Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38475980

RESUMO

The effect of coagulant dosage in a chemically enhanced primary treatment (CEPT) on the performance of a conventional wastewater treatment plant (WWTP) has been investigated. Lab-scale experiments simulations were carried out in order to evaluate the effect of coagulant addition on the primary settling performance. In these experiments, FeCl3 was used as coagulant. Later, the WWTP was theoretically simulated using a commercial software (WEST®) to evaluate the effect of coagulation/flocculation on the global system, based on the results obtained at lab-scale. According to these results, the CEPT modifies the organic matter balance in the WWTP, decreasing the contribution of readily (SS) and slowly (XS) biodegradable fractions of COD to the aerobic biological process up to 27.3% and 80.8%, respectively, for a dosage of FeCl3 of 24 mg L-1. Consequently, total suspended solids in the aerobic reactor and the secondary purged sludge decreased up to 33% and 13%, respectively. However, the influence on effluent quality was negligible. On the contrary, suspended solids concentration in the sludge to be treated by anaerobic digestion increased, mainly regarding the Ss and Xs fractions, which caused an 8.1% increase in biogas production potential, with approximately 60% of CH4 concentration.


Assuntos
Compostos Férricos , Esgotos , Águas Residuárias , Esgotos/química , Eliminação de Resíduos Líquidos/métodos , Cloretos