RESUMO
We previously reported short-term outcomes for stenting of aortic coarctation (CoA) (native or re-coarctation) with newer generation low-profile stents (Valeo, Formula, and Begraft stents) in children under 30 kg. We present here the medium-term outcomes of this procedure. Retrospective review of patients weighing under 30 kg who had percutaneous stent treatments for coarctation between 2012 and 2021 was performed. Clinical and procedural data were collected; 19 patients were included. The median age at the time of procedure was 5.1 [4.1-6.4] years and median weight 21.0 [17.3-22.3] kg. One patient had a history of re-coarctation. Thirteen (68%) patients were on anti-hypertensives pre-procedure. Different types of stents were used (14 Valeo™, 4 Formula® 535, 1 BeGraft), which can all be dilated to 18 mm or larger. One patient required a 9 F sheath, all others required a 7 F sheath. The narrowest diameter in the aorta increased from a median of 3.5 [3.0-4.5] to 9.4 [8.9-9.8] mm, p < 0.001; there was a reduction in the median pressure gradient across the coarctation from 35.0 [30.0-43.0] to 5.0 [0-10.0] mmHg, p < 0.001. There were no intra-procedural complications. Follow-up was for a median of 56.0 [13.0-65.0] months. Five (26%) of patients underwent re-intervention after a median time frame of 40.0 [39.5-52.0] months; four had balloon dilation, one had repeat stent implantation. Five (26%) patients were on anti-hypertensive agent(s) post-intervention. Our single centre experience demonstrates that percutaneous stenting for coarctation of aorta in children under 30 kg, with low-profile stents, had no significant complications during the median follow-up time of 56 months. This study demonstrated that the procedure is safe and effective for short and medium-term therapy in this group of patients with a 26% re-intervention rate. A quarter of patients remained on anti-hypertensive medication post stenting, emphasizing the importance of long-term follow-up.
Assuntos
Coartação Aórtica , Criança , Humanos , Seguimentos , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Resultado do Tratamento , Stents/efeitos adversos , Aorta , Anti-Hipertensivos , Estudos RetrospectivosRESUMO
BACKGROUND: COVID-19 has caused significant worldwide morbidity and mortality. Congenital heart disease (CHD) is likely to increase vulnerability and understanding the predictors of adverse outcomes is key to optimising care. OBJECTIVE: Ascertain the impact of COVID-19 on people with CHD and define risk factors for adverse outcomes. METHODS: Multicentre UK study undertaken 1 March 2020-30 June 2021 during the COVID-19 pandemic. Data were collected on CHD diagnoses, clinical presentation and outcomes. Multivariable logistic regression with multiple imputation was performed to explore predictors of death and hospitalisation. RESULTS: There were 405 reported cases (127 paediatric/278 adult). In children (age <16 years), there were 5 (3.9%) deaths. Adjusted ORs (AORs) for hospitalisation in children were significantly lower with each ascending year of age (OR 0.85, 95% CI 0.75 to 0.96 (p<0.01)). In adults, there were 24 (8.6%) deaths (19 with comorbidities) and 74 (26.6%) hospital admissions. AORs for death in adults were significantly increased with each year of age (OR 1.05, 95% CI 1.01 to 1.10 (p<0.01)) and with pulmonary arterial hypertension (PAH; OR 5.99, 95% CI 1.34 to 26.91 (p=0.02)). AORs for hospitalisation in adults were significantly higher with each additional year of age (OR 1.03, 95% CI 1.00 to 1.05 (p=0.04)), additional comorbidities (OR 3.23, 95% CI 1.31 to 7.97 (p=0.01)) and genetic disease (OR 2.87, 95% CI 1.04 to 7.94 (p=0.04)). CONCLUSIONS: Children were at low risk of death and hospitalisation secondary to COVID-19 even with severe CHD, but hospital admission rates were higher in younger children, independent of comorbidity. In adults, higher likelihood of death was associated with increasing age and PAH, and of hospitalisation with age, comorbidities and genetic disease. An individualised approach, based on age and comorbidities, should be taken to COVID-19 management in patients with CHD.
Assuntos
COVID-19 , Cardiopatias Congênitas , Hipertensão Arterial Pulmonar , Adulto , Humanos , Criança , Adolescente , COVID-19/terapia , COVID-19/complicações , Pandemias , Hospitalização , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/terapia , Hipertensão Pulmonar Primária FamiliarRESUMO
Paediatric inflammatory multisystem syndrome temporally associated with COVID-19 (PIMS-TS) is a novel condition that was first reported in April, 2020. We aimed to develop a national consensus management pathway for the UK to provide guidance for clinicians caring for children with PIMS-TS. A three-phase online Delphi process and virtual consensus meeting sought consensus over the investigation, management, and research priorities from multidisciplinary clinicians caring for children with PIMS-TS. We used 140 consensus statements to derive a consensus management pathway that describes the initial investigation of children with suspected PIMS-TS, including blood markers to help determine the severity of disease, an echocardiogram, and a viral and septic screen to exclude other infectious causes of illness. The importance of a multidisciplinary team in decision making for children with PIMS-TS is highlighted throughout the guidance, along with the recommended treatment options, including supportive care, intravenous immunoglobulin, methylprednisolone, and biological therapies. These include IL-1 antagonists (eg, anakinra), IL-6 receptor blockers (eg, tocilizumab), and anti-TNF agents (eg, infliximab) for children with Kawasaki disease-like phenotype and non-specific presentations. Use of a rapid online Delphi process has made it possible to generate a national consensus pathway in a timely and cost-efficient manner in the middle of a global pandemic. The consensus statements represent the views of UK clinicians and are applicable to children in the UK suspected of having PIMS-TS. Future evidence will inform updates to this guidance, which in the interim provides a solid framework to support clinicians caring for children with PIMS-TS. This process has directly informed new PIMS-TS specific treatment groups as part of the adaptive UK RECOVERY trial protocol, which is the first formal randomised controlled trial of therapies for PIMS-TS globally.
Assuntos
COVID-19/epidemiologia , Procedimentos Clínicos/normas , Gerenciamento Clínico , Síndrome de Resposta Inflamatória Sistêmica , COVID-19/imunologia , COVID-19/terapia , Criança , Consenso , Humanos , Comunicação Interdisciplinar , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Síndrome de Resposta Inflamatória Sistêmica/imunologia , Síndrome de Resposta Inflamatória Sistêmica/terapia , Reino UnidoRESUMO
To report our experience of coarctation stent therapy in small children weighing less than 30 kg, with the low profile dilatable Valeo stent and review the literature on coarctation stent therapy in this patient population. Coarctation stent implantation was undertaken in 14 consecutive children using the Bard Valeo Stent. Demographic, angiographic, echocardiographic and clinical data were reviewed retrospectively. The median age at the time of procedure was 5.1 (2.6-7.5) years and median weight was 20.8 (14.7-27) kg. There was improvement in median coarctation diameter from 4 (1.3-5.2) to 9.5 (5.8-12.7) mm, p < 0.001; and a reduction in the median peak pressure gradient across the coarctation from 35 (20-49) to 9 (0-15) mmHg, p < 0.001. Median stent recoil was 7.9 (0-20)%. There was one case of access related complication that resolved without sequelae. Follow-up was a median of 15 (3.0-57.2) months. CT angiogram performed at a median time of 3.3 (2.6-10.2) months post procedure showed no aortic wall injury and preserved stent integrity in all cases. Two children underwent re-intervention for stent dilation and further stent implantation due to in-stent stenosis and somatic growth after 3 years. Six of fourteen children remained on a single antihypertensive agent post-intervention at last follow-up. Implantation of the dilatable Valeo stent is a feasible treatment strategy in native or recurrent coarctation in small children, accepting that additional stent implantation may be necessary with somatic growth. Further study is required to determine longer-term stent efficacy and clinical outcome.
Assuntos
Aorta/cirurgia , Coartação Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Stents/efeitos adversos , Angiografia/métodos , Anti-Hipertensivos/administração & dosagem , Aorta/fisiopatologia , Coartação Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do TratamentoRESUMO
OBJECTIVES: This study aimed to report our national experience with transcatheter patent ductus arteriosus (PDA) occlusion in infants weighing <6 kg. BACKGROUND: The technique of transcatheter PDA closure has evolved in the past two decades and is increasingly used in smaller patients but data on safety and efficacy are limited. METHODS: Patients weighing < 6 kg in whom transcatheter PDA occlusion was attempted in 13 tertiary paediatric cardiology units in the United Kingdom and Ireland were retrospectively analyzed to review the outcome and complications. RESULTS: A total of 408 patients underwent attempted transcatheter PDA closure between January 2004 and December 2014. The mean weight at catheterization was 4.9 ± 1.0 kg and mean age was 5.7 ± 3.0 months. Successful device implantation was achieved in 374 (92%) patients without major complication and of these, complete occlusion was achieved in 356 (95%) patients at last available follow-up. Device embolization occurred in 20 cases (5%). The incidence of device related obstruction to the left pulmonary artery or aorta and access related peripheral vascular injury were low. There were no deaths related to the procedure. CONCLUSIONS: Transcatheter closure of PDA can be accomplished in selected infants weighing <6 kg despite the manufacturer's recommended weight limit of 6 kg for most ductal occluders. The embolization rate is higher than previously reported in larger patients. Retrievability of the occluder and duct morphology needs careful consideration before deciding whether surgical ligation or transcatheter therapy is the better treatment option.
Assuntos
Peso Corporal , Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/terapia , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Tomada de Decisão Clínica , Permeabilidade do Canal Arterial/diagnóstico por imagem , Humanos , Lactente , Irlanda , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Reino UnidoAssuntos
Síndrome de Loeys-Dietz/diagnóstico , Fenótipo , Idoso , Feminino , Humanos , Síndrome de Loeys-Dietz/genética , Masculino , Pessoa de Meia-Idade , Mutação , Linhagem , Proteínas Serina-Treonina Quinases/genética , Receptor do Fator de Crescimento Transformador beta Tipo II , Receptores de Fatores de Crescimento Transformadores beta/genéticaRESUMO
BACKGROUND: There are several options available for aortic valve replacement (AVR), with few comparative reports in the literature. The optimal choice for AVR in each age group is not clear. OBJECTIVES: The study sought to report and compare outcomes after AVR in the young using data from a national database. METHODS: AVR procedures were compared after advanced matching, both in pairs and in a 3-way manner, using a Bayesian dynamic survival model. RESULTS: A total of 1,501 patients who underwent AVR in the United Kingdom between 2000 and 2012 were included. Of these, 47.8% had a Ross procedure, 37.8% a mechanical AVR, 10.9% a bioprosthesis AVR, and 3.5% a homograft AVR, with Ross patients being significantly younger when compared to the other groups. Overall survival at 12 years was 94.6%. In children, the Ross procedure had a 12.7% higher event-free probability (death or any reintervention) at 10 years when compared to mechanical AVR (p = 0.05). We also compared all procedures except the homograft in a matched population of young adults, where the bioprosthesis had the lowest event-free probability of 78.8%, followed by comparable results in mechanical AVR and Ross, with 86.3% and 89.6%, respectively. Younger age was associated with mortality and pulmonary reintervention in the Ross group and with aortic reintervention in the mechanical AVR. Of all 3 options, only the patients undergoing the Ross procedure approached the survival of the general population. CONCLUSIONS: AVR in the young achieves good results, with the Ross being overall better suited for this age group, especially in children. Although freedom from aortic valve reintervention is superior after the Ross procedure, the need for homograft reinterventions is an issue to take into account. All methods have advantages and limitations, with reinterventions being an issue in the long term for all, more crucially in smaller children.
Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Adolescente , Adulto , Fatores Etários , Bioprótese , Criança , Pré-Escolar , Feminino , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Humanos , Lactente , Recém-Nascido , Masculino , Modelos Estatísticos , Reoperação/estatística & dados numéricos , Reino Unido/epidemiologia , Adulto JovemRESUMO
OBJECTIVE: To describe the longer-term clinical experience and follow-up with perventricular device closure of ventricular septal defects (VSD) in children. METHODS: Between January 2005 and December 2013, muscular ventricular septal defect closure with the Amplatzer Muscular VSD Occluder was undertaken using a hybrid perventricular approach. Data including demographic, echocardiographic parameter, and clinical outcome were reviewed retrospectively. RESULTS: Median age at the time of procedure was 8.9 months (range 1.9-31.0 months) and median weight was 6.6 kg (range 4.5-12.9 kg). All had a moderate to large muscular VSD, three had more than one VSD, four had previous coarctation repair, and five had previous pulmonary artery (PA) banding. A single Amplatzer muscular occluder (range 8-18 mm) was deployed in each patient without cardiopulmonary bypass under echocardiographic guidance. Two of ten patients subsequently required a short period of cardiopulmonary bypass for reconstruction of PA after de-banding and closure of atrial septal defect in one. Occluder removal was necessary in one patient due to entrapment of the tricuspid valve and progressive tricuspid regurgitation. This patient underwent surgical repair with a good result and no device-related valve damage. In the remaining nine patients, no severe complications such as device embolization, arrhythmia, or significant valve regurgitation were noted in the post-operative period or follow-up. At a median time of 6.5 years (range 0.9-8.4 years) post device implantation, complete closure was achieved in five patients and four had small residual leaks, which were not hemodynamically significant. CONCLUSION: Perventricular muscular VSD closure is effective in small children with suitable muscular defects and may avoid the morbidity associated with cardiopulmonary bypass and conventional surgical repair. There have been no late complications with this approach.
Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Ponte Cardiopulmonar/métodos , Pré-Escolar , Estudos de Coortes , Terapia Combinada , Bases de Dados Factuais , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Lactente , Masculino , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Medição de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: To describe the long-term clinical experience and follow-up with the Amplatzer Ductal Occluder II (ADO II) in children. METHODS: All patients undergoing attempted transcatheter closure of patent arterial duct (PDA) with the ADO II were included. Data collected included demographic, clinical, and echocardiographic parameters. RESULTS: From March 2008 until March 2013, 62 patients with a median age of 1.2 years (range 0.43-11.1 years) and median weight of 9 kg (range 4.7-31.4 kg) underwent the procedure. The median measurement for minimal ductal diameter was 2.7 mm (range 1.3-5 mm). An ADO II was implanted in 60 patients (96.8%). Two patients had significant residual shunting following deployment of the ADO II and underwent closure with the Amplatzer ductal occluder I (ADO I) during the same procedure. In six patients, the initial ADO II was unsatisfactory, and after recapture a different size ADO II was deployed. Device embolization of the ADO II to the pulmonary artery occurred in 6.7% of patients. Of these, one underwent surgical closure and three were closed with an ADO I. Complete occlusion on echocardiography was noted prior to discharge in 87.5% of the deployed occluders and 100% at first follow-up. Five year follow-up (n = 25) revealed a 100% occlusion rate. There were three cases of persistent mild left pulmonary artery stenosis at long-term follow-up. CONCLUSIONS: The ADO II is effective for occlusion of PDA with variable anatomy from either arterial or venous approaches with a low profile delivery system. Stable occluder position is highly dependent on accurate device sizing, good quality imaging to visualize device configuration after deployment and operator experience.
Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Permeabilidade do Canal Arterial/cirurgia , Dispositivo para Oclusão Septal , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Ecocardiografia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: To describe early clinical experience with the amplatzer ductal occluder II additional sizes (ADO II AS) for percutaneous arterial duct occlusion in infants and small children. METHODS: Pre-, intra- and postprocedural data analysis of all patients undergoing arterial duct occlusion with the ADO II AS from three tertiary referral centers. RESULTS: 17 patients (10 female) with a median age of 6 months (range 1.0-48.1 months) and a median weight of 5.7 kg (range 1.7-17.4 kg) underwent attempted transcatheter ductal closure with the ADO II AS. Retrograde arterial approach was used in eight patients with transvenous femoral approach used in nine. The mean minimal ductal diameter was 2.2 ± 0.7 mm with mean ductal length of 6.8 ± 1.7 mm. Device sizes used were 5/6 (n = 5), 3/4 (n = 4), 4/4 (n = 3), 4/6 (n = 3), and 5/4 (n = 2) with four French delivery sheaths used in all cases. The median fluoroscopy time was 5.7 ± 1.8 min. Two patients underwent delivery under exclusive echocardiography guidance. Complete ductal occlusion was achieved by the end of the procedure in 13 patients. Device embolization to the left pulmonary artery occurred in one patient with successful surgical removal and ligation of the arterial duct. Three patients required device resizing following deployment of the initial device. Complete ductal occlusion without aortic arch or left pulmonary artery stenosis has been identified in all 16 remaining patients on transthoracic echocardiographic follow-up at median of 4.2 months. CONCLUSIONS: The new amplatzer ductal occluder II AS achieves excellent ductal closure rates through low profile delivery systems in small infants and children with variable ductal anatomy. © 2012 Wiley Periodicals, Inc. © 147.
RESUMO
OBJECTIVES: To describe early clinical experience with the amplatzer ductal occluder II additional sizes (ADO II AS) for percutaneous arterial duct occlusion in infants and small children. METHODS: Pre-, intra- and postprocedural data analysis of all patients undergoing arterial duct occlusion with the ADO II AS from three tertiary referral centers. RESULTS: 17 patients (10 female) with a median age of 6 months (range 1.0-48.1 months) and a median weight of 5.7 kg (range 1.7-17.4 kg) underwent attempted transcatheter ductal closure with the ADO II AS. Retrograde arterial approach was used in eight patients with transvenous femoral approach used in nine. The mean minimal ductal diameter was 2.2 ± 0.7 mm with mean ductal length of 6.8 ± 1.7 mm. Device sizes used were 5/6 (n = 5), 3/4 (n = 4), 4/4 (n = 3), 4/6 (n = 3), and 5/4 (n = 2) with four French delivery sheaths used in all cases. The median fluoroscopy time was 5.7 ± 1.8 min. Two patients underwent delivery under exclusive echocardiography guidance. Complete ductal occlusion was achieved by the end of the procedure in 13 patients. Device embolization to the left pulmonary artery occurred in one patient with successful surgical removal and ligation of the arterial duct. Three patients required device resizing following deployment of the initial device. Complete ductal occlusion without aortic arch or left pulmonary artery stenosis has been identified in all 16 remaining patients on transthoracic echocardiographic follow-up at median of 4.2 months. CONCLUSIONS: The new amplatzer ductal occluder II AS achieves excellent ductal closure rates through low profile delivery systems in small infants and children with variable ductal anatomy.
Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Fatores Etários , Ligas , Cateterismo Cardíaco/efeitos adversos , Pré-Escolar , Remoção de Dispositivo , Permeabilidade do Canal Arterial/diagnóstico , Inglaterra , Feminino , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Humanos , Lactente , Irlanda , Ligadura , Masculino , Desenho de Prótese , Artéria Pulmonar/cirurgia , Radiografia Intervencionista , Estudos Retrospectivos , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de IntervençãoRESUMO
The presence of an atrial septal defect in pulmonary hypertension has benefits and detractions. Even in idiopathic pulmonary arterial hypertension, a significant left-to-right shunt at atrial level may increase the pulmonary arterial pressure and exacerbate the disease. However, it is well recognised that the presence of an atrial communication may be protective in subgroups with severe disease, allowing maintenance of cardiac output during times of increased pulmonary resistance. In the present paper, we present the case of a young boy with significant idiopathic pulmonary arterial hypertension and an atrial septal defect. We report our technique of septal occlusion using a device to decrease left-to-right shunting with concomitant stent insertion in that device to maintain the potential for right-to-left shunting during times of high pulmonary arterial pressure.
Assuntos
Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Hipertensão Pulmonar/cirurgia , Dispositivo para Oclusão Septal , Stents , Cateterismo Cardíaco/instrumentação , Criança , Hipertensão Pulmonar Primária Familiar , Comunicação Interatrial/complicações , Humanos , Hipertensão Pulmonar/complicações , Masculino , Resultado do TratamentoRESUMO
BACKGROUND: Stenting for aortic coarctation is known to be effective in the medium term. Aneurysm formation following stent implantation is a recognised complication. However, data regarding aortic wall injury and stent integrity following stent placement are sparse. OBJECTIVES: We report comprehensive clinical, echocardiographic and prospective CT follow-up data following stenting for aortic coarctation from a single centre. Methods Full data analysis of all patients undergoing balloon expandable stent implantation and follow-up procedures in a single tertiary congenital cardiac unit. RESULTS: Between October 2002 and April 2008, we performed 102 coarctation stent procedures on 88 patients. Median age was 20.6 years (range 8.5-65) and median weight 65 kg (range 34-101). 94 stents (26 covered) were implanted. 12 procedures were re-dilatations. Stenting resulted in a reduction of the gradient across the site of coarctation, from a median of 20 mm Hg to 4 mm Hg. There were no procedure-related deaths. Four patients had immediate complications (one requiring emergency surgery). During median follow-up of 34.5 months (range 4.2-72.8), two patients had late complications requiring additional stent procedures. Follow-up CT data are available in 84 patients with MRI in one patient (96.5%). Only one patient developed a procedure-related aortic aneurysm. All stent fractures (n=7) occurred with a single stent design. CONCLUSIONS: Stenting for aortic coarctation and re-coarctation is effective with low immediate complication rates. CT is useful in the longer term for assessment of stent integrity and post-procedural aneurysm formation. Overall incidence of post-procedural aneurysm is rare and stent fractures were not seen with newer generation stents.
Assuntos
Aneurisma Aórtico/etiologia , Coartação Aórtica/terapia , Cateterismo/métodos , Stents , Doença Aguda , Adolescente , Adulto , Idoso , Aorta/lesões , Aneurisma Aórtico/diagnóstico por imagem , Cateterismo/efeitos adversos , Criança , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Stents/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto JovemRESUMO
OBJECTIVES: To describe the early single-center clinical experience with the Amplatzer Ductal Occluder II (ADO II). METHODS: All patients undergoing attempted transcatheter closure of persistent arterial duct (PDA) with the ADO II were included. Data collected included demographic, clinical, and echocardiographic parameters. RESULTS: From March until September 2008, 29 procedures were undertaken in 27 patients (21 female). Median age was 1.4 years (range 0.4-76 years) with median weight 9.4 kg (range 4.7-108 kg). A transarterial approach was used in 2 patients. The median minimum ductal diameter was 2.7 mm (range 1.7-5). ADO II was released in 25 patients (92.5%). Two patients had significant residual shunting following deployment of ADO II and underwent closure with Amplatzer ductal occluder (ADO I). Postprocedural echocardiography identified one occluder had changed position with development of a significant leak and one occluder had embolized to the left pulmonary artery. Both occluders were retrieved successfully at a second catheter procedure. Complete occlusion was noted predischarge in 22 of the remaining 23 occluders (96%). One patient had mild flow acceleration in the left pulmonary artery which has resolved. CONCLUSIONS: The ADO II is highly effective at providing rapid occlusion of morphologically varied PDAs. Occluder design allows closure with arterial or venous approach and delivery with 4 or 5 F delivery catheters. Stable occluder position is dependent on correct positioning of both aortic and pulmonary discs. A larger range of sizes and configurations of this occluder may be required to successfully occlude all ductal sizes and morphologies.
Assuntos
Oclusão com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Adulto , Idoso , Oclusão com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Hemodinâmica , Humanos , Lactente , Masculino , Seleção de Pacientes , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Resultado do Tratamento , UltrassonografiaRESUMO
OBJECTIVES: To describe the evolution of transcatheter closure of perimembranous ventricular septal defects (PMVSD) using either the Amplatzer membranous or muscular occluders in a single centre. METHODS: Retrospective analysis of all patients referred for transcatheter PMVSD closure from December 2003 to December 2007. All patients met unit criteria for surgical closure. RESULTS: There were 27 procedures on 25 patients (11 male) with a preprocedure diagnosis of a PMVSD. Median age was 9.6 years (1.8-32.8). Median weight was 28 kg (10.2-86). Defect size on TOE ranged from 5 to 12 mm. Median Qp:Qs was 1.6:1. A muscular occluder was used in six patients. Median procedure time was 93.5 min (51-214). Implantation was ultimately successful in 23 patients (92%). Acute aortic incompetence resulting in occluder removal occurred in two cases, one requiring surgical removal. Another patient had an aborted attempt but had subsequent successful closure in another unit. Median follow-up is 19.5 months (1-42). Five patients (22%) have trivial/mild residual leak across the occluder at their latest assessment, the majority of which had an aneurysmal perimembranous septum (n = 4). Two patients (8%) developed new trivial to mild aortic incompetence. To date, none of the patients in our group have developed complete heart block. CONCLUSIONS: Transcatheter closure of PMVSD is evolving and should be considered an acceptable alternative to surgery in selected subgroups. Avoidance of oversized occluders and use of muscular occluders in those with aneurysmal defects may help to avoid heart block and aortic regurgitation. Muscular occluders may however interfere with tricuspid valve function.
Assuntos
Cateterismo Cardíaco , Comunicação Interventricular/terapia , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Remoção de Dispositivo , Desenho de Equipamento , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto JovemRESUMO
Despite the wide variety of occlusion devices available for closing the patent ductus arteriosus; some defects with unusual morphology still remain a challenge. The drive for increasingly user friendly and lower caliber delivery systems is also ongoing. The new amplatzer ductal occluder II may prove to be a useful additional tool in these circumstances. We describe our initial experiences with this new device in three patients with long tubular (Type C) ducts.
Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Desenho de Equipamento , Humanos , Lactente , Radiografia Intervencionista , Resultado do TratamentoRESUMO
OBJECTIVES: We describe our complete experience with covered stent implantation for aortic coarctation including short- to medium-term outcomes. BACKGROUND: Coarctation of the aorta is a heterogeneous disease process with multiple associated complications both with and without treatment. Covered stents have evolved to provide greater support to the aortic wall and a varied approach with choice of stent tailored to the anatomy of the patient is required. METHODS: We retrospectively analyzed consecutive patient data from two congenital heart centers from March 2003 to October 2007. RESULTS: We implanted 38 covered stents in 37 patients (20 female) of which three were self-expanding stents. Median age was 29.6 years (9-65) with median weight of 71.5 kg (35-95). The indications for stent placement were native coarctation (n = 13); recurrent coarctation following surgical treatment (n = 11); aneurysm associated with previous coarctation surgery (n = 7); aorto-bronchial fistula leading to acute hemoptysis (n = 2); stent fracture (n = 1); associated arterial duct (n = 2). One patient had a combination of acquired coarctation and false aneurysm. The median screening time was 10 min (3-22). The median systolic gradient of 26 mm Hg (10-60) was reduced to 4 mm Hg (0-20) postprocedure (P < 0.001). There were no deaths on median follow up of 11.5 months (1-56). One patient developed aortic rupture during the procedure and required emergency surgery. CONCLUSION: Covered stent implantation for treatment of aortic coarctation is safe and highly effective in selected patients. Self-expanding stent grafts may be preferable to balloon expandable stents when there is aneurysm formation in the setting of aortopathy.
Assuntos
Angioplastia Coronária com Balão , Aneurisma Aórtico/complicações , Coartação Aórtica/complicações , Coartação Aórtica/terapia , Materiais Revestidos Biocompatíveis , Stents , Adolescente , Adulto , Idoso , Aneurisma Aórtico/terapia , Criança , Estudos de Coortes , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Poliésteres , Politetrafluoretileno , Estudos Retrospectivos , Resultado do TratamentoRESUMO
We report on two patients who developed significant aortic regurgitation during transcatheter closure of a perimembranous ventricular septal defect, both requiring further surgical intervention. Both patients were noted prior to the procedure to have limited subaortic margins to the defect. The potential mechanisms for development of aortic regurgitation in this setting are discussed.
Assuntos
Insuficiência da Valva Aórtica/etiologia , Oclusão com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Comunicação Interventricular/terapia , Implantação de Prótese/efeitos adversos , Angiografia , Insuficiência da Valva Aórtica/diagnóstico , Oclusão com Balão/métodos , Cateterismo Cardíaco/métodos , Pré-Escolar , Diagnóstico Diferencial , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Comunicação Interventricular/diagnóstico , Humanos , Masculino , Implantação de Prótese/métodosRESUMO
We describe the use of a new vascular occlusion device to embolize vessels whose flow is detrimental to cardiac function in a variety of clinical situations in both adults and children with congenital cardiac disease. Our series includes four cases in which we have successfully occluded large venous vessels, to produce a beneficial effect on oxygen saturations and cardiac function. There were no adverse events because of the devices in our series, which provides evidence that the Amplatzer vascular plug is a safe and effective method of embolizing large venous vessels.