Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 83(10): 10D535, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126873

RESUMO

This paper describes the measurement of the density fluctuation using beam emission spectroscopy in Heliotron J, having the non-symmetrical helical-magnetic-axis configuration. In order to optimize the sightlines, the numerical calculations are carried out to estimate the spatial resolution and the observation location. When a tangential neutral beam is used as diagnostic one, suitable sightlines from the newly installed diagnostic port are selected whose spatial resolution Δρ is less than ± 0.07 over the entire plasma region. Modification of the interference filter and the detection systems enables us to measure the radial profile of the density fluctuation. Each of the three coherent modes due to the fast-ion-driven magnetohydrodynamic instabilities has different radial structure of the density fluctuation.


Assuntos
Análise Espectral/métodos , Hidrodinâmica , Fenômenos Magnéticos , Dispositivos Ópticos , Análise Espectral/instrumentação , Fatores de Tempo
2.
Rev Sci Instrum ; 81(10): 10D726, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033919

RESUMO

This paper describes the application of the beam emission spectroscopy (BES) to Heliotron J, having the nonsymmetrical helical-magnetic-axis configuration. The spectral and spatial profile of the beam emission has been estimated by the numerical calculation taking the collisional excitation processes between plasmas (electrons/ions) and beam atoms. Two sets of the sightlines with good spatial resolution are presented. One is the optimized viewing chords which have 20 sightlines and observe the whole plasma region with the spatial resolution Δρ less than ±0.055 using the newly designed viewing port. The other is 15 sightlines from the present viewing port of Heliotron J for the preliminary measurement to discuss the feasibility of the density fluctuation measurement by BES. The beam emission has been measured by a monochromator with a CCD camera. A good consistency has been obtained between the spectral profiles of the beam emission measured by the monochromator and the beam emission spectrum deduced by the model calculation. An avalanche photodiode with an interference filter system was also used to evaluate the signal-to-noise (S/N) ratio of the beam emission in the present experimental setup. The modification of the optical system is being planned to improve the S/N ratio, which will enable us to estimate the density fluctuation in Heliotron J.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA