radial head fractures are a source of concern due to the severe injury and poor recovery. At present, radial head resection, open reduction and internal fixation (ORIF), and prosthetic replacement are three common treatment methods for these fractures. The clinical efficacy and postoperative complications are controversial, which makes it difficult for physicians to determine the most appropriate regimen. Herein, this present prospective, non-randomized, parallel-controlled study was conducted to compare the therapeutic effects and identify the most effective treatment method for Mason type III radial head fracture. Materials and Methods: We assessed patients with Mason type III radial head fracture treated with resection, prosthetic replacement, and ORIF to compare preoperative and postoperative pain condition, elbow joint function, curative effect, and complication rate. A visual analog scale was used to score pain. The elbow joint function was observed using the Broberg-Morrey elbow joint score. Results: No significant differences were found in patient demographics among the resection, prosthetic replacement, and ORIF groups. The prosthetic replacement and ORIF procedures were more complex and had higher technical requirements. Prosthetic replacement and ORIF enabled higher elbow joint scores and lower pain scores than resection. Excellent and good ratings were highest and complication rates were lowest in the prosthetic replacement group, followed by the ORIF group. Conclusion: Our results showed that prosthetic replacement is more effective than ORIF and radial head resection in relieving pain, functional recovery and reducing complications in the treatment of Mason type III radial head fractures.


Assuntos
Articulação do Cotovelo , Fraturas Cominutivas , Fraturas do Rádio , Fixação Interna de Fraturas , Humanos , Estudos Prospectivos , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
2.
Int Orthop ; 43(10): 2303-2308, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30377699

RESUMO

PURPOSE: Knee arthroscopy, with its unique advantages, has become a routine surgery and is widely carried out around the world. Venous thromboembolism (VTE) after knee arthroscopy is a potentially serious complication. This article analyzes the effects of anticoagulant therapy after knee arthroscopy. METHODS: We used key words or entry terms without any limitations to search the PubMed, Embase, and Cochrane Library databases. Randomized controlled trials (RCTs) of drug prophylaxis for VTE after knee arthroscopy until November 2017 were included in our review. RESULTS: This systematic review identified nine RCTs, consisting of 4290 patients, investigating drug prophylaxis in knee arthroscopy. There are three main drugs for preventing thrombosis after arthroscopic knee surgery: low-molecular-weight heparin (LMWH), rivaroxaban, and aspirin. Our study concluded that there is no difference in symptomatic VTE (excluding symptomatic distal DVT) risk during anticoagulant prophylaxis (RR, 0.98; 95% CI, 0.44-2.19; I2 value = 0%; P = 0.97). Moreover, there was a lower incidence of symptomatic distal DVT (RR, 0.16; 95% CI, 0.06-0.45; I2 value = 0%; P = 0.0005) in the anticoagulant group than in the control group. CONCLUSIONS: In our study, anticoagulant therapy after knee arthroscopy was ineffective. We recommend that anticoagulants not be provided routinely after knee arthroscopy.


Assuntos
Anticoagulantes/uso terapêutico , Artroscopia/efeitos adversos , Heparina de Baixo Peso Molecular/uso terapêutico , Articulação do Joelho/cirurgia , Tromboembolia Venosa/prevenção & controle , Trombose Venosa/prevenção & controle , Humanos , Tromboembolia Venosa/etiologia , Trombose Venosa/etiologia
3.
PLoS One ; 13(6): e0197868, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29927930

RESUMO

BACKGROUND: Venous thromboembolism (VTE) is considered a potentially serious complication of knee arthroscopy and leads to conditions such as deep venous thrombosis (DVT) and pulmonary embolism (PE). Low-molecular-weight heparin (LMWH) is widely employed in knee arthroscopy to reduce perioperative thromboembolic complications. However, the efficacy and safety of LMWH in knee arthroscopy remains unclear. METHODS: Seven randomized controlled clinical trials on LMWH in knee arthroscopy were identified and included in this meta-analysis. The main outcomes of the effectiveness (prevention of DVT and PE) and complications (death, major bleeding, and minor bleeding) of LMWH in knee arthroscopic surgery were assessed using Review Manager 5.3 software. RESULTS: The meta-analysis indicated that LMWH prophylaxis comprised 79% of asymptomatic DVT. No association was found in symptomatic VTE (RR: 0.90; 95% confidence interval [CI]: 0.39-2.08; P = 0.80), symptomatic DVT (RR: 0.79; 95% CI: 0.28-2.23; P = 0.66), symptomatic PE (RR: 1.36; 95% CI: 0.37-4.97; P = 0.64) and major bleeding (RR: 0.70; 95% CI: 0.12-3.95; P = 0.68) risk during LMWH prophylaxis were identified. Death was not reported in these studies. Moreover, there was a lower incidence of minor bleeding (RR: 0.64; 95% CI: 0.49 to 0.83; P = 0.001) in the control group than in the LMWH group. CONCLUSION: Compared with the control group, the group treated with LMWH after knee arthroscopy was no association in reducing the symptomatic VTE rate, symptomatic DVT rate or symptomatic PE rate. The symptomatic VTE rate was 0.5% (11/2,166) in the LMWH group versus 0.6% (10/1,713) in the control group. Although the limitations of this meta-analysis cannot be ignored, the results of our study show that LMWH after knee arthroscopy is ineffective. We recommend that LMWH should not be routinely provided for knee arthroscopy. TRIAL REGISTRATION: ClinicalTrials.gov NCT03164746.


Assuntos
Artroscopia/efeitos adversos , Heparina de Baixo Peso Molecular/efeitos adversos , Heparina de Baixo Peso Molecular/farmacologia , Joelho/cirurgia , Segurança , Humanos , Tromboembolia Venosa/etiologia , Tromboembolia Venosa/prevenção & controle
4.
Orthop Surg ; 9(2): 186-190, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28557297

RESUMO

OBJECTIVES: The relationship between cup inclination angle and liner wear is controversial. Most authors in the published literature agree that the ideal cup inclination is associated with lower inner wear; however, some disagree. All previous studies did not control for femoral head diameter and inclination, so it is difficult to assess the relative or synergistic effects of cup angle on outcomes. METHODS: We retrospectively reviewed 154 patients (171 hips) with primary total hip arthroplasties performed from 2001 to 2004. All surgeries had been performed by the same physician team. A posterior approach was applied in all patients. All prostheses were non-cemented cups with a 28-mm metal head. Inclusion criteria included that the radiographic material was not completed or lost for primary or last follow up. Patients were divided into four groups according to different cup inclination angle. There were 108 hips with inclination angles below 50°; 35 hips with angles between 50° and 55°; 17 hips with angles between 55° and 60°; and 11 hips with angles greater than 60°. An immediate postoperative radiograph was compared with a follow-up radiograph. Clinical and radiographic data were collected on standardized hip evaluation forms preoperatively, 6 months after surgery and at yearly follow-up visits. Radiographs were digitized and enlarged 100%. After the radiographs were digitized, polyethylene wear rates and acetabular cup abduction were measured on all patients with Cavas 15.0 software. The results were analyzed using Student's two-tailed paired t-test with SPSS 11.5. RESULTS: The preoperative mean Harris hip score improved from 45.36 to 93.5 points 10 years after surgery. No acetabular component was revised for aseptic loosening. Three patients (three hips) had to undergo bone grafting and a lined arthroplasty for severe osteolysis around the acetabular component. The rate of implant survival at 10 years with respect to loosening was 100%. The mean liner wear rate was 0.135 mm/year in cups with inclination angles below 50°, 0.144 mm/year between 50° and 55°, 0.260 mm/year between 55° and 60°, and 0.403 mm/year when the angle was greater than 60°. Liner wear increased when the cup angle was larger than 55° (P < 0.05). CONCLUSIONS: For metal-on-polyethylene prostheses, liner wear correlates with cup inclination angle larger than 55°. The ideal abduction angle for metal-on-polyethylene prostheses is less than 55°.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Artrite/cirurgia , Feminino , Necrose da Cabeça do Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno/uso terapêutico , Desenho de Prótese , Falha de Prótese , Radiografia , Estudos Retrospectivos
5.
Chin Med J (Engl) ; 129(4): 386-91, 2016 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-26879010

RESUMO

BACKGROUND: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA). This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee. METHODS: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method. In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation. TSG cases were treated with the conventional method. Outcomes were obtained from the postoperative image examination and short-term follow-up. RESULTS: Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG. The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively. The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG. Statistically significant differences were found between GPG and TSG in all measurements. CONCLUSIONS: A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images. This allows for shorter operative times and better postoperative alignment than the traditional surgery. Application of the digital guide plate may also result in better short-term outcomes.


Assuntos
Artroplastia do Joelho/métodos , Joelho/diagnóstico por imagem , Osteotomia/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Chin J Traumatol ; 17(6): 331-4, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25471427

RESUMO

OBJECTIVE: To study retrospectively 20 hip revison patients treated by cementless total hip arthroplasty with structural allograft. METHODS: Twenty patients suffering from aseptic loosening of an uncemented cup complicated by a large defect underwent cementless total hip arthroplasty with structural allograft and were followed up for at least 5 years. Clinical results were evaluated by Harris score and leg length measurements. Radiographic analysis included implants migration, graft absorbance, osteolysis and liner wear. RESULTS: No cup loosening or graft reabsorption was found at final follow-up. Clinical improvements in pain and functional status were demonstrated during the follow-up period. The mean Harris hip scores improved from 29 preoperatively (range 20-41) to 81 postoperatively (range 73-89). CONCLUSION: Our study shows that cementless total hip arthroplasty with allograft is a good way for massive defect in acetabular bone stock.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Aloenxertos , Seguimentos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA