RESUMO
Endoscopic endonasal surgery on a 36-year-old man was complicated by perforation of the right internal carotid artery. The immediate, substantial haemorrhage was controlled by packing the sphenoid sinus. Intra-arterial angiography of the right internal carotid artery showed small irregularities proximal to the ophthalmic artery. A follow-up examination two weeks later documented a large pseudoaneurysm in the initially irregular arterial segment, which was successfully treated by endovascular coiling. This case report illustrates the need for angiographic follow-up examinations following traumatic intracranial vessel injury in order to identify late pseudoaneurysm development.
Assuntos
Falso Aneurisma/diagnóstico , Doença Iatrogênica , Procedimentos Cirúrgicos Otorrinolaringológicos/efeitos adversos , Transtornos da Visão/etiologia , Adulto , Falso Aneurisma/etiologia , Seguimentos , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Acuidade VisualRESUMO
Superparamagnetic iron oxide (SPIO) contrast agents, clinically established for high resolution magnetic resonance imaging of reticuloendothelial system containing anatomical structures, can additionally be exploited for the non-invasive characterization and quantification of pathology down to the molecular level. In this context, SPIOs can be applied for non-invasive cell tracking, quantification of tissue perfusion and target specific imaging, as well as for the detection of gene expression. This article provides an overview of new applications for clinically approved iron oxides as well of new, modified SPIO contrast agents for parametric and molecular imaging.
Assuntos
Separação Celular/métodos , Meios de Contraste , Compostos Férricos/metabolismo , Imageamento por Ressonância Magnética/métodos , Técnicas de Sonda MolecularRESUMO
PURPOSE: To investigate the respective diagnostic accuracies of the different breast imaging modalities, i. e., mammography (Mx), high-frequency breast ultrasound (US), and dynamic contrast-enhanced breast (MRI) regarding the early diagnosis of familial (hereditary) breast cancer. MATERIALS AND METHODS: A prospective, non-randomized controlled clinical multi-center trial is performed at 4 academic tertiary care centers in Germany (Ulm, Munchen/Grosshadern, Munster and Bonn) for a total period of 4 years, sponsored by the German Cancer Aid. The protocol consists of semiannual clinical visits and breast ultrasound, and annual bilateral two-view Mx, US and MRI. Imaging studies were first analyzed independently, then Mx was read in conjunction with US, followed by Mx combined with MRI, and finally, all three imaging modalities were read in synopsis. We present the concept and first results of this trial. RESULTS: So far, 748 screening rounds are available for analysis in 613 women. A total of 12 breast cancers have been identified, with 11/12 cases in the pTis or pT1/N0 stage. The mean size of detected invasive cancers was 7 mm. A total of 19 benign lesions were biopsied due to false-positive imaging diagnoses. The breast cancer detection rates were: Mx: 5/12 (42 %), US 3/12 (25 %), MRI 10/12 (83 %), and the positive predictive values: Mx 5/17 (29 %), US 3/15 (30 %), and MRI 10/23 (43 %). CONCLUSION: The preliminary data suggest that early diagnosis of familial breast cancer is feasible by intensified surveillance, in particular with the addition of MRI.
Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética , Mamografia , Ultrassonografia Mamária , Adulto , Biópsia , Mama/patologia , Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Neoplasias da Mama/prevenção & controle , Reações Falso-Positivas , Feminino , Seguimentos , Predisposição Genética para Doença , Alemanha , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Fatores de Risco , Fatores de TempoRESUMO
PURPOSE: To evaluate hygienic conditions using automatic injectors in magnetic resonance imaging (MRI) and computed tomography (CT) during clinical routine. MATERIALS AND METHODS: The surfaces of medical devices (e. g., control console) and the palms of the technical and medical staff were microbiologically analyzed by taking imprints before and after hygienic education. In addition, the injector syringes for contrast medium (CM) and saline were checked for microbiological contamination following multiple (MRI: 14 h; CT 8 h) and single use. Furthermore, the potential of retrograde contamination from the patient along the tube was analyzed. RESULTS: A bacterial contamination with typical dermal bacteria was documented for the surfaces of the medical devices, the palms of the technical and medical staff, and the injection syringes following multiple use (MRI: 10/10 CM syringes, 6/10 saline syringes; CT: 8/10 CM syringes, 5/10 saline syringes). Correct hand disinfection in combination with single use of syringes avoided bacterial colonization. Retrograde bacterial contamination from the patient was not observed. CONCLUSION: Regular hygienic teaching sessions for technical and medical staff in MRI and CT departments using automatic injectors should be mandatory. Furthermore, the multiple use of syringes should be avoided until investigations addressing the potential of bacterial contamination are performed.
Assuntos
Desinfecção , Contaminação de Equipamentos/prevenção & controle , Desinfecção das Mãos , Higiene , Imageamento por Ressonância Magnética/normas , Seringas/microbiologia , Tomografia Computadorizada por Raios X/normas , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/instrumentação , Projetos Piloto , Seringas/normas , Tomografia Computadorizada por Raios X/instrumentaçãoRESUMO
In the industrialized countries, the last 15 years have seen an increasing rate of cases of tuberculosis. However, upper cervical spine tuberculosis involving a cold retropharyngeal abscess is extremely rare. We report on a 58 year old female from Sri Lanka presenting with unspecific neck pain and stiffness. She was diagnosed as having extensive tubercular osteodestruction of the second cervical spine body, including epidural and large retropharyngeal abscesses.
Assuntos
Vértebras Cervicais , Abscesso Retrofaríngeo/diagnóstico , Abscesso Retrofaríngeo/etiologia , Espondilite/diagnóstico , Espondilite/etiologia , Tuberculose da Coluna Vertebral/complicações , Tuberculose da Coluna Vertebral/diagnóstico , Feminino , Humanos , Pessoa de Meia-IdadeRESUMO
To evaluate the sensitivity of T2-weighted fast spin-echo (FSE) sequences to physiological iron depositions in normal brains at MR imaging field strengths of 1.5 and 3.0 T. T2-weighted FSE sequences acquired at 1.5 and 3.0 T clinical imaging systems (Gyroscan Intera, Philips Medical Systems, Best, The Netherlands) were compared by means of MRI in phantoms ( n=6) and healthy volunteers ( n=10). Contrast-to-noise ratios (CNRs) of tubes doped with iron oxides at different concentrations and of brain areas with physiological iron depositions (nucleus ruber, substantia nigra, globus pallidus) were calculated for either field strength. Apparent susceptibility effects of iron-containing brain structures were qualitatively analyzed by comparing the degree of visible hypointensity by a score system at either field strength. The mean CNR of iron oxide tubes and iron-containing brain areas was significantly decreased at 3.0 T. Qualitative analysis confirmed these measurements. Detection and diagnosis of brain disorders with altered iron content such as neurodegenerative parkinsonian disorders (NPD) or intracerebral hemorrhage should benefit from the increased sensitivity of T2-weighted FSE sequences to susceptibility effects at 3.0 T.
Assuntos
Encéfalo/metabolismo , Ferro/metabolismo , Imageamento por Ressonância Magnética , Hemorragia Cerebral , Humanos , Transtornos Parkinsonianos , Imagens de Fantasmas , Sensibilidade e EspecificidadeRESUMO
The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting.
Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/normas , Crânio/patologia , Adulto , Encefalopatias/diagnóstico , Protocolos Clínicos , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Satisfação do PacienteAssuntos
Arteriopatias Oclusivas/diagnóstico , Meios de Contraste , Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Doenças Vasculares Periféricas/diagnóstico , Angiografia Digital , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
PURPOSE: To prospectively determine the value of magnetic resonance imaging (MRI) with flow quantification in the portal vein for the follow-up of patients with transjugular intrahepatic portosystemic shunt (TIPS). METHODS: Thirty-six patients with TIPS (23 m, 13 f) were evaluated with MR of the liver parenchyma and quantification of flow in the portal vein. MR examinations were correlated with Doppler sonography and conventional angiography including measurement of the portal pressure gradient (PPG). In cases of re-interventions (dilatation/stent application) additional examinations with MRI and Doppler sonography were performed. RESULTS: MR flow measurements in the portal vein correlated with Doppler sonography (r = 0.69) whereas no correlation of both methods with the PPG was found. No threshold velocity in the portal vein could be determined to predict shunt stenosis. All shunt occlusions (n = 5) were diagnosed correctly by MRA. Thirty measurements before and after successful angiographic interventions revealed a significant increase in portal flow velocity and a significant decrease of the PPG. Magnetic resonance images enabled a reliable detection of procedural complications (parenchymal bleedings, n = 31; extra and subcaspular hematomas, n = 2 each) and newly occurring hepatocellular carcinomas (n = 2) in the follow-up period. CONCLUSION: Magnetic resonance imaging in the follow-up of TIPS enables a morphological assessment of the liver and an accurate velocity mapping, but is not suited to predict shunt dysfunction as a single method.
Assuntos
Hipertensão Portal/cirurgia , Imageamento por Ressonância Magnética , Veia Porta , Derivação Portossistêmica Transjugular Intra-Hepática , Idoso , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Veia Porta/diagnóstico por imagem , Estudos Prospectivos , Curva ROC , Stents , Ultrassonografia DopplerRESUMO
BACKGROUND: Creatinine is an important clinical laboratory parameter for the evaluation of kidney function. It is essential to determine its concentration in serum of patients suffering from renal insufficiency. During hemodialysis treatment, the measurement of creatinine in the effluent dialysate or ultrafiltrate may give additional information on the efficiency of the extracorporal procedure. Therefore, enzyme sensors with co-immobilized creatinine amidohydrolase, creatine amidinohydrolase and sarcosine oxidase have been used to determine creatinine. METHODS: Enzymatically generated hydrogen peroxide has amperometrically been detected at a platinum-working electrode. To exclude electroactive compounds of the sample matrix, which might interfere with the electrochemical measurement, the sensors have additionally been modified by a Nafion membrane. RESULTS: Such sensors showed a linear detection range of 0.06-1.7 mg/dl for creatinine. Diluting the sample with measuring buffer, it has also been possible to measure pathological creatinine concentrations up to 11 mg/dl. A good correlation between creatinine concentrations in serum, dialysate and ultrafiltrate determined by the presented enzyme sensors and those obtained by both, conventional colorimetric Jaffé and enzymatic measurements have been achieved. CONCLUSION: Further developments will aim at the integration of this measuring principle into the concept to low-cost disposable planar sensors.
Assuntos
Técnicas Biossensoriais , Creatinina/análise , Diálise Renal , Creatina/análise , Soluções para Hemodiálise/análise , Humanos , Reprodutibilidade dos TestesRESUMO
OBJECTIVE: Three-dimensional contrast-enhanced MR angiography was performed to study MR characteristics of Hemobahn devices. MATERIALS AND METHODS: Changes in endoluminal signal intensities and the precision of the endoluminal diameter measurement were investigated in phantom studies for different concentrations of gadopentetate dimeglumine. Before and after the Hemobahn devices had been implanted, 10 patients with peripheral arterial occlusive disease were examined on MR imaging and three-dimensional contrast-enhanced MR angiography. RESULTS: Phantom experiments using three-dimensional MR angiography showed stent-related signal void as a dark ring in the axial image orientation, providing a precise delineation of the stent--vessel border (mean endoluminal diameter, 8.2 mm; SD, 0.6 mm). Changes in endoluminal signal intensity were evaluated quantitatively. Stent-related artifacts did not compromise diagnostic imaging quality. All Hemobahn devices were found to be patent without migration of an implanted graft. In one patient, an extensive perigraft reaction (edema and contrast-enhanced perivascular tissue) was postinterventionally detected on MR imaging and corresponded to clinically evident postimplantation symptoms. CONCLUSION: Three-dimensional contrast-enhanced MR angiography is a suitable tool to follow up the implantation of Hemobahn devices and to detect intra- and extraluminal abnormalities.
Assuntos
Arteriopatias Oclusivas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Stents , Idoso , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagens de FantasmasRESUMO
PURPOSE: To evaluate left ventricular (LV) myocardial function in ten patients with coronary artery disease (CAD) preoperatively and 6 months after coronary bypass grafting (CABG) by cardiac MRI. MATERIAL AND METHODS: Ten patients (mean 65.2 +/- 5.9 years) with angiographically proven CAD and an indication for elective CABG underwent prospective evaluation of global LV function and regional wall motion by Cine-MRI at rest using a multiphase FLASH-2D sequence following regions of interest (ROI)-defined diagnostics of regional myocardial wall motion by means of levocardiography. Within the ROIs a total of 613 LV myocardial segments were analyzed preceding and following surgical revascularization. Results were compared with the data of 10 healthy volunteers. RESULTS: Preoperatively, patients showed reduced stroke volume and ejection fraction compared with volunteers (p < 0.01). Enddiastolic wall thickness (EDWT) and systolic wall thickening (SWT) were significantly lower in the patients (p < 0.01). Based on preoperative levocardiography ROI-defined myocardial segments showed a significantly lower preoperative EDWT in areas with wall motion abnormalities (7.4 +/- 2.5 mm; p < 0.01) than in normal myocardium (9.2 +/- 2.1 mm). Ejection fraction (p < 0.05), endsystolic wall thickness, and SWT (p < 0.01) improved significantly after bypass surgery. On ROI-defined analysis myocardial segments with impaired preoperative wall motion (n = 243) showed a significant increase of EDWT, ESWT and SWT (p < 0.01). CONCLUSION: In patients with CAD, cardiac MRI enables the non-invasive determination of postinfarctional LV remodeling with an increased EDWT of myocardial segments with normal regional wall motion and of the improvement in global and regional myocardial function following coronary bypass surgery.
Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Idoso , Angiografia Coronária , Ponte de Artéria Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Miocárdio Atordoado/diagnóstico , Período Pós-Operatório , Estudos Prospectivos , Volume Sistólico , Fatores de TempoRESUMO
PURPOSE: To evaluate the feasibility and clinical utility of Gd-BOPTA enhanced excretory magnetic resonance urography without additional administration of diuretics in correlation with conventional urography. METHOD: 15 preoperative patients with pelvic tumors were examined at 1.5 T using a breath-hold high-resolution 3D-FLASH sequence during first-pass as well as 5, 10, 15 minutes after i.v. injection of 0.05 mmol/kg BW Gd-BOPTA (MultiHance) without administration of diuretics. Post-processed coronal and multiplanar MIP reconstructions were compared to conventional excretory urography with regard to morphologic accuracy, anatomic variability, filling defects, cause and level of obstruction or compression, tumor visibility, and time-effectiveness by two independent radiologists. RESULTS: Visualization of the urinary tract by MRU was comparable to conventional excretory urography in 14 of 15 cases. Caliceal fornices were better delineated on conventional urographies, whereas MRU was considered superior in the assessment of the inferior ureter sections, the urinary bladder and obstructive tumors, whose extents could be clearly marked out. Examination times of both techniques were comparable. CONCLUSION: These first results show that non-diuretic Gd-BOPTA enhanced MRU is comparable to conventional excretory urography for the preoperative diagnosis of pelvic tumors. Further improvements of this technique seem possible by optimization of examination intervals and injection doses.
Assuntos
Gadolínio , Imageamento por Ressonância Magnética/métodos , Meglumina , Compostos Organometálicos , Neoplasias Pélvicas/diagnóstico , Urografia/métodos , Neoplasias Urológicas/diagnóstico , Adulto , Diuréticos , Humanos , Processamento de Imagem Assistida por Computador , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Variações Dependentes do Observador , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/cirurgia , Reprodutibilidade dos Testes , Neoplasias Ureterais/diagnóstico , Neoplasias Ureterais/diagnóstico por imagem , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias Urológicas/diagnóstico por imagem , Neoplasias Urológicas/cirurgiaRESUMO
PURPOSE: To assess the renal tolerance of 1.0 mol/L gadobutrol as an electrically neutral contrast agent at magnetic resonance (MR) imaging in patients with impaired renal function. MATERIALS AND METHODS: Twenty-one patients with impaired renal function were enrolled in this prospective randomized study and classified into two subgroups according to their creatinine clearance: group 1 (n = 12), less than 80 mL/min (<1.33 mL/sec) and greater than 30 mL/min (>0.50 mL/sec); group 2 (n = 9), less than 30 mL/min (<0.50 mL/sec) and not requiring dialysis. Gadobutrol (1.0 mol/L) was injected intravenously at randomly assigned doses of either 0.1 or 0.3 mmol per kilogram of body weight. Changes in vital signs, clinical chemistry, and urinalysis results, including creatinine clearance, were monitored before, at 6 hours, and then every 24 hours until 72 hours (group 1) or 120 hours (group 2) after intravenous injection of gadobutrol. Hematologic results were checked every other day. RESULTS: No serious adverse event occurred, and no clinically relevant changes in vital signs, hematologic results, clinical chemistry, or urinalysis results were detected in the observation period. Markers for glomerular filtration (creatinine, cystatin C, beta2-microglobulin, creatinine clearance) and tubular function (N-acetyl-beta-D-glucosaminidase, alpha1-microglobulin) were unaffected by gadobutrol in both groups. CONCLUSION: Gadobutrol did not affect renal function and, therefore, proved to be a safe MR contrast agent in patients with impaired renal function. Even in patients with marginal excretory function (creatinine clearance, <30 mL/min [<0.50 mL/sec]), prehydration or treatment with diuretics or hemodialysis are not required after the administration of gadobutrol.
Assuntos
Meios de Contraste/toxicidade , Falência Renal Crônica/fisiopatologia , Rim/efeitos dos fármacos , Compostos Organometálicos/toxicidade , Adulto , Idoso , Meios de Contraste/administração & dosagem , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Estudos ProspectivosRESUMO
PURPOSE: To evaluate the influence of different membrane materials on the efficiency of iopromide elimination. MATERIAL AND METHODS: Twenty stable patients with chronic renal failure after coronary angiography were investigated for contrast medium elimination during hemodialysis directly after contrast medium application. RESULTS: Clearance during hemodialysis with cuprophan membranes was 102 +/- 7 mg/ml in contrast to 153 +/- 4 mg/ml in polysulfone membranes. Elimination half-time was 94 +/- 5 min in cuprophan and 79 +/- 3 min in polysulfone membranes, and the elimination rate after 120 min was 59 +/- 2% and 66 +/- 1.5% respectively. Plasma clearance of iopromide was elevated in polysulfone membranes (188 +/-17 ml/min); however, not significantly different to cuprophane membranes (153 +/-11 ml/min). Accordingly, 24-h urinary iopromide excretion was reduced to 26 +/- 4 g/24 h vs. 32 +/- 7 g/24 h. CONCLUSION: Hemodialysis for iopromide elimination with polysulfone membranes is more effective than with cuprophan membranes.
Assuntos
Celulose/análogos & derivados , Meios de Contraste/farmacocinética , Iohexol/análogos & derivados , Iohexol/farmacocinética , Membranas Artificiais , Diálise Renal , Humanos , Falência Renal Crônica/metabolismo , Falência Renal Crônica/terapia , Polímeros , SulfonasRESUMO
Haemodialysis for the elimination of contrast medium in patients with advanced renal failure is a common procedure. Even though sufficient elimination with the use of regular low-flux membranes is documented, large differences in results have been reported in prior investigations. We, therefore, compared Cuprophan and polysulfone dialysers with different surface areas to haemofiltration with different amounts of substitution fluid in 40 patients with compromised renal function after coronary angiography. Plasma iodine concentrations were measured by fluorescent excitation analysis. At constant blood flow rates of 200 ml/min, Cuprophan membranes with 1. 3 m(2) surface area had a clearance rate of 87 ml/min, whereas polysulfone membranes of comparable size displayed a significantly higher clearance rate of 147 ml/min. Polysulfone membranes with 1.8 m(2) surface area showed a small but insignificant increase in the iodine clearance (162 ml/min), while Cuprophan membranes displayed an increase in clearance rates (121 ml/min). Additional ultrafiltration led to a further increase in the plasma clearance of both membranes and reduced urinary iodine excretion. Haemofiltration was comparable to haemodialysis in terms of efficacy and thus represents an alternative method. Clearance of iopromide during haemodialysis with polysulfone membranes is higher than with Cuprophan membranes. Elimination rates can be further increased by additional ultrafiltration. Haemofiltration is comparable to haemodialysis regarding contrast medium elimination.
Assuntos
Materiais Biocompatíveis , Celulose/análogos & derivados , Meios de Contraste/farmacocinética , Iohexol/análogos & derivados , Iohexol/farmacocinética , Rim/fisiopatologia , Membranas Artificiais , Polímeros , Diálise Renal/instrumentação , Diálise Renal/métodos , Sulfonas , Angiografia Coronária , Taxa de Filtração Glomerular , Humanos , Iodo/sangue , Propriedades de Superfície , Fatores de TempoRESUMO
The objective of this study was to compare the diagnostic performance of a dedicated orthopedic magnetic resonance (MR) imaging system (0.18 T) and a conventional MR imaging system (1.0 T) in the detection of articular cartilage lesions. Fifty knee joint specimens of pigs with artificially created articular cartilage lesions of different diameters, grades (2-3), and localizations, as well as 50 joints with intact articular cartilage, were imaged at 0. 18 and 1.0 T. Diagnostic performance was determined by means of receiver operating characteristics (ROC) analysis with three independent observers. For none of the pulse sequences used at 0.18 T or 1.0 T areas under ROC curves (A(z)) showed significant differences between the three observers. A(z) values from averaged data were as follows: a) 0.18 T: T1-weighted spin echo (SE): 0.70, proton-density-weighted SE: 0.59, T2-weighted SE: 0.61, two-dimensional (2D) gradient-echo (GRE): 0.73, 3D GRE: 0.75; and b) 1.0 T: T1-weighted SE: 0.73, fat-suppressed T2-weighted turbo-SE: 0. 79, 2D fast low-angle shot (FLASH): 0.79, fat-suppressed 3D FLASH: 0. 96, and water-excited 3D double-echo steady state (DESS): 0.96. With the use of 3D pulse sequences, the high-field system demonstrated a significantly better diagnostic performance than the low-field system in the detection of grades 2 and 3 articular cartilage lesions (P < 0.001).
Assuntos
Cartilagem Articular/patologia , Aumento da Imagem/métodos , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Animais , Feminino , Técnicas In Vitro , Masculino , Curva ROC , Distribuição Aleatória , Sensibilidade e Especificidade , SuínosRESUMO
RATIONALE AND OBJECTIVES: To investigate the pharmacokinetics of 1M gadobutrol as a new neutral MR contrast agent in patients with impaired renal function. METHODS: Twenty-one patients with impaired renal function and any indication for a contrast-enhanced MRI were enrolled into this prospective study and classified in two subgroups according to their creatinine clearance (group 1, 30-80 mL/ min; group 2, 30 mL/min or less, not requiring dialysis). Eleven patients were assigned to the lower dose of 0.1 mmol Gd/kg and 10 patients to the higher dose of 0.3 mmol Gd/kg. To calculate pharmacokinetic parameters, urine and venous blood samples were drawn at baseline and up to 72 hours for group 1 and 120 hours for group 2 after administration of gadobutrol. RESULTS: The predominant extracellular distribution of gadobutrol at steady state did not change according to the degree of renal impairment. The mean elimination half-life of gadobutrol increased to 7.4 +/- 2.6 hours (0.1 mmol/kg) and 5.4 +/- 1.5 hour (0.3 mmol/kg) in group 1 and to 17.9 +/- 6.2 hours (0.1 mmol/kg) and 20.4 +/- 16.9 hours (0.3 mmol/kg) in group 2, compared with 1.5 hours in healthy volunteers. The relation between serum (tbeta) and urine (t(elim)) elimination half-lives, as well as total serum and renal clearance, indicated renal elimination as the main pathway of elimination. The recovery of gadobutrol in the urine of group 1 was complete within 72 hours for both dosage levels. Patients with severe renal impairment showed a mean recovery of 80.1% (0.1 mmol/kg) and 85.3% (0.3 mmol/kg) within the observation period of 120 hours. CONCLUSIONS: The half-life of gadobutrol is prolonged in patients with impaired renal function, but elimination by means of the kidneys is the predominant route.