Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 203
Filtrar
1.
J Appl Clin Med Phys ; 25(5): e14344, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38615273

RESUMO

PURPOSE: Radiotherapy (RT) treatment and treatment planning is a complex process prepared and delivered by a multidisciplinary team of specialists. Efficient communication and notification systems among different team members are therefore essential to ensure the safe, timely delivery of treatments to patients. METHOD: To address this issue, we developed and implemented automated notification systems and an electronic whiteboard to track every CT simulation, contouring task, the new-start schedule, and physician's appointments and tasks, and notify team members of overdue and missing tasks and appointments. The electronic whiteboard was developed to have a straightforward view of current patients' planning workflow and to help different team members coordinate with each other. The systems were implemented and have been used at our center to monitor the progress of treatment-planning tasks for over 2 years. RESULTS: The last-minute plans were relatively reduced by about 40% in 2023 compared to 2021 and 2022 with a p-value < 0.05. The overdue contouring tasks of more than 1 day decreased from 46.8% in 2019 and 33.6% in 2020 to 20%-26.4% in 2021-2023 with a p-value < 0.05 after the implementation of the notification system. The rate of plans with 1-3 day planning time decreased by 20.31%, 39.32%, and 24.08% with a p-value < 0.05 and the rate of plans with 1-3 day planning time due to the contouring task overdue more than 1 day decreased by 49.49%, 56.89%, and 46.52% with a p-value < 0.05 after the implementation. The rate of outstanding appointments that are overdue by more than 7 days decreased by more than 5% with a p-value < 0.05 following the implementation of the system. CONCLUSIONS: Our experience shows that this system requires minimal human intervention, improves the treatment planning workflow and process by reducing errors and delays in the treatment planning process, positively impacts on-time treatment plan completion, and reduces the need for compressed or rushed treatment planning timelines.


Assuntos
Neoplasias , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias/radioterapia , Radioterapia de Intensidade Modulada/métodos , Fluxo de Trabalho , Tomografia Computadorizada por Raios X/métodos
2.
ArXiv ; 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38168461

RESUMO

We investigated cellular distribution of a tumor-specific gadolinium chelate in 4T1 and U87 cancer cells with the goal to generate more realistic geometries for Monte Carlo simulations of radiation interaction with nanoparticles in cells. Cells were exposed to the agent in-vitro for 30 minutes to 72 hours before being fixed and imaged using transmission electron microscopy. Initially, electron-dense areas consistent with gadolinium were observable throughout the cytoplasm. At six hours those areas were restricted to endosomes and at 24 hours or longer electron dense areas were only found in lysosomes. Lysosomes were on average larger in 4T1 cells, which were exposed to 1 mM concentration compared to U87 cells, exposed to 1 uM. Based on this information we built an extended cell model for Monte Carlo simulations that includes lysosomes with discrete nanoparticle enclaves in addition to mitochondria and the nucleus.

4.
Front Oncol ; 13: 1276766, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37941541

RESUMO

Background: The incidence of bilateral breast cancer (BBC) ranges from 1.4% to 11.8%. BBC irradiation is a challenge in current clinical practice due to the large target volume that must be irradiated while minimizing the dose to critical organs. Supine or prone breast techniques can be used, with the latter providing better organ sparing; both, however, result in lengthy treatment times. The use of Intra-operative radiotherapy (IORT) in breast cancer patients who choose breast conservation has been highlighted in previous studies, but there is a scarcity of literature analyzing the utility and applicability of IORT in BBC. This case series aims to highlight the applicability of administering bilateral IORT in patients with BBC. Case reports: Five patients with bilateral early-stage breast cancer (or DCIS) were treated with breast-conserving surgery followed by bilateral IORT. Of the 10 breast cancers, 8 were diagnosed as either DCIS or IDC, while the other 2 were diagnosed as invasive lobular carcinoma and invasive carcinoma, respectively. During surgery, all patients received bilateral IORT. Furthermore, 1 patient received external beam radiation therapy after her final pathology revealed grade 3 DCIS. The IORT procedure was well tolerated by all five patients, and all patients received aromatase inhibitors as adjuvant therapy. Additionally, none of these patients showed evidence of disease after a 36-month median follow-up. Conclusion: Our findings demonstrate the successful use of IORT for BCS in patients with BBC. Furthermore, none of the patients in our study experienced any complications, suggesting the feasibility of the use of IORT in BBC. Considering the benefits of improved patient compliance and a reduced number of multiple visits, IORT may serve as an excellent patient-centered alternative for BBC. Future studies are recommended to reinforce the applicability of IORT in patients with BBC.

5.
Radiat Oncol ; 18(1): 123, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491260

RESUMO

BACKGROUND/OBJECTIVE: Intra-operative radiation therapy (IORT) is a newer partial breast irradiation technique that has been well studied in 2 large randomized trials, the TARGIT-A and ELIOT trials. We initiated our IORT program in 2018 in the context of a registry trial, and aim to report our early results thus far. METHODS: We instituted an IORT practice using Intrabeam® low energy 50kVp x-rays for selected breast cancer cases in 2018. Patients were enrolled on our institutional registry protocol which allowed for IORT in ER + patients with grade 1-2 DCIS ≤ 2.5 cm or invasive disease ≤ 3.5 cm in patients of at least 45 years of age. RESULTS: Between January 2018 and December 2021, 181 patients with clinical stage 0-IIA ER + breast cancer were evaluated. One hundred sixty-seven patients ultimately received IORT to 172 sites. The majority of patients received IORT at the time of initial diagnosis and surgery (160/167; 95.8%). Re-excision post IORT occurred in 16/167 patients (9.6%) due to positive margins. Adjuvant RT to the whole breast +/- LN was ultimately given to 23/167 (13.8%) patients mainly due to positive sentinel LN found on final pathology (12/23; 52%); other reasons were close margins for DCIS (3/23; 13%), tumor size (3/23; 4.3%), and multifactorial (5/23; 17.4%). Five patients (3%) had post-operative complications of wound dehiscence. There were 3 local recurrences (1.6%) at a median follow-up of 27.9 months (range: 0.7- 54.8 months). CONCLUSIONS: IORT has been proven to be a safe and patient-centered form of local adjuvant RT for our population, in whom compliance with a longer course of external beam radiation can be an issue. Long term efficacy remains to be evaluated through continued follow up. In the era of COVID-19 and beyond, IORT has been an increasingly attractive option, as it greatly minimizes toxicities and patient visits to the clinic. TRIAL REGISTRATION: All patients were prospectively enrolled on an institutional review board-approved registry trial (IRB number: 2018-9409).


Assuntos
Neoplasias da Mama , COVID-19 , Carcinoma Intraductal não Infiltrante , Feminino , Humanos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Cuidados Intraoperatórios , Mastectomia Segmentar/métodos , Recidiva Local de Neoplasia/cirurgia , Pessoa de Meia-Idade
6.
Int J Radiat Oncol Biol Phys ; 117(3): 571-580, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37150264

RESUMO

PURPOSE: Initial report of NRG Oncology CC001, a phase 3 trial of whole-brain radiation therapy plus memantine (WBRT + memantine) with or without hippocampal avoidance (HA), demonstrated neuroprotective effects of HA with a median follow-up of fewer than 8 months. Herein, we report the final results with complete cognition, patient-reported outcomes, and longer-term follow-up exceeding 1 year. METHODS AND MATERIALS: Adult patients with brain metastases were randomized to HA-WBRT + memantine or WBRT + memantine. The primary endpoint was time to cognitive function failure, defined as decline using the reliable change index on the Hopkins Verbal Learning Test-Revised (HVLT-R), Controlled Oral Word Association, or the Trail Making Tests (TMT) A and B. Patient-reported symptom burden was assessed using the MD Anderson Symptom Inventory with Brain Tumor Module and EQ-5D-5L. RESULTS: Between July 2015 and March 2018, 518 patients were randomized. The median follow-up for living patients was 12.1 months. The addition of HA to WBRT + memantine prevented cognitive failure (adjusted hazard ratio, 0.74, P = .016) and was associated with less deterioration in TMT-B at 4 months (P = .012) and HVLT-R recognition at 4 (P = .055) and 6 months (P = .011). Longitudinal modeling of imputed data showed better preservation of all HVLT-R domains (P < .005). Patients who received HA-WBRT + Memantine reported less symptom burden at 6 (P < .001 using imputed data) and 12 months (P = .026 using complete-case data; P < .001 using imputed data), less symptom interference at 6 (P = .003 using complete-case data; P = .0016 using imputed data) and 12 months (P = .0027 using complete-case data; P = .0014 using imputed data), and fewer cognitive symptoms over time (P = .043 using imputed data). Treatment arms did not differ significantly in overall survival, intracranial progression-free survival, or toxicity. CONCLUSIONS: With median follow-up exceeding 1 year, HA during WBRT + memantine for brain metastases leads to sustained preservation of cognitive function and continued prevention of patient-reported neurologic symptoms, symptom interference, and cognitive symptoms with no difference in survival or toxicity.


Assuntos
Neoplasias Encefálicas , Adulto , Humanos , Neoplasias Encefálicas/secundário , Memantina/uso terapêutico , Irradiação Craniana/efeitos adversos , Irradiação Craniana/métodos , Cognição/efeitos da radiação , Encéfalo , Hipocampo
7.
Med Phys ; 50(7): 4533-4545, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37198998

RESUMO

BACKGROUND: Several studies have shown pencil beam scanning (PBS) proton therapy is a feasible and safe modality to deliver conformal and ultra-high dose rate (UHDR) FLASH radiation therapy. However, it would be challenging and burdensome to conduct the quality assurance (QA) of the dose rate along with conventional patient-specific QA (psQA). PURPOSE: To demonstrate a novel measurement-based psQA program for UHDR PBS proton transmission FLASH radiotherapy (FLASH-RT) using a high spatiotemporal resolution 2D strip ionization chamber array (SICA). METHODS: The SICA is a newly designed open-air strip-segmented parallel plate ionization chamber, which is capable of measuring spot position and profile through 2 mm-spacing-strip electrodes at a 20 kHz sampling rate (50 µs per event) and has been characterized to exhibit excellent dose and dose rate linearity under UHDR conditions. A SICA-based delivery log was collected for each irradiation containing the measured position, size, dwell time, and delivered MU for each planned spot. Such spot-level information was compared with the corresponding quantities in the treatment planning system (TPS). The dose and dose rate distributions were reconstructed on patient CT using the measured SICA log and compared to the planned values in volume histograms and 3D gamma analysis. Furthermore, the 2D dose and dose rate measurements were compared with the TPS calculations of the same depth. In addition, simulations using different machine-delivery uncertainties were performed, and QA tolerances were deduced. RESULTS: A transmission proton plan of 250 MeV for a lung lesion was planned and measured in a dedicated ProBeam research beamline (Varian Medical System) with a nozzle beam current between 100 to 215 nA. The worst gamma passing rates for dose and dose rate of the 2D SICA measurements (four fields) compared to TPS prediction (3%/3 mm criterion) were 96.6% and 98.8%, respectively, whereas the SICA-log reconstructed 3D dose distribution achieved a gamma passing rate of 99.1% (2%/2 mm criterion) compared to TPS. The deviations between SICA measured log, and TPS were within 0.3 ms for spot dwell time with a mean difference of 0.069 ± 0.11 s, within 0.2 mm for spot position with a mean difference of -0.016 ± 0.03 mm in the x-direction, and -0.036 ± 0.059 mm in the y-direction, and within 3% for delivered spot MUs. Volume histogram metric of dose (D95) and dose rate (V40Gy/s ) showed minimal differences, within less than 1%. CONCLUSIONS: This work is the first to describe and validate an all-in-one measurement-based psQA framework that can fulfill the goals of validating the dose rate accuracy in addition to dosimetric accuracy for proton PBS transmission FLASH-RT. The successful implementation of this novel QA program can provide future clinical practice with more confidence in the FLASH application.


Assuntos
Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Prótons , Planejamento da Radioterapia Assistida por Computador
8.
Biomed Phys Eng Express ; 9(4)2023 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-37137293

RESUMO

Nanoparticle-derived radiosensitization has been investigated by several groups using Monte Carlo simulations and biological modeling. In this work we replicated the physical simulation and biological modeling of previously published research for 50 nm gold nanoparticles irradiated with monoenergetic photons, various 250 kVp photon spectra, and spread-out Bragg peak (SOBP) protons. Monte Carlo simulations were performed using TOPAS and used condensed history Penelope low energy physics models for macroscopic dose deposition and interaction with the nanoparticle; simulation of the microscopic dose deposition from nanoparticle secondaries was performed using Geant4-DNA track structure physics. Biological modeling of survival fractions was performed using a local effect model-type approach for MDA-MB-231 breast cancer cells. Physical simulation results agreed extraordinarily well at all distances (1 nm to 10µm from nanoparticle) for monoenergetic photons and SOBP protons in terms of dose per interaction, dose kernel ratio (often labeled dose enhancement factor), and secondary electron spectra. For 250 kVp photons the influence of the gold K-edge was investigated and found to appreciably affect the results. Calculated survival fractions similarly agreed well within one order of magnitude at macroscopic doses (i.e. without nanoparticle contribution) from 1 Gy to 10 Gy. Several 250 kVp spectra were tested to find one yielding closest agreement with previous results. This highlights the importance of a detailed description of the low energy (< 150 keV) component of photon spectra used forin-silico, as well asin-vitro, andin-vivostudies to ensure reproducibility of the experiments by the scientific community. Both, Monte Carlo simulations of physical interactions of the nanoparticle with photons and protons, as well as the biological modelling of cell survival curves agreed extraordinarily well with previously published data. Further investigation of the stochastic nature of nanoparticle radiosenstiziation is ongoing.


Assuntos
Nanopartículas Metálicas , Prótons , Método de Monte Carlo , Ouro/química , Sobrevivência Celular , Reprodutibilidade dos Testes , Nanopartículas Metálicas/química
9.
Med Phys ; 50(7): 4623-4636, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36932693

RESUMO

BACKGROUND: The potential reduction of normal tissue toxicities during FLASH radiotherapy (FLASH-RT) has inspired many efforts to investigate its underlying mechanism and to translate it into the clinic. Such investigations require experimental platforms of FLASH-RT capabilities. PURPOSE: To commission and characterize a 250 MeV proton research beamline with a saturated nozzle monitor ionization chamber for proton FLASH-RT small animal experiments. METHODS: A 2D strip ionization chamber array (SICA) with high spatiotemporal resolution was used to measure spot dwell times under various beam currents and to quantify dose rates for various field sizes. An Advanced Markus chamber and a Faraday cup were irradiated with spot-scanned uniform fields and nozzle currents from 50 to 215 nA to investigate dose scaling relations. The SICA detector was set up upstream to establish a correlation between SICA signal and delivered dose at isocenter to serve as an in vivo dosimeter and monitor the delivered dose rate. Two off-the-shelf brass blocks were used as apertures to shape the dose laterally. Dose profiles in 2D were measured with an amorphous silicon detector array at a low current of 2 nA and validated with Gafchromic films EBT-XD at high currents of up to 215 nA. RESULTS: Spot dwell times become asymptotically constant as a function of the requested beam current at the nozzle of greater than 30 nA due to the saturation of monitor ionization chamber (MIC). With a saturated nozzle MIC, the delivered dose is always greater than the planned dose, but the desired dose can be achieved by scaling the MU of the field. The delivered doses exhibit excellent linearity with R 2 > 0.99 ${R^2} > 0.99$ with respect to MU, beam current, and the product of MU and beam current. If the total number of spots is less than 100 at a nozzle current of 215 nA, a field-averaged dose rate greater than 40 Gy/s can be achieved. The SICA-based in vivo dosimetry system achieved excellent estimates of the delivered dose with an average (maximum) deviation of 0.02 Gy (0.05 Gy) over a range of delivered doses from 3 to 44 Gy. Using brass aperture blocks reduced the 80%-20% penumbra by 64% from 7.55 to 2.75 mm. The 2D dose profiles measured by the Phoenix detector at 2 nA and the EBT-XD film at 215 nA showed great agreement, with a gamma passing rate of 95.99% using 1 mm/2% criterion. CONCLUSION: A 250 MeV proton research beamline was successfully commissioned and characterized. Challenges due to the saturated monitor ionization chamber were mitigated by scaling MU and using an in vivo dosimetry system. A simple aperture system was designed and validated to provide sharp dose fall-off for small animal experiments. This experience can serve as a foundation for other centers interested in implementing FLASH radiotherapy preclinical research, especially those equipped with a similar saturated MIC.


Assuntos
Terapia com Prótons , Prótons , Dosagem Radioterapêutica , Terapia com Prótons/métodos , Síncrotrons , Radiometria
10.
Phys Med Biol ; 68(8)2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36944258

RESUMO

Objective. To investigate the effects of respiratory motion on the delivered dose in the context of proton pencil beam scanning (PBS) transmission FLASH radiotherapy (FLASH-RT) by simulation and phantom measurements.Approach. An in-house simulation code was employed to performin silicosimulation of 2D dose distributions for clinically relevant proton PBS transmission FLASH-RT treatments. A moving simulation grid was introduced to investigate the impacts of various respiratory motion and treatment delivery parameters on the dynamic PBS dose delivery. A strip-ionization chamber array detector and an IROC motion platform were employed to perform phantom measurements of the 2D dose distribution for treatment fields similar to those used for simulation.Main results. Clinically relevant respiratory motion and treatment delivery parameters resulted in degradation of the delivered dose compared to the static delivery as translation and distortion. Simulation showed that the gamma passing rates (2 mm/2% criterion) and target coverage could drop below 50% and 80%, respectively, for certain scenarios if no mitigation strategy was used. The gamma passing rates and target coverage could be restored to more than 95% and 98%, respectively, for short beams delivered at the maximal inhalation or exhalation phase. The simulation results were qualitatively confirmed in phantom measurements with the motion platform.Significance. Respiratory motion could cause dose quality degradation in a clinically relevant proton PBS transmission FLASH-RT treatment if no mitigation strategy is employed, or if an adequate margin is not given to the target. Besides breath-hold, gated delivery can be an alternative motion management strategy to ensure high consistency of the delivered dose while maintaining minimal dose to the surrounding normal tissues. To the best of our knowledge, this is the first study on motion impacts in the context of proton transmission FLASH radiotherapy.


Assuntos
Terapia com Prótons , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Terapia com Prótons/métodos , Simulação por Computador , Imagens de Fantasmas , Dosagem Radioterapêutica
11.
J Appl Clin Med Phys ; 24(4): e13861, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36478148

RESUMO

The purpose of this study is to investigate the dosimetric accuracy of prostate SBRT when motion is considered. To account for target movement, motion compensation and gating techniques were investigated with PTV margins reduced to 2 mm. To allow for dosimetric measurements a Delta4 phantom, Gafchromic film, and Hexamotion motion platform were utilized. Four motion files were utilized that represent a range of motions. Analysis of measured prostate motions for fifteen patients was performed to ensure detected motions were similar to those previously reported and motion files utilized were suitable. Five patient plans were utilized to allow for the effects of MLC and target motion interplay to be investigated. For both motion compensation and gating techniques, plans were delivered to the stationary phantom and for each of four motion types with/without compensation/gating enabled. Using a 3%, 2 mm and 80% threshold gamma criteria, film measurements had an average pass rate of 80.5% for uncorrected deliveries versus 96.0% for motion compensated deliveries. For gated techniques average pass rates increased from 89.9% for uncorrected to 94.8% with gating enabled. Measurements with the Delta4 arrays were analyzed with a 3%, 2 mm and 10% threshold dose. An average pass rate of 83.8% was measured for uncorrected motions versus 94.8% with motion compensation. For the gated technique an average pass rate of 87.2% was found for uncorrected motions versus 96.9% with gating enabled. These results show that very high gamma pass rates are achievable when motion compensation or gating techniques are applied. When target motion is not accounted for shifts up to 5 mm in planned versus delivered isodose distributions were found. However, when motion compensation, or gated techniques were applied, much smaller differences between planned and delivered isodose distributions were found. With these techniques dose delivery accuracy is greatly improved, allowing for PTV margins to be reduced.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Masculino , Humanos , Próstata , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento (Física) , Movimento , Radiometria/métodos , Dosagem Radioterapêutica
12.
Acta Oncol ; 61(9): 1069-1074, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35978529

RESUMO

BACKGROUND: To evaluate the change in parotid glands at mid-treatment during IMRT and the association between radiation dose to the parotid gland stem cell (PGSC) region and patient-reported xerostomia for patients with head and neck cancer (HNC). MATERIAL AND METHODS: Patients who were treated from 2006-2012 at our institution with patient-reported xerostomia outcomes available at least 9 months following RT were included. PG and PGSC regions were delineated and the dose was estimated from the treatment plan dose distribution, using contours from pre- and mid-treatment CT scans. The association between radiation dose and volumetric changes was assessed using linear regression. Univariable logistic regression, logistic dose-response curves, and receiver operating characteristics (ROC) were used to examine the relationship between radiation dose and patient-reported xerostomia. RESULTS: Sixty-three patients were included, most treated with 70 Gy in 33 fractions; 34 patients had mid-treatment CT scans. Both contralateral and ipsilateral PGs had considerable volume reduction from baseline to mid-treatment (25% and 27%, respectively, both p < .001), significantly associated with mean PG dose (-0.44%/Gy, p = .008 and -0.54%/Gy, p < .001, respectively). There was a > 5 Gy difference in mean PG and PGSC dose for 8/34 patients at mid-treatment, with 6/8 (75%) reporting severe xerostomia. Xerostomia prediction based on whole PG or PGSC region dose showed similar performance (ROC AUC 0.754 and 0.749, respectively). The corresponding dose-response models also predicted similar risk of patient-reported xerostomia with mean dose to the contralateral PG (32.5%) or PGSC region (31.4%) at the 20 Gy QUANTEC-recommended sparing level. CONCLUSIONS: The radiation dose to the PGSC region did not show stronger association with patient-reported xerostomia compared to that of whole PG, possibly due to considerable anatomical changes identified at mid-treatment. This shift in the size and position of the PG warrants adaptive planning strategies to evaluate the true benefit of parotid stem cell sparing.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia de Intensidade Modulada , Xerostomia , Humanos , Glândula Parótida/diagnóstico por imagem , Radioterapia de Intensidade Modulada/efeitos adversos , Dosagem Radioterapêutica , Neoplasias de Cabeça e Pescoço/radioterapia , Xerostomia/etiologia , Células-Tronco
13.
Cancer Res ; 82(15): 2678-2691, 2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35919990

RESUMO

Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects. SIGNIFICANCE: Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.


Assuntos
Radioisótopos de Césio , Irradiação Corporal Total , Animais , Raios gama , Camundongos , Raios X
14.
Front Oncol ; 12: 927174, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35903710

RESUMO

Background: Partial breast irradiation with Intra-operative radiotherapy (IORT) has become a popular management option as opposed to whole breast radiation using external beam radiotherapy for breast cancer patients. While previous studies have highlighted the use of IORT in breast cancer patients, there is a scarcity of literature on the use of IORT in those who also have ipsilateral pacemakers. Thus, the aim of our case report is to highlight the applicability of IORT in breast cancer patients who also have a pacemaker. Case Reports: Two female patients with an implanted dual-chamber pacemaker presented with a diagnosis of left-sided invasive ductal carcinoma on mammogram. Mammography of the left breast revealed a 10 mm and 7 mm spiculated mass, respectively, further confirmed with an ultrasound-guided core biopsy that was conclusive of clinical Stage I T1 N0 grade 2, ER +, PR + Her2 - invasive ductal carcinoma. They met our eligibility criteria for IORT, which is being performed as a registry trial. These patients underwent a wide excision lumpectomy along with IORT. Conclusion: Our findings underscore the successful use of targeted IORT for breast-conserving surgery in a patient with invasive ductal carcinoma and pacemaker, hence eliminating the necessity for relocating pacemaker surgeries in these patients. Furthermore, no device failure or malfunction for the pacemaker was recorded before, during, or after the surgery, demonstrating the safety of using IORT in patients with preinstalled pacemaker despite a lack of evidence on safe radiation dosage or manufacturer guidelines. Nonetheless, the effects of IORT on pacemaker < 10 cm were not studied in our patients and further clinical studies are recommended to reinforce the applicability and safe distance of IORT in breast cancer patients with pacemaker.

15.
Int J Radiat Oncol Biol Phys ; 114(3): 529-536, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35787927

RESUMO

PURPOSE: Deep learning-based algorithms have been shown to be able to automatically detect and segment brain metastases (BMs) in magnetic resonance imaging, mostly based on single-institutional data sets. This work aimed to investigate the use of deep convolutional neural networks (DCNN) for BM detection and segmentation on a highly heterogeneous multi-institutional data set. METHODS AND MATERIALS: A total of 407 patients from 98 institutions were randomly split into 326 patients from 78 institutions for training/validation and 81 patients from 20 institutions for unbiased testing. The data set contained T1-weighted gadolinium and T2-weighted fluid-attenuated inversion recovery magnetic resonance imaging acquired on diverse scanners using different pulse sequences and various acquisition parameters. Several variants of 3-dimensional U-Net based DCNN models were trained and tuned using 5-fold cross validation on the training set. Performances of different models were compared based on Dice similarity coefficient for segmentation and sensitivity and false positive rate (FPR) for detection. The best performing model was evaluated on the test set. RESULTS: A DCNN with an input size of 64 × 64 × 64 and an equal number of 128 kernels for all convolutional layers using instance normalization was identified as the best performing model (Dice similarity coefficient 0.73, sensitivity 0.86, and FPR 1.9) in the 5-fold cross validation experiments. The best performing model demonstrated consistent behavior on the test set (Dice similarity coefficient 0.73, sensitivity 0.91, and FPR 1.7) and successfully detected 7 BMs (out of 327) that were missed during manual delineation. For large BMs with diameters greater than 12 mm, the sensitivity and FPR improved to 0.98 and 0.3, respectively. CONCLUSIONS: The DCNN model developed can automatically detect and segment brain metastases with reasonable accuracy, high sensitivity, and low FPR on a multi-institutional data set with nonprespecified and highly variable magnetic resonance imaging sequences. For large BMs, the model achieved clinically relevant results. The model is robust and may be potentially used in real-world situations.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Neoplasias Encefálicas/diagnóstico por imagem , Gadolínio , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos
16.
Med Phys ; 49(8): 5464-5475, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35593052

RESUMO

PURPOSE: Experimental measurements of two-dimensional (2D) dose rate distributions in proton pencil beam scanning (PBS) FLASH radiation therapy (RT) are currently lacking. In this study, we characterize a newly designed 2D strip-segmented ionization chamber array (SICA) with high spatial and temporal resolution and demonstrate its applications in a modern proton PBS delivery system at both conventional and ultrahigh dose rates. METHODS: A dedicated research beamline of the Varian ProBeam system was employed to deliver a 250-MeV proton PBS beam with nozzle currents up to 215 nA. In the research and clinical beamlines, the spatial, temporal, and dosimetric performances of the SICA were characterized and compared with measurements using parallel-plate ion chambers (IBA PPC05 and PTW Advanced Markus chamber), a 2D scintillator camera (IBA Lynx), Gafchromic films (EBT-XD), and a Faraday cup. A novel reconstruction approach was proposed to enable the measurement of 2D dose and dose rate distributions using such a strip-type detector. RESULTS: The SICA demonstrated a position accuracy of 0.12 ± 0.02 mm at a 20-kHz sampling rate (50 µs per event) and a linearity of R2  > 0.99 for both dose and dose rate with nozzle beam currents ranging from 1 to 215 nA. The 2D dose comparison to the film measurement resulted in a gamma passing rate of 99.8% (2 mm/2%). A measurement-based proton PBS 2D FLASH dose rate distribution was compared to simulation results and showed a gamma passing rate of 97.3% (2 mm/2%). CONCLUSIONS: The newly designed SICA demonstrated excellent spatial, temporal, and dosimetric performances and is well suited for commissioning, quality assurance, and a wide range of clinical applications in proton PBS clinical and FLASH-RT.


Assuntos
Terapia com Prótons , Prótons , Imagens de Fantasmas , Terapia com Prótons/métodos , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Síncrotrons
17.
Pract Radiat Oncol ; 12(4): 265-282, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35534352

RESUMO

PURPOSE: This guideline provides updated evidence-based recommendations addressing recent developments in the management of patients with brain metastases, including advanced radiation therapy techniques such as stereotactic radiosurgery (SRS) and hippocampal avoidance whole brain radiation therapy and the emergence of systemic therapies with central nervous system activity. METHODS: The American Society for Radiation Oncology convened a task force to address 4 key questions focused on the radiotherapeutic management of intact and resected brain metastases from nonhematologic solid tumors. The guideline is based on a systematic review provided by the Agency for Healthcare Research and Quality. Recommendations were created using a predefined consensus-building methodology and system for grading evidence quality and recommendation strength. RESULTS: Strong recommendations are made for SRS for patients with limited brain metastases and Eastern Cooperative Oncology Group performance status 0 to 2. Multidisciplinary discussion with neurosurgery is conditionally recommended to consider surgical resection for all tumors causing mass effect and/or that are greater than 4 cm. For patients with symptomatic brain metastases, upfront local therapy is strongly recommended. For patients with asymptomatic brain metastases eligible for central nervous system-active systemic therapy, multidisciplinary and patient-centered decision-making to determine whether local therapy may be safely deferred is conditionally recommended. For patients with resected brain metastases, SRS is strongly recommended to improve local control. For patients with favorable prognosis and brain metastases receiving whole brain radiation therapy, hippocampal avoidance and memantine are strongly recommended. For patients with poor prognosis, early introduction of palliative care for symptom management and caregiver support are strongly recommended. CONCLUSIONS: The task force has proposed recommendations to inform best clinical practices on the use of radiation therapy for brain metastases with strong emphasis on multidisciplinary care.


Assuntos
Neoplasias Encefálicas , Neurocirurgia , Radioterapia (Especialidade) , Radiocirurgia , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Consenso , Humanos , Radiocirurgia/efeitos adversos
18.
J Appl Clin Med Phys ; 23(6): e13609, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35460150

RESUMO

OBJECTIVE: To quantify the clinical performance of a machine learning (ML) algorithm for organ-at-risk (OAR) dose prediction for lung stereotactic body radiation therapy (SBRT) and estimate the treatment planning benefit from having upfront access to these dose predictions. METHODS: ML models were trained using multi-center data consisting of 209 patients previously treated with lung SBRT. Two prescription levels were investigated, 50 Gy in five fractions and 54 Gy in three fractions. Models were generated using a gradient-boosted regression tree algorithm using grid searching with fivefold cross-validation. Twenty patients not included in the training set were used to test OAR dose prediction performance, ten for each prescription. We also performed blinded re-planning based on OAR dose predictions but without access to clinically delivered plans. Differences between predicted and delivered doses were assessed by root-mean square deviation (RMSD), and statistical differences between predicted, delivered, and re-planned doses were evaluated with one-way analysis of variance (ANOVA) tests. RESULTS: ANOVA tests showed no significant differences between predicted, delivered, and replanned OAR doses (all p ≥ 0.36). The RMSD was 2.9, 3.9, 4.3, and 1.7Gy for max dose to the spinal cord, great vessels, heart, and trachea, respectively, for 50 Gy in five fractions. Average improvements of 1.0, 1.4, and 2.0 Gy were seen for spinal cord, esophagus, and trachea max doses in blinded replans compared to clinically delivered plans with 54 Gy in three fractions, and 1.8, 0.7, and 1.5 Gy, respectively, for the esophagus, heart and bronchus max doses with 50 Gy in five fractions. Target coverage was similar with an average PTV V100% of 94.7% for delivered plans compared to 97.3% for blinded re-plans for 50 Gy in five fractions, and respectively 98.4% versus 99.2% for 54 Gy in three fractions. CONCLUSION: This study validated ML-based OAR dose prediction for lung SBRT, showing potential for improved OAR dose sparing and more consistent plan quality using dose predictions for patient-specific planning guidance.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Algoritmos , Humanos , Pulmão , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Aprendizado de Máquina , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
20.
Phys Imaging Radiat Oncol ; 21: 72-77, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35243035

RESUMO

BACKGROUND AND PURPOSE: Disease recurrence and distant metastases (DM) are major concerns for oropharyngeal cancer (OPC) patients receiving definitive chemo-radiotherapy. Here, we investigated whether pre-treatment primary tumor positron emission tomography (PET) features could predict progression-free survival (PFS) or DM. METHODS AND MATERIALS: Primary tumors were delineated on pre-treatment PET scans for patients treated between 2005 and 2018 using gradient-based segmentation. Radiomic image features were extracted, along with SUV metrics. Features with zero variance and strong correlation to tumor volume, stage, p16 status, age or smoking were excluded. A random forest model was used to identify features associated with PFS. Kaplan-Meier methods, Cox regression and logistic regression with receiver operating characteristics (ROC) and 5-fold cross-validated areas-under-the-curve (CV-AUCs) were used. RESULTS: A total of 114 patients were included. With median follow-up 40 months (range: 3-138 months), 14 patients had local recurrence, 21 had DM and 38 died. Two-year actuarial local control, distant control, PFS and overall survival was 89%, 84%, 70% and 84%, respectively. The wavelet_LHL_GLDZM_LILDE feature slightly improved PFS prediction compared to clinical features alone (CV-AUC 0.73 vs. 0.71). Age > 65 years (HR = 2.64 (95%CI: 1.36-5.2), p = 0.004) and p16-negative disease (HR = 3.38 (95%CI: 1.72-6.66), p < 0.001) were associated with poor PFS. A binary radiomic classifier strongly predicted DM with multivariable HR = 3.27 (95%CI: 1.15-9.31), p = 0.027, specifically for patients with p16-negative disease with 2-year DM-free survival 83% for low-risk vs. 38% for high-risk patients (p = 0.004). CONCLUSIONS: A radiomics signature strongly associated with DM risk could provide a tool for improved risk stratification, potentially adding adjuvant immunotherapy for high-risk patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA