Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Drugs Dermatol ; 22(12): 1153-1159, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38051841

RESUMO

BACKGROUND: The International Dermatology Outcome Measures (IDEOM) is a non-profit organization dedicated to the advancement of evidence-based, consensus-driven outcome measures in dermatological diseases. Researchers and stakeholders from various backgrounds collaborate to develop these objective benchmark metrics to further advance treatment and management of dermatological conditions. SUMMARY: The 2022 IDEOM Annual Meeting was held on June 17-18, 2022. Leaders and stakeholders from the hidradenitis suppurativa, acne, vitiligo, actinic keratosis, alopecia areata, itch, cutaneous lymphoma, and psoriatic disease workgroups discussed the progress of their respective outcome-measures research. This report summarizes each workgroup's updates from 2022 and their next steps as established during the 2022 IDEOM Annual Meeting. J Drugs Dermatol. 2023;22(12):1153-1159 doi:10.36849/JDD.7615.


Assuntos
Alopecia em Áreas , Dermatologia , Psoríase , Neoplasias Cutâneas , Humanos , Avaliação de Resultados em Cuidados de Saúde , Psoríase/tratamento farmacológico
3.
Dermatol Surg ; 49(4): 338-342, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36763896

RESUMO

BACKGROUND: Fractional ablative laser resurfacing has been shown to improve the final cosmetic appearance of surgical scars, but optimal timing is unknown. OBJECTIVE: To compare surgical scars treated with fractional carbon dioxide (CO 2 ) laser performed on Day 0 and Day 14. METHODS: Prospective, randomized, split-scar, physician-blinded study of 30 surgical scars on the limbs. Scars halves received fractional CO 2 laser on either Day 0 or Day 14. Scar assessment at 6 months evaluated patient preference, physician modified Manchester Scar Scale (MMSS) score, and quantitative scar analysis on histology (fractal dimension [F D ] and lacunarity [L] analysis). RESULTS: There was no significant difference in patient assessment (54% preferred Day 0 side, 46% preferred Day 14 side, p = .58) or physician assessment (mean MMSS 8.4 for Day 0 vs 8.7 for Day 14, p = .28). Fractal dimensions were similar for both interventions (mean 1.778 for Day 0 vs 1.781 for Day 14, p = .80). Lacunarity was similar for both interventions (mean 0.368 for Day 0 vs 0.345 for Day 14, p = .44). LIMITATIONS: Single-center study with wounds limited to limbs of skin Phototype I-II subjects; 4 of whom were lost to follow-up. CONCLUSION: Intraoperative CO 2 laser is noninferior to Day 14 laser resurfacing for surgical scar treatment.


Assuntos
Terapia a Laser , Lasers de Gás , Neoplasias Cutâneas , Humanos , Cicatriz/etiologia , Cicatriz/cirurgia , Cicatriz/patologia , Terapia a Laser/efeitos adversos , Terapia a Laser/métodos , Lasers de Gás/uso terapêutico , Estudos Prospectivos , Neoplasias Cutâneas/cirurgia , Resultado do Tratamento
4.
J Am Acad Dermatol ; 88(2): 404-413, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-33872715

RESUMO

BACKGROUND AND OBJECTIVES: The literature supporting Mohs micrographic surgery and staged excision in treating primary cutaneous melanoma is growing but has not been critically reviewed for bias. METHODS: Articles concerning Mohs micrographic surgery and staged excision for melanoma were assessed using modified "Risk of Bias in Non-randomized Studies of Interventions" (ROBINS-I) criteria, which measures bias in 7 categories. RESULTS: Forty-seven of 48 (97.9%) studies reviewed had serious or critical bias. None were randomized controlled trials. The most frequent cause of critical bias was poorly defined outcomes. The least frequent form of bias observed was change in intervention. LIMITATIONS: The modified ROBINS-I criteria cannot account for all study limitations. Modification of the criteria leads to some degree of subjectivity. CONCLUSION: The current body of literature suffers from limitations due to serious or critical bias in 1 or more ROBINS-I criteria. Local recurrence rate definitions are often poorly defined or not defined at all. Longer follow-up times, clear tumor classifications, and prospective, randomized study designs are necessary to improve the quality of future research.


Assuntos
Melanoma , Neoplasias Cutâneas , Humanos , Melanoma/cirurgia , Melanoma/patologia , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/patologia , Cirurgia de Mohs , Estudos Prospectivos , Projetos de Pesquisa , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/cirurgia
8.
J Cutan Aesthet Surg ; 13(3): 257-258, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33209009

RESUMO

Full-thickness skin grafts harvested from hair-bearing areas may negatively impact cosmetic outcomes if the recipient site is hairless. Intraoperative depilation of unwanted hair follicles using an electrosurgical device can permanently remove hair with a single treatment and improve overall cosmesis.

9.
J Am Acad Dermatol ; 83(5): 1294-1297, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32649961

RESUMO

BACKGROUND: Platelet-rich plasma (PRP) may be a useful treatment for androgenetic alopecia (AGA), although objective studies are needed. OBJECTIVE: To determine whether PRP injections improve female AGA. METHOD: Prospective randomized controlled trial of 30 women diagnosed with AGA. Patients received subdermal scalp injections of Eclipse system PRP or placebo saline at weeks 0, 4, and 8. Outcome measures were changes in hair density (hair/cm2), hair caliber (mm), and blinded global photographic assessment (improved or not improved) at week 24. RESULTS: Blinded global photographic assessment indicated that 57% of patients receiving PRP versus 7% of patients receiving saline improved at week 24 from baseline (P < .01). Compared to baseline, there was improvement in mean density in the PRP group versus the placebo group at week 8 (+71.1 vs -26.7 hairs/cm2; P < .01) and week 24 (+105.9 vs -52.4 hairs/cm2; P < .01). Compared to baseline, there was improvement in mean caliber in the PRP group versus the placebo group at week 8 (+0.0043 vs -0.0034 mm; P < .01) and week 24 (+0.0053 vs -0.0060 mm; P < .01). Adverse effects included headache, scalp tightness, swelling, redness, and postinjection bleeding. LIMITATIONS: Two patients lost to follow-up. CONCLUSIONS: PRP with the Eclipse system is a safe and effective intervention for female AGA.


Assuntos
Alopecia/terapia , Plasma Rico em Plaquetas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Injeções Intradérmicas , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego
10.
J Cutan Med Surg ; 24(4): 367-371, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32316755

RESUMO

BACKGROUND: Hyaluronic acid (HA) fillers have increased in popularity. While complications are rare, practitioners should focus on their prevention. Preinjection aspiration remains controversial as an effective safety checkpoint. OBJECTIVES: Our study investigated the utility of preinjection aspiration as a safety checkpoint for HA fillers through comparison of physiochemical and rheological properties in a novel in vivo human model. METHODS: An in vivo human model consisted of a cannula inserted into a peripheral vein. Preinjection aspiration was evaluated using syringes of 10 commonly used HA fillers. The time required to visualize a flash was recorded. RESULTS: Using a multivariable regression model, needle gauge, HA concentration, elastic modulus (G'), viscous modulus (G″), and complex modulus (G*) had significant relationships with time to flash, whereas pullback volume did not. However, when comparing pullback volume using a more appropriate paired analysis, 0.5 cc pullback volume had a significantly decreased time to flash than 0.2 cc. CONCLUSIONS: Preinjection aspiration for HA fillers has utility as a safety checkpoint. The times to visualize flashback decreased when using a human peripheral vein model compared to a previous in vitro model, suggesting that there may be real-time clinical utility of preinjection aspiration. Waiting times to visualize flashback may be affected by physiochemical and rheological properties. Additional studies would help to validate our results.


Assuntos
Preenchedores Dérmicos/administração & dosagem , Ácido Hialurônico/administração & dosagem , Injeções Subcutâneas/métodos , Módulo de Elasticidade , Humanos , Injeções Subcutâneas/efeitos adversos , Agulhas , Reologia , Fatores de Tempo , Veias
12.
Dermatol Surg ; 45(2): 183-194, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30702447

RESUMO

BACKGROUND: Picosecond pulse duration lasers (PS) have altered the field of dermatology. PS were initially used in tattoo removal, to optimize efficacy and reduce side effects with nanosecond domain lasers. More recently, they have been demonstrated to be effective in the treatment of pigmentary disorders, acne scarring, and photoaging. OBJECTIVE: In this article, we critically analyze the published data on the many uses of picosecond lasers in dermatology. MATERIALS AND METHODS: A systematic review of PubMed was conducted using the following search terms: "picosecond," "picosecond laser," "picosecond laser dermatology," "picosecond laser pigment/pigmentation," and "picosecond laser tattoo removal." Articles ranged from 1988 until 2017. RESULTS: Forty-one articles were identified, and 27 met inclusion criteria for review. Indications for the PS included a variety of dermatologic applications include tattoo removal, benign pigmented lesions/pigmentary disorders, acne scarring, and photoaging. Most studies demonstrated safe and effective treatment. CONCLUSION: The development of the picosecond pulse duration is a breakthrough innovation in laser technology, changing the scope of laser treatment. Encouraging findings in tattoo pigment clearance spurred the use of PS in a wider array of dermatologic issues. The increasingly positive results and low incidence of adverse effects further substantiates PS efficacy for a variety of dermatologic uses.


Assuntos
Dermatologia/tendências , Lasers de Estado Sólido/uso terapêutico , Transtornos da Pigmentação/radioterapia , Humanos
13.
Dermatol Surg ; 45(7): 954-958, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30624257

RESUMO

BACKGROUND: Hyaluronic acid (HA) fillers have increased in popularity. Although complications are rare, knowledge regarding their prevention and management are crucial. The utility of preinjection aspiration has become controversial. OBJECTIVE: Our study investigated the utility of preinjection aspiration as a safety checkpoint for HA fillers through comparison of physiochemical and rheological properties in an in vitro model. MATERIALS AND METHODS: Whole blood was drawn from vacutainers using syringes containing 10 commonly used HA fillers. Each HA filler was examined with the plunger pulled back at volumes of 0.2 and 0.5 cc. The time required to visualize a flash was recorded. Data were compared using physiochemical and rheological properties, pullback volumes, and needle gauges. RESULTS: Using a multivariable regression model, HA concentration, elastic modulus (G'), viscous modulus (G″), and complex modulus (G*) had significant relationships with time to flash, whereas needle gauge and pullback volume did not. However, when comparing pullback volume using an appropriate paired analysis, 0.5 cc pullback volume had a significantly decreased mean time to flash than 0.2 cc. CONCLUSION: Preinjection aspiration may have utility as a safety checkpoint for HA fillers. Practitioners may have to adjust pullback volume and waiting time to visualize the flash based on physiochemical and rheological properties.


Assuntos
Preenchedores Dérmicos/administração & dosagem , Ácido Hialurônico/administração & dosagem , Injeções Subcutâneas/métodos , Viscossuplementos/administração & dosagem , Técnicas Cosméticas , Preenchedores Dérmicos/farmacocinética , Humanos , Ácido Hialurônico/farmacocinética , Paracentese , Técnicas de Cultura de Tecidos , Viscossuplementos/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA