Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 11(5)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38790303

RESUMO

The production of biomedical devices able to appropriately interact with the biological environment is still a great challenge. Synthetic materials are often employed, but they fail to replicate the biological and functional properties of native tissues, leading to a variety of adverse effects. Several commercial products are based on chemically treated xenogeneic tissues: their principal drawback is due to weak mechanical stability and low durability. Recently, decellularization has been proposed to bypass the drawbacks of both synthetic and biological materials. Acellular materials can integrate with host tissues avoiding/mitigating any foreign body response, but they often lack sufficient patency and impermeability. The present paper investigates an innovative approach to the realization of hybrid materials that combine decellularized bovine pericardium with polycarbonate urethanes. These hybrid materials benefit from the superior biocompatibility of the biological tissue and the mechanical properties of the synthetic polymers. They were assessed from physicochemical, structural, mechanical, and biological points of view; their ability to promote cell growth was also investigated. The decellularized pericardium and the polymer appeared to well adhere to each other, and the two sides were distinguishable. The maximum elongation of hybrid materials was mainly affected by the pericardium, which allows for lower elongation than the polymer; this latter, in turn, influenced the maximum strength achieved. The results confirmed the promising features of hybrid materials for the production of vascular grafts able to be repopulated by circulating cells, thus, improving blood compatibility.

2.
J Biomed Mater Res A ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783716

RESUMO

Population aging, reduced economic capacity, and neglecting the treatments for oral pathologies, are the main causal factors for about 3 billion individuals who are suffering from partial/total edentulism or alveolar bone resorption: thus, the demand for dental implants is increasingly growing. To achieve a good prognosis for implant-supported restorations, adequate peri-implant bone volume is mandatory. The Guided Bone Regeneration (GBR) technique is one of the most applied methods for alveolar bone reconstruction and treatment of peri-implant bone deficiencies. This technique involves the use of different types of membranes in association with some bone substitutes (autologous, homologous, or heterologous). However, time for bone regeneration is often too long and the bone quality is not simply predictable. This study aims at engineering and evaluating the efficacy of modified barrier membranes, enhancing their bioactivity for improved alveolar bone tissue regeneration. We investigated membranes functionalized with chitosan (CS) and chitosan combined with the peptide GBMP1α (CS + GBMP1α), to improve bone growth. OsseoGuard® membranes, derived from bovine Achilles tendon type I collagen crosslinked with formaldehyde, were modified using CS and CS + GBMP1α. The functionalization, carried out with 1-ethyl-3-(3 dimethylaminopropyl)carbodiimide and sulfo-N-Hydroxysuccinimide (EDC/sulfo-NHS), was assessed through FT-IR and XPS analyses. Biological assays were performed by directly seeding human osteoblasts onto the materials to assess cell proliferation, mineralization, gene expression of Secreted Phosphoprotein 1 (SPP1) and Runt-Related Transcription Factor 2 (Runx2), and antibacterial properties. Both CS and CS + GBMP1α functionalizations significantly enhanced human osteoblast proliferation, mineralization, gene expression, and antibacterial activity compared to commercial membranes. The CS + GBMP1α functionalization exhibited superior outcomes in all biological assays. Mechanical tests showed no significant alterations of membrane biomechanical properties post-functionalization. The engineered membranes, especially those functionalized with CS + GBMP1α, are suitable for GBR applications thanks to their ability to enhance osteoblast activity and promote bone tissue regeneration. These findings suggest a potential advancement in the treatment of oral cavity problems requiring bone regeneration.

3.
J Funct Biomater ; 14(3)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36976065

RESUMO

Conduit substitutes are increasingly in demand for cardiovascular and urological applications. In cases of bladder cancer, radical cystectomy is the preferred technique: after removing the bladder, a urinary diversion has to be created using autologous bowel, but several complications are associated with intestinal resection. Thus, alternative urinary substitutes are required to avoid autologous intestinal use, preventing complications and facilitating surgical procedures. In the present paper, we are proposing the exploitation of the decellularized porcine descending aorta as a novel and original conduit substitute. After being decellularized with the use of two alternative detergents (Tergitol and Ecosurf) and sterilized, the porcine descending aorta has been investigated to assess its permeability to detergents through methylene blue dye penetration analysis and to study its composition and structure by means of histomorphometric analyses, including DNA quantification, histology, two-photon microscopy, and hydroxyproline quantification. Biomechanical tests and cytocompatibility assays with human mesenchymal stem cells have been also performed. The results obtained demonstrated that the decellularized porcine descending aorta preserves its major features to be further evaluated as a candidate material for urological applications, even though further studies have to be carried out to demonstrate its suitability for the specific application, by performing in vivo tests in the animal model.

4.
Polymers (Basel) ; 15(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36850103

RESUMO

Right ventricle outflow tract obstruction (RVOTO) is a congenital pathological condition that contributes to about 15% of congenital heart diseases. In most cases, the replacement of the right ventricle outflow in pediatric age requires subsequent pulmonary valve replacement in adulthood. The aim of this study was to investigate the extracellular matrix scaffold obtained by decellularization of the porcine pulmonary valve using a new detergent (Tergitol) instead of Triton X-100. The decellularized scaffold was evaluated for the integrity of its extracellular matrix (ECM) structure by testing for its biochemical and mechanical properties, and the cytotoxicity/cytocompatibility of decellularized tissue was assessed using bone marrow-derived mesenchymal stem cells. We concluded that Tergitol could remove the nuclear material efficiently while preserving the structural proteins of the matrix, but without an efficient removal of the alpha-gal antigenic epitope. Therefore, Tergitol can be used as an alternative detergent to replace the Triton X-100.

5.
Int J Mol Sci ; 24(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36769254

RESUMO

The covalent functionalization of synthetic peptides allows the modification of different biomaterials (metallic, polymeric, and ceramic), which are enriched with biologically active sequences to guide cell behavior. Recently, this strategy has also been applied to decellularized biological matrices. In this study, the covalent anchorage of a synthetic peptide (REDV) to a pericardial matrix decellularized via Schiff base is realized starting from concentrated peptide solutions (10-4 M and 10-3 M). The use of a labeled peptide demonstrated that as the concentration of the working solution increased, the surface density of the anchored peptide increased as well. These data are essential to pinpointing the concentration window in which the peptide promotes the desired cellular activity. The matrices were extensively characterized by Water Contact Angle (WCA) analysis, Differential Scanning Calorimetry (DSC) analysis, geometric feature evaluation, biomechanical tests, and preliminary in vitro bioassays.


Assuntos
Peptídeos , Pericárdio , Materiais Biocompatíveis
6.
Life (Basel) ; 14(1)2023 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-38255682

RESUMO

Urinary incontinence is still an underestimated problem due to its anatomical complexity and social taboo. Most of the time, it is believed to affect predominantly the elderly female population, and the literature still lacks data on its presence in the younger and male populations. Its relationship with other pelvic floor dysfunctions (PFDs) and sport activity remains an open topic. Thus, the present study surveyed 342 subjects of both genders, ranging from 18 to 39 y/o and with different sport activity levels, to understand the prevalence of PFDs (such as haemorrhoids, anal fissures, involuntary urinary/faecal leakage, and urgency). The results also showed a significative prevalence in younger, sporty, and male people. Approximately one third of the population had urinary incontinence mostly during stress activities (sport activity: 17%, cough/sneeze: 13%). The statistical analysis confirmed a higher prevalence in the cases of a light (32%) and intense (41%) sport activity level and a protective role of sport if practiced between 5 and 10 h/week, with bodybuilding/CrossFit and running seeming to be the riskiest sports. The relationship with the other PFDs showed a statistically significant dependence with most of them, confirming that urinary incontinence cannot be considered a separate problem from the other PFDs.

7.
Front Bioeng Biotechnol ; 10: 1042434, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36578513

RESUMO

Structural cardiac lesions are often surgically repaired using prosthetic patches, which can be biological or synthetic. In the current clinical scenario, biological patches derived from the decellularization of a xenogeneic scaffold are gaining more interest as they maintain the natural architecture of the extracellular matrix (ECM) after the removal of the native cells and remnants. Once implanted in the host, these patches can induce tissue regeneration and repair, encouraging angiogenesis, migration, proliferation, and host cell differentiation. Lastly, decellularized xenogeneic patches undergo cell repopulation, thus reducing host immuno-mediated response against the graft and preventing device failure. Porcine small intestinal submucosa (pSIS) showed such properties in alternative clinical scenarios. Specifically, the US FDA approved its use in humans for urogenital procedures such as hernia repair, cystoplasties, ureteral reconstructions, stress incontinence, Peyronie's disease, penile chordee, and even urethral reconstruction for hypospadias and strictures. In addition, it has also been successfully used for skeletal muscle tissue reconstruction in young patients. However, for cardiovascular applications, the results are controversial. In this study, we aimed to validate our decellularization protocol for SIS, which is based on the use of Tergitol 15 S 9, by comparing it to our previous and efficient method (Triton X 100), which is not more available in the market. For both treatments, we evaluated the preservation of the ECM ultrastructure, biomechanical features, biocompatibility, and final bioinductive capabilities. The overall analysis shows that the SIS tissue is macroscopically distinguishable into two regions, one smooth and one wrinkle, equivalent to the ultrastructure and biochemical and proteomic profile. Furthermore, Tergitol 15 S 9 treatment does not modify tissue biomechanics, resulting in comparable to the native one and confirming the superior preservation of the collagen fibers. In summary, the present study showed that the SIS decellularized with Tergitol 15 S 9 guarantees higher performances, compared to the Triton X 100 method, in all the explored fields and for both SIS regions: smooth and wrinkle.

8.
J Funct Biomater ; 13(4)2022 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-36412863

RESUMO

Among the urinary tract's malignancies, bladder cancer is the most frequent one: it is at the tenth position of most common cancers worldwide. Currently, the gold standard therapy consists of radical cystectomy, which results in the need to create a urinary diversion using a bowel segment from the patient. Nevertheless, due to several complications associated with bowel resection and anastomosis, which significantly affect patient quality of life, it is becoming extremely important to find an alternative solution. In our recent work, we proposed the decellularized porcine small intestinal submucosa (SIS) as a candidate material for urinary conduit substitution. In the present study, we create SIS-based hybrid membranes that are obtained by coupling decellularized SIS with two commercially available polycarbonate urethanes (Chronoflex AR and Chronoflex AR-LT) to improve SIS mechanical resistance and impermeability. We evaluated the hybrid membranes by means of immunofluorescence, two-photon microscopy, FTIR analysis, and mechanical and cytocompatibility tests. The realization of hybrid membranes did not deteriorate SIS composition, but the presence of polymers ameliorates the mechanical behavior of the hybrid constructs. Moreover, the cytocompatibility tests demonstrated a significant increase in cell growth compared to decellularized SIS alone. In light of the present results, the hybrid membrane-based urinary conduit can be a suitable candidate to realize a urinary diversion in place of an autologous intestinal segment. Further efforts will be performed in order to create a cylindrical-shaped hybrid membrane and to study its hydraulic behavior.

9.
Cells ; 11(19)2022 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-36230907

RESUMO

Esophageal reconstruction through bio-engineered allografts that highly resemble the peculiar properties of the tissue extracellular matrix (ECM) is a prospective strategy to overcome the limitations of current surgical approaches. In this work, human esophagus was decellularized for the first time in the literature by comparing three detergent-enzymatic protocols. After decellularization, residual DNA quantification and histological analyses showed that all protocols efficiently removed cells, DNA (<50 ng/mg of tissue) and muscle fibers, preserving collagen/elastin components. The glycosaminoglycan fraction was maintained (70-98%) in the decellularized versus native tissues, while immunohistochemistry showed unchanged expression of specific ECM markers (collagen IV, laminin). The proteomic signature of acellular esophagi corroborated the retention of structural collagens, basement membrane and matrix-cell interaction proteins. Conversely, decellularization led to the loss of HLA-DR expression, producing non-immunogenic allografts. According to hydroxyproline quantification, matrix collagen was preserved (2-6 µg/mg of tissue) after decellularization, while Second-Harmonic Generation imaging highlighted a decrease in collagen intensity. Based on uniaxial tensile tests, decellularization affected tissue stiffness, but sample integrity/manipulability was still maintained. Finally, the cytotoxicity test revealed that no harmful remnants/contaminants were present on acellular esophageal matrices, suggesting allograft biosafety. Despite the different outcomes showed by the three decellularization methods (regarding, for example, tissue manipulability, DNA removal, and glycosaminoglycans/hydroxyproline contents) the ultimate validation should be provided by future repopulation tests and in vivo orthotopic implant of esophageal scaffolds.


Assuntos
Detergentes , Elastina , Colágeno , DNA/metabolismo , Esôfago/metabolismo , Glicosaminoglicanos/metabolismo , Humanos , Hidroxiprolina , Laminina , Proteômica
10.
Front Bioeng Biotechnol ; 10: 912617, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36267444

RESUMO

Current surgical options for patients requiring esophageal replacement suffer from several limitations and do not assure a satisfactory quality of life. Tissue engineering techniques for the creation of customized "self-developing" esophageal substitutes, which are obtained by seeding autologous cells on artificial or natural scaffolds, allow simplifying surgical procedures and achieving good clinical outcomes. In this context, an appealing approach is based on the exploitation of decellularized tissues as biological matrices to be colonized by the appropriate cell types to regenerate the desired organs. With specific regard to the esophagus, the presence of a thick connective texture in the decellularized scaffold hampers an adequate penetration and spatial distribution of cells. In the present work, the Quantum Molecular Resonance® (QMR) technology was used to create a regular microchannel structure inside the connective tissue of full-thickness decellularized tubular porcine esophagi to facilitate a diffuse and uniform spreading of seeded mesenchymal stromal cells within the scaffold. Esophageal samples were thoroughly characterized before and after decellularization and microperforation in terms of residual DNA content, matrix composition, structure and biomechanical features. The scaffold was seeded with mesenchymal stromal cells under dynamic conditions, to assess the ability to be repopulated before its implantation in a large animal model. At the end of the procedure, they resemble the original esophagus, preserving the characteristic multilayer composition and maintaining biomechanical properties adequate for surgery. After the sacrifice we had histological and immunohistochemical evidence of the full-thickness regeneration of the esophageal wall, resembling the native organ. These results suggest the QMR microperforated decellularized esophageal scaffold as a promising device for esophagus regeneration in patients needing esophageal substitution.

11.
Biomimetics (Basel) ; 7(3)2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35997424

RESUMO

Human and animal pericardia are among the most widely exploited materials suitable to repair damaged tissues in the cardiovascular surgery context. Autologous, xenogeneic (chemically treated) and homologous pericardia are largely utilized, but they do exhibit some crucial drawbacks. Any tissue treated with glutaraldehyde is known to be prone to calcification in vivo, lacks regeneration potential, has limited durability, and can result in cytotoxicity. Moreover, autologous tissues have limited availability. Decellularized biological tissues represent a promising alternative: decellularization removes cellular and nuclear components from native tissues and makes them suitable for repopulation by autologous cells upon implantation into the body. The present work aims to assess the effects of a new detergent, i.e., Tergitol, for decellularizing bovine and porcine pericardia. The decellularization procedure successfully removed cells, while preserving the histoarchitecture of the extracellular matrix. No cytotoxic effect was observed. Therefore, decellularized pericardia showed potential to be used as scaffold for cardiovascular tissue regeneration.

12.
Int J Mol Sci ; 23(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35269969

RESUMO

Bladder cancer (BC) is among the most common malignancies in the world and a relevant cause of cancer mortality. BC is one of the most frequent causes for bladder removal through radical cystectomy, the gold-standard treatment for localized muscle-invasive and some cases of high-risk, non-muscle-invasive bladder cancer. In order to restore urinary functionality, an autologous intestinal segment has to be used to create a urinary diversion. However, several complications are associated with bowel-tract removal, affecting patients' quality of life. The present study project aims to develop a bio-engineered material to simplify this surgical procedure, avoiding related surgical complications and improving patients' quality of life. The main novelty of such a therapeutic approach is the decellularization of a porcine small intestinal submucosa (SIS) conduit to replace the autologous intestinal segment currently used as urinary diversion after radical cystectomy, while avoiding an immune rejection. Here, we performed a preliminary evaluation of this acellular product by developing a novel decellularization process based on an environmentally friendly, mild detergent, i.e., Tergitol, to replace the recently declared toxic Triton X-100. Treatment efficacy was evaluated through histology, DNA, hydroxyproline and elastin quantification, mechanical and insufflation tests, two-photon microscopy, FTIR analysis, and cytocompatibility tests. The optimized decellularization protocol is effective in removing cells, including DNA content, from the porcine SIS, while preserving the integrity of the extracellular matrix despite an increase in stiffness. An effective sterilization protocol was found, and cytocompatibility of treated SIS was demonstrated from day 1 to day 7, during which human fibroblasts were able to increase in number and strongly organize along tissue fibres. Taken together, this in vitro study suggests that SIS is a suitable candidate for use in urinary diversions in place of autologous intestinal segments, considering the optimal results of decellularization and cell proliferation. Further efforts should be undertaken in order to improve SIS conduit patency and impermeability to realize a future viable substitute.


Assuntos
Neoplasias da Bexiga Urinária , Animais , DNA , Humanos , Mucosa Intestinal , Intestino Delgado , Qualidade de Vida , Suínos , Engenharia Tecidual/métodos , Neoplasias da Bexiga Urinária/cirurgia
13.
Polymers (Basel) ; 14(6)2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35335556

RESUMO

The most common aortic valve diseases in adults are stenosis due to calcification and regurgitation. In pediatric patients, aortic pathologies are less common. When a native valve is surgically replaced by a prosthetic one, it is necessary to consider that the latter has a limited durability. In particular, current bioprosthetic valves have to be replaced after approximately 10 years; mechanical prostheses are more durable but require the administration of permanent anticoagulant therapy. With regard to pediatric patients, both mechanical and biological prosthetic valves have to be replaced due to their inability to follow patients' growth. An alternative surgical substitute can be represented by the acellular porcine aortic valve that exhibits less immunogenic risk and a longer lifespan. In the present study, an efficient protocol for the removal of cells by using detergents, enzyme inhibitors, and hyper- and hypotonic shocks is reported. A new detergent (Tergitol) was applied to replace TX-100 with the aim to reduce toxicity and maximize ECM preservation. The structural integrity and efficient removal of cells and nuclear components were assessed by means of histology, immunofluorescence, and protein quantification; biomechanical properties were also checked by tensile tests. After decellularization, the acellular scaffold was sterilized with a standard protocol and repopulated with bone marrow mesenchymal stem cells to analyze its biocompatibility profile.

14.
Biomater Res ; 25(1): 26, 2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34376256

RESUMO

BACKGROUND: Due to the shortage of organs' donors that limits biological heart transplantations, mechanical circulatory supports can be implanted in case of refractory end-stage heart failure to replace partially (Ventricular Assist Device, VAD) or completely (Total Artificial Heart, TAH) the cardiac function. The hemocompatibility of mechanical circulatory supports is a fundamental issue that has not yet been fully matched; it mostly depends on the nature of blood-contacting surfaces. METHODS: In order to obtain hemocompatible materials, a pool of hybrid membranes was fabricated by coupling a synthetic polymer (polycarbonate urethane, commercially available in two formulations) with a decellularized biological tissue (porcine pericardium). To test their potential suitability as candidate materials for realizing the blood-contacting surfaces of a novel artificial heart, hybrid membranes have been preliminarily characterized in terms of physicochemical, structural and mechanical properties. RESULTS: Our results ascertained that the hybrid membranes are properly stratified, thus allowing to expose their biological side to blood and their polymeric surface to the actuation system of the intended device. From the biomechanical point of view, the hybrid membranes can withstand deformations up to more than 70 % and stresses up to around 8 MPa. CONCLUSIONS: The hybrid membranes are suitable for the construction of the ventricular chambers of innovative mechanical circulatory support devices.

15.
J Mater Sci Mater Med ; 32(8): 86, 2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34313865

RESUMO

Over the years, several devices have been created (and the development of many others is currently in progress) to be in permanent contact with blood: mechanical circulatory supports represent an example thereof. The hemocompatibility of these devices largely depends on the chemical composition of blood-contacting components. In the present work, an innovative material (hybrid membrane) is proposed to fabricate the inner surfaces of a pulsatile ventricular chamber: it has been obtained by coupling a synthetic polymer (e.g., commercial polycarbonate urethane) with decellularized porcine pericardium. The hemocompatibility of the innovative material has been preliminarily assessed by measuring its capacity to promote thrombin generation and induce platelet activation. Our results demonstrated the blood compatibility of the proposed hybrid membrane.


Assuntos
Plaquetas/efeitos dos fármacos , Sangue/efeitos dos fármacos , Materiais Revestidos Biocompatíveis , Membranas Artificiais , Ativação Plaquetária , Adulto , Animais , Sangue/metabolismo , Feminino , Humanos , Teste de Materiais/métodos , Pericárdio/química , Pericárdio/efeitos dos fármacos , Cimento de Policarboxilato/química , Polímeros/química , Estresse Mecânico , Propriedades de Superfície , Suínos , Trombina/química , Uretana/química
16.
Int J Mol Sci ; 22(11)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34072888

RESUMO

Hybrid biomaterials allow for the improvement of the biological properties of materials and have been successfully used for implantology in medical applications. The covalent and selective functionalization of materials with bioactive peptides provides favorable results in tissue engineering by supporting cell attachment to the biomaterial through biochemical cues and interaction with membrane receptors. Since the functionalization with bioactive peptides may alter the chemical and physical properties of the biomaterials, in this study we characterized the biological responses of differently functionalized chitosan analogs. Chitosan analogs were produced through the reaction of GRGDSPK (RGD) or FRHRNRKGY (HVP) sequences, both carrying an aldehyde-terminal group, to chitosan. The bio-functionalized polysaccharides, pure or "diluted" with chitosan, were chemically characterized in depth and evaluated for their antimicrobial activities and biocompatibility toward human primary osteoblast cells. The results obtained indicate that the bio-functionalization of chitosan increases human-osteoblast adhesion (p < 0.005) and proliferation (p < 0.005) as compared with chitosan. Overall, the 1:1 mixture of HVP functionalized-chitosan:chitosan is the best compromise between preserving the antibacterial properties of the material and supporting osteoblast differentiation and calcium deposition (p < 0.005 vs. RGD). In conclusion, our results reported that a selected concentration of HVP supported the biomimetic potential of functionalized chitosan better than RGD and preserved the antibacterial properties of chitosan.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Transplante Ósseo/métodos , Quitosana/química , Osteogênese/efeitos dos fármacos , Engenharia Tecidual , Materiais Biocompatíveis/síntese química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Regeneração Óssea/genética , Osso e Ossos/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Quitosana/análogos & derivados , Quitosana/síntese química , Quitosana/farmacologia , Durapatita/química , Durapatita/farmacologia , Humanos , Oligopeptídeos/síntese química , Oligopeptídeos/química , Osteoblastos/efeitos dos fármacos , Alicerces Teciduais/química
17.
Blood Purif ; 46(3): 196-204, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29886489

RESUMO

BACKGROUND: Inadequate removal of molecules between 5 and 50 KDa may cause long-term complication in chronic hemodialysis. Medium cut-off (MCO) is a new class of membranes with enhanced sieving properties and negligible albumin loss. MCO membrane makes it possible to perform expanded hemodialysis (HDx), a technique based on high internal filtration (IF).The present study is designed to quantify IF in 2 MCO dialyzers (Theranova 400 and 500, Baxter, Deerfield, USA) using a nuclear imaging technique previously validated. METHODS: Blood and dialysate compartment pressure drop along with transmembrane pressure; they were measured in a closed in vitro circuit with human blood (blood flow [QB] = 300 and 400 mL/min; dialysate flow 500 mL/min; net ultrafiltration rate 0 mL/min). A non-diffusible marker molecule (albumin macro-aggregates labeled with 99Tc metastable) was injected in the blood compartment and nuclear emission was recorded by a gamma camera. Relative variations in the concentration of the marker molecule along the length of the filter were used to calculate local cross filtration. RESULTS: Based on marker concentration profiles, IF was estimated. For Theranova 400, IF were 29.7 and 41.6 mL/min for QB of 300 and 400 mL/min. For Theranova 500, IF were 31.6 and 53.1 mL/min for QB of 300 and 400 mL/min respectively. CONCLUSIONS: MCO membrane provides significant amounts of IF due to the particular combination between hydraulic permeability of the membrane and reduced inner diameter of the fibers. High IF combined with enhanced sieving profile of MCO membrane leads to improved removal of a wider spectrum of uremia retention molecules in HDx, without requiring complex equipment.


Assuntos
Membranas Artificiais , Diálise Renal/instrumentação , Filtração , Humanos , Diálise Renal/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA