Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 47(5): 704-712, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37707399

RESUMO

OBJECTIVE: This study used metal artifact reduction (MAR) software to examine the computed tomography (CT) number of dual-energy CT (DECT) of hepatocellular carcinoma after transcatheter arterial chemoembolization. METHODS: Hollow columnar acrylic phantoms were filled with lipiodol and inserts of 2 sizes (large and small) were used to simulate liver tumors on a Revolution GSI CT scanner. The CT numbers of a single test object were collected twice: once with and once without the MAR algorithm. Lipiodol beam-hardening artifacts were quantified by measuring CT numbers in a region of interest around the tumor-simulating insert. RESULTS: The virtual monochromatic CT numbers of large and small tumors were closely related to energy. For small tumors, CT numbers increased with energy. For large tumors, CT numbers increased with energy at 1 cm from the margin but decreased with an increase in energy at 5 cm. Regardless of the size, distance, or location of the tumor, the CT numbers fluctuated more at low energy levels. CONCLUSIONS: At 1 cm from the margin, the CT numbers with MAR were significantly different from those without MAR. Low-energy CT numbers with MAR were near reference values. Metal artifact reduction exhibited superior performance for small tumors. Tumor margin images are affected by artifacts caused by Lipiodol. However, with MAR, CT numbers can be effectively calibrated, thus enabling clinicians to more accurately evaluate hepatocellular carcinoma development and identify residual tumors and recurrent or metastatic lesions.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Óleo Etiodado , Artefatos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Metais , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Imagens de Fantasmas
2.
Health Phys ; 123(4): 287-294, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35951348

RESUMO

ABSTRACT: The objective of this paper is to validate virtual monochromatic computed tomography (CT) numbers and the effect of the body size of insert materials in phantoms on the findings of a dual-energy CT scanner. The material inserted in the phantom simulates human organs. This study investigated the effect of different body sizes on CT numbers to understand the accuracy of dual-energy CT. The effect of body size on virtual monochromatic CT numbers was investigated using a QRM phantom. The true monochromatic CT numbers of insert materials were calculated from coefficients obtained using NIST XCOM. The true Z eff values were supplied by phantom manufacturers or computed using Mayneord's equation. The virtual monochromatic CT numbers of insert materials in both the phantoms varied with energy. The CT numbers of materials with a Z eff of >7.42 (water Z eff ) and <7.42 decreased and increased with energy, respectively. The CT numbers were affected by phantom size as a function of energy. For water, tissues, and air, the CT numbers in the XL phantom were considerably larger than those in other phantom sizes at 40 keV. Body size affected the CT numbers, particularly for the XL size and at low energies. For all materials, the magnitude of difference between the measured and true CT numbers was related to the Z eff of the materials, potentially because the photoelectric effect is more prominent at low energies for materials with a higher Z eff . The difference in CT numbers appeared to be dependent on position. The true and measured Z eff agreed to within 6% for all the materials except the SR2 brain, for which the discrepancy was 25%.


Assuntos
Tomografia Computadorizada por Raios X , Água , Tamanho Corporal , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA