Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol Open ; 10: 100470, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36590327

RESUMO

Rationale and objectives: Patients receiving high cumulative effective doses (CED) from recurrent computed tomography (CT) in a real-life setting are not well identified. Evaluation of causes and patient characteristics may help to define individuals potentially at risk of radiation-induced secondary malignancies. Materials and methods: Patients who received a CED > 100 mSv from CT scans during October 2012 and April 2020 at a tertiary university center were identified with the help of a radiological radiation dose monitoring system. The primary disease and referral diagnosis, number of CT exams, time period, age, BMI and gender distribution of the 1000 patients with the highest CED were analysed. Results: 3431 patients had a CED of more than 100 mSv, which corresponded to 2.75% of all patients who received a CT exam. From the 1000 patients with the highest CED, mean number of CT exams per patient was 14.6, mean CED was 257 mSv (SD 98, range 177-1339). Mean age of patients was 63.9 years (SD 10.6), male to female ratio 3:2, and mean BMI 28.7 kg/m2 (SD 5.5). 728 (72.9%) patients had cancer. The leading primary diagnosis was liver cirrhosis in 197 patients and 103 patients had a liver transplantation. In patients with liver cirrhosis, 750 exams were indicated for the follow-up of the disease, 662 for the clarification of an acute clinical condition, and 202 for CT-guided stereotactic radiofrequency ablation. Conclusion: Recurrent CT scans of patients with cancer, liver cirrhosis and liver transplantation may lead to critically high CED.

2.
J Biomed Opt ; 16(3): 036007, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21456870

RESUMO

In the present study, we evaluated the applicability of ex vivo photoacoustic imaging (PAI) on small animal organs. We used photoacoustic tomography (PAT) to visualize infarcted areas within murine hearts and compared these data to other imaging techniques [magnetic resonance imaging (MRI), micro-computed tomography] and histological slices. In order to induce ischemia, an in vivo ligation of the left anterior descending artery was performed on nine wild-type mice. After varying survival periods, the hearts were excised and fixed in formaldehyde. Samples were illuminated with nanosecond laser pulses delivered by a Nd:YAG pumped optical parametric oscillator. Ultrasound detection was achieved using a Mach-Zehnder interferometer (MZI) working as an integrating line detector. The voxel data were computed using a Fourier-domain based reconstruction algorithm, followed by inverse Radon transforms. The results clearly showed the capability of PAI to visualize myocardial infarction and to produce three-dimensional images with a spatial resolution of approximately 120 µm. Regions of affected muscle tissue in PAI corresponded well with the results of MRI and histology. Photoacoustic tomography utilizing a MZI for ultrasound detection allows for imaging of small tissue samples. Due to its high spatial resolution, good soft tissue contrast and comparatively low cost, PAT offers great potentials for imaging.


Assuntos
Infarto do Miocárdio/diagnóstico , Tomografia Óptica/métodos , Acústica , Animais , Modelos Animais de Doenças , Técnicas Histológicas , Imageamento Tridimensional , Interferometria , Imageamento por Ressonância Magnética , Camundongos , Camundongos Endogâmicos C57BL , Infarto do Miocárdio/diagnóstico por imagem , Fenômenos Ópticos , Ultrassonografia , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA