RESUMO
Background: Diagnosis of Brugada syndrome (BrS) may be established by exposing a Type 1 Brugada pattern using a sodium channel blocker. Data on the outcomes of different patient populations with drug-induced Type 1 Brugada pattern are limited. The present study reports on the characteristics and outcome of subjects with ajmaline induced Type 1 Brugada pattern. Methods: A multicenter retrospective study including all consecutive cases of ajmaline-induced Type 1 Brugada pattern from seven centers. Results: A total of 260 patients (69.9% males, mean age 43.4 ± 13.5) were included. Additional characteristics included history of syncope (n = 56, 21.5%), family history of BrS (n = 58, 22.3%) or sudden cardiac death (n = 47, 18.1%) and ventricular fibrillation (n = 3, 1.2%). Patients were divided into those meeting current diagnostic criteria for drug-induced BrS (DIBrS) and compared to the drug-induced Brugada pattern (DIBrECG). Females were significantly overrepresented in the DIBrS group (n = 50, 40% vs. n = 29, 21.5%, p = .001). A significantly higher prevalence of type 2/3 Brugada ECG at baseline was found in the DIBrECG group (n = 108, 80.8% vs. n = 75, 60% in the DIBrS, p = .026). During a median follow up of three (IQR 1.50-5.32) years, a single event of significant arrhythmia occurred in the DIBrS group. Conclusion: Less than half of subjects with ajmaline-induced Brugada pattern met current criteria for BrS. These individuals had very low rate of adverse outcomes during a follow up of 3 years, irrespective of the indication for the test or eligibility for the BrS diagnosis.
RESUMO
BACKGROUND: Management of acute myocarditis (AM) patients experiencing ventricular arrhythmia (VA) during acute illness is controversial, especially regarding early implantable cardioverter-defibrillator (ICD) implantation. OBJECTIVES: The purpose of this study was to evaluate the prevalence of and find predictors for long-term sustained VA recurrence and overall mortality among AM patients with VA. METHODS: This was a multicenter retrospective analysis of AM patients (verified by cardiac magnetic resonance imaging or myocardial biopsy) with documented VA during the acute illness ("initial VA"). Patients with history of myocardial infarction, heart failure, or VA were excluded. The study endpoint was a composite of sustained VA and overall mortality during follow-up. RESULTS: The study included 69 AM patients with initial VA: sustained monomorphic ventricular tachycardia (MMVT) (n = 25), sustained polymorphic ventricular tachycardia (VT)/ventricular fibrillation (n = 13), and nonsustained VT (n = 31). Age was 44 ± 13 years, and 23 of 69 (33.3%) were women. During median follow-up of 5.5 years, 27 of 69 (39%) patients reached the composite endpoint including sustained VA (n = 24) and death (n = 11). Initial MMVT, predischarge left ventricular dysfunction (left ventricular ejection fraction <50%), and anteroseptal delayed enhancement on cardiac magnetic resonance imaging were significantly associated with the composite endpoint. On multivariable analysis, initial MMVT (HR: 5.17; 95% CI: 1.81-14.6; P = 0.001) and predischarge LV dysfunction (HR: 4.57; 95% CI: 1.83-11.5; P = 0.005) were independently associated with the composite endpoint. Using these 2 predictors, we could delineate subgroups with low (â¼4%), medium (â¼42%), and high (â¼82%) 10-year incidence of composite endpoint. CONCLUSIONS: AM patients presenting with VA have high incidence of sustained VA recurrence and mortality posthospitalization. Initial MMVT and predischarge LV dysfunction are independently associated with VA recurrence and mortality. Implantable cardioverter-defibrillator implantation may be considered in such high-risk patients.
Assuntos
Miocardite , Recidiva , Taquicardia Ventricular , Humanos , Feminino , Masculino , Miocardite/epidemiologia , Miocardite/complicações , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Incidência , Desfibriladores Implantáveis , Doença Aguda , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/terapiaRESUMO
BACKGROUND: Prior studies evaluating post-atrial fibrillation (AF) ablation pulmonary vein (PV) ostial gaps via magnetic resonance imaging (MRI) have shown circumferential PV fibrosis in a minority of patients, and their correlation with AF recurrence was weak. These studies were mostly based on radio-frequency AF ablations. AIM: We aimed to assess cryoballoon ablation-induced PV fibrosis via MRI and its correlation with AF recurrence. METHODS AND RESULTS: This was a prospective study of consecutive patients with symptomatic AF who underwent pre- and post-ablation MRI to assess baseline and ablation-induced fibrosis, respectively. Post-ablation PV gaps were assessed by new semi-quantitative visual analysis assisted by computerized ADAS analysis. AF recurrence monitored via multiple ECGs and event monitoring at 6 and 12 months post ablation. Nineteen patients with 80 PVs were included, age 56 ± 11, with paroxysmal and persistent AF in 17/19 and 2/19 patients, respectively. Baseline MRI showed minimal LA fibrosis. All patients underwent successful cryoballoon PV electrical isolation. Post-ablation MRI revealed circumferential PV fibrosis among 63/80 (78.8%) PVs and partial fibrosis with major gaps among 17/80 (21.2%) PVs. AF recurred within one year in 5/9 (55.5%) patients with partial PV fibrosis, while no AF recurred among the 10 patients in whom all PVs had circumferential fibrosis (p < 0.01). Similarly, there were significantly more PVs without circumferential fibrosis (due to major gaps) among patients with AF recurrence as compared with patients without AF recurrence (42.9% vs. 13.5%; p < 0.01). CONCLUSION: Cryoballoon AF ablation results in circumferential PV fibrosis in the majority of PVs, as assessed by a new clinically relevant MRI-LGE analysis. Significant correlation was found between major PV gaps on post-ablation MRI and AF recurrence, suggesting that MRI might have the ability to predict AF recurrence.
RESUMO
AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data. METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available. Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV. CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants.
Assuntos
Cardiomiopatias , Taquicardia Ventricular , Humanos , Bloqueio de Ramo , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/complicações , Ventrículos do Coração , Eletrocardiografia , Cardiomiopatias/complicações , Cardiomiopatias/diagnósticoRESUMO
AIMS: Conduction abnormalities post-transcatheter aortic valve implantation (TAVI) are common. Post-TAVI PR prolongation was mainly studied as an adjunct to new-onset bundle branch block. The net effect of isolated PR prolongation (IPRP) without post-TAVI QRS changes is not well known. The aim of this study was to define the incidence and clinical significance of post-TAVI IPRP. METHODS AND RESULTS: A total of 1108 consecutive TAVI patients were reviewed. Patients with IPRP were compared with patients without post-TAVI electrocardiogram (ECG) changes. Clinical outcomes included permanent pacemaker implantation (PPI) and overall mortality. A total of 146 patients with IPRP were compared with 290 patients without post-TAVI ECG changes. At 1 year follow-up, 4 (2.7%) and 7 (2.4%) patients underwent PPI (P = 0.838) and 10 (6.8%) and 25 (8.6%) died (P = 0.521), from the study and control groups, respectively. No patient with IPRP and narrow QRS underwent PPI during 1 year post-TAVI, and all death events were non-cardiac except one unknown cause. Permanent pacemaker implantation rates among patients with IPRP and wide QRS were higher (n = 4, 12.1%), compared with patients with wide QRS without post-TAVI ECG change (n = 3, 4%) however not reaching statistical significance (P = 0.126). Multivariate Cox proportional hazards model demonstrated that in patients with narrow QRS, neither PR prolongation nor baseline or maximal PR intervals was associated with the combined endpoint of PPI and mortality. However, in patients with wide QRS, baseline PR intervals and QRS width, but not PR prolongation were associated with the combined outcome. CONCLUSION: Post-TAVI IPRP in patients with narrow QRS is not associated with adverse outcome. This finding may translate clinically into a more permissive approach to these patients.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Incidência , Relevância Clínica , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Eletrocardiografia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversosRESUMO
Idiopathic ventricular fibrillation is responsible for ≈5%-7% of aborted cardiac arrest, mainly striking subjects in their forties. Syncope caused by short-coupled rapid polymorphic ventricular tachycardia is frequently noted in a patient's past history. However, a diagnosis of neurally mediated syncope, the most frequent cause of syncope in the young, is often erroneously made. Clinical clues suggest that syncope has an arrhythmic rather than a neurally mediated origin. In addition, the presence of premature ventricular contractions on an electrocardiogram recorded shortly after a syncopal event has utmost importance in establishing the cause of syncope. Although such extrasystoles are frequently benign, especially when associated with a long coupling interval, they also may suggest a malignant origin when closely coupled to the preceding complex with short coupling intervals (usually <350 ms). These arrhythmias mainly originate from the Purkinje system (usually the right ventricle in men and the left ventricle in women) and favorably respond to quinidine as well as to ablation therapy targeting Purkinje-fibers ectopic activity.
Assuntos
Taquicardia Ventricular , Complexos Ventriculares Prematuros , Feminino , Humanos , Masculino , Eletrocardiografia , Síncope/diagnóstico , Síncope/etiologia , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/complicaçõesRESUMO
Idiopathic ventricular fibrillation is responsible for approximately 5%-7% of cases of aborted cardiac arrest. Recent studies have shown that short-coupled ventricular premature complexes are present at the onset of idiopathic ventricular fibrillation in 6.6%-17% of patients. The present review provided information on 86 patients with short-coupled malignant ventricular arrhythmias that were reported as case reports or small patient series during the last 70 years. In 75% of the 81 cases published during the last 40 years, extended information and follow-up (from 2.63 ± 4.5 years to 10.67 ± 7.8 years; P < 0.001, between the original publication to the latest update) could be obtained from the authors. The review shows that short-coupled malignant ventricular arrhythmias occurred almost equally in males and females, at the mean age of 40 years. A tendency for later occurrence of the arrhythmia by 4 years was observed in females. A prior history of syncope was noted in 45.3% of the patients, whereas arrhythmic storm occurred in 42% at presentation. The most common mode of revelation of short-coupled malignant ventricular arrhythmias was syncope (53.5%), followed by aborted cardiac arrest (26.7%) and recurrent arrhythmic event after prior implantable-cardioverter defibrillator implantation for idiopathic ventricular fibrillation (17.4%). For the first time, short-coupled malignant arrhythmias exhibiting "not-so-short" coupling intervals (≥350 milliseconds) were found in a significant proportion of patients (17.4%). During long-term follow-up, quinidine yielded a slightly higher success rate in arrhythmia control than ablation. Larger studies are necessary to assess the best strategy for the management of this potentially lethal arrhythmia.
Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Adulto , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/epidemiologia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Síncope , Fibrilação VentricularRESUMO
BACKGROUND: A novel 3D mapping system (KODEX-EPD, EPD Solutions) enables catheter localization and real-time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX-EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX-EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland-Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland-Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX-EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Computadores , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.
Assuntos
Bloqueio Atrioventricular , COVID-19 , Controle de Infecções , Complicações Pós-Operatórias , Implantação de Prótese , SARS-CoV-2/isolamento & purificação , Síndrome do Nó Sinusal , Idoso , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/terapia , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/terapia , Comorbidade , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Saúde Global/estatística & dados numéricos , Humanos , Controle de Infecções/instrumentação , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Masculino , Pessoa de Meia-Idade , Mortalidade , Avaliação de Resultados em Cuidados de Saúde , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Fatores de Risco , Síndrome do Nó Sinusal/epidemiologia , Síndrome do Nó Sinusal/terapia , Inquéritos e QuestionáriosRESUMO
AIMS: The aims of this study is to characterize the transvenous lead extraction (TLE) population with active (A) compared with passive fixation (PFix) leads and to compare the safety, efficacy, and ease of extracting active fixation (AFix) compared with PFix right atrial (RA) and right ventricular (RV) leads. METHODS AND RESULTS: The European Lead Extraction ConTRolled Registry (ELECTRa) was analysed. Patients were divided into three groups; those with only AFix, only PFix, and combined Fix leads. Three outcomes were defined. Difficult extraction, complete radiological, and clinical success. Multivariate model was used to analyse the independent effect of Fix mechanism on these outcomes. The study included 2815 patients, 1456 (51.7%) with only AFix leads, 982 (34.9%) with only PFix leads, and 377 (13.4%) with combined Fix leads. Patients with AFix leads were younger with shorter lead dwelling time. Infection was the leading cause for TLE among the combined Fix group with lowest rates among AFix group. No difference in complications rates was noted between patients with only AFix vs. PFix leads. Overall, there were 1689 RA (1046 AFix and 643 PFix) and 2617 RV leads (1441 AFix and 1176 PFix). Multivariate model demonstrated that PFix is independently associated with more difficult extraction for both RA and RV leads, lower radiological success in the RA but has no effect on clinical success. CONCLUSION: Mechanism of Fix impact the ease of TLE of RA and RV leads and rates of complete radiological success in the RA but not clinical success. These findings should be considered during implantation and TLE procedures.
Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Humanos , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Resultado do TratamentoRESUMO
AIMS: Distinctive types of polymorphic ventricular tachycardia (VT) respond differently to different forms of therapy. We therefore performed the present study to define the electrocardiographic characteristics of different forms of polymorphic VT. METHODS AND RESULTS: We studied 190 patients for whom the onset of 305 polymorphic VT events was available. The study group included 87 patients with coronary artery disease who had spontaneous polymorphic VT triggered by short-coupled extrasystoles in the absence of myocardial ischaemia. This group included 32 patients who had a long QT interval but nevertheless had their polymorphic VT triggered by ectopic beats with short coupling interval, a subcategory termed 'pseudo-torsade de pointes] (TdP). For comparison, we included 50 patients who had ventricular fibrillation (VF) during acute myocardial infarction ('ischaemic VF' group) and 53 patients with drug-induced TdP ('true TdP' group). The QT of patients with pseudo-TdP was (by definition) longer than that of patients with polymorphic VT and normal QT (QTc 491.4 ± 25.2 ms vs. 447.3 ± 55.6 ms, P < 0.001). However, their QT was significantly shorter than that of patients with true TdP (QTc 564.6 ± 75.6 ms, P < 0.001). Importantly, the coupling interval of the ectopic beat triggering the arrhythmia was just as short during pseudo-TdP as during polymorphic VT with normal QT (359.1 ± 38.1 ms vs. 356.6 ± 39.4 ms, P = 0.467) but was much shorter than during true TdP (581.2 ± 95.3 ms, P < 0.001). CONCLUSIONS: The coupling interval helps discriminate between polymorphic VT that occurs despite a long QT interval (pseudo-TdP) and polymorphic arrhythmias striking because of a long QT (true TdP).
Assuntos
Síndrome do QT Longo , Taquicardia Ventricular , Torsades de Pointes , Diagnóstico Diferencial , Eletrocardiografia , Humanos , Síndrome do QT Longo/diagnóstico , Taquicardia Ventricular/diagnóstico , Torsades de Pointes/diagnóstico , Torsades de Pointes/etiologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologiaRESUMO
New conduction disturbances requiring permanent pacemaker implantation remain common complications following transcatheter aortic valve implantation (TAVI). It has been suggested that electrophysiological studies could help identify patients who will require permanent pacemaker implantation after TAVI. This article summarises contemporary data on the use of electrophysiological studies in patients undergoing TAVI.
RESUMO
BACKGROUND: Patients with right bundle branch block (RBBB) prior to transcatheter aortic valve implantation (TAVI) are at high risk for immediate post-procedural heart block and long-term mortality when discharged without a pacemaker. OBJECTIVES: To test whether prophylactic permanent pacemaker implantation (PPI) is beneficial. METHODS: Of 795 consecutive patients who underwent TAVI, 90 patients had baseline RBBB. We compared characteristics and outcomes of the prophylactic PPI with post-TAVI PPI. Need for pacing was defined as greater than 1% ventricular pacing. RESULTS: Forty patients with RBBB received a prophylactic PPI (group 1), and in 50 the decision was based on standard post-procedural indications (group 2). There were no significant differences in clinical baseline characteristics. One patient developed a tamponade after a PPI post-TAVI. A trend toward shorter hospitalization duration in group 1 patients was observed (P = 0.06). On long-term follow-up of 848 ± 56 days, no differences were found in overall survival (P = 0.77), the composite event-free survival of both mortality and hospitalizations (P = 0.66), or mortality and syncope (P = 0.65). On multivariate analysis, independent predictors of the need for pacing included baseline PR interval increase of 10ms (odds ratio [OR] 1.21 per 10 ms increment 95% confidence interval [95%CI] 1.02-1.44, P = 0.028), and the use of new generation valves (OR 3.92, 95%CI 1.23-12.46, P = 0.023). CONCLUSIONS: In patients with baseline pre-TAVI RBBB, no outcome differences were found with prophylactic PPI. On multivariate analysis, predictors of the need for pacing included baseline long PR interval, and the use of newer generation valves.
Assuntos
Bloqueio de Ramo , Estimulação Cardíaca Artificial , Complicações Pós-Operatórias , Cuidados Pré-Operatórios/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Feminino , Humanos , Israel/epidemiologia , Tempo de Internação/estatística & dados numéricos , Masculino , Mortalidade , Avaliação de Processos e Resultados em Cuidados de Saúde , Marca-Passo Artificial , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/prevenção & controle , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodosRESUMO
BACKGROUND: Polymorphic ventricular tachycardia (VT) without QT prolongation is well described in patients without structural heart disease (mainly idiopathic ventricular fibrillation and Brugada syndrome) and in patients with acute ST-elevation myocardial infarction. METHODS: Retrospective study of patients with polymorphic VT related to coronary artery disease, but without evidence of acute myocardial ischemia. RESULTS: The authors identified 43 patients in whom polymorphic VT developed within days of an otherwise uncomplicated myocardial infarction or coronary revascularization procedure. The polymorphic VT events were invariably triggered by extrasystoles with short (364±36 ms) coupling interval. Arrhythmic storms (4-16 events of polymorphic VT deteriorating to ventricular fibrillation) occurred in 23 (53%) patients. These arrhythmic storms were always refractory to conventional antiarrhythmic therapy, including intravenous amiodarone, but invariably responded to quinidine therapy. In-hospital mortality was 17% for patients with arrhythmic storm. Patients treated with quinidine invariably survived to hospital discharge. During long-term follow-up (of 5.6±6 years; range, 1 month to 18 years), 3 (16%) of patients discharged without quinidine developed recurrent polymorphic VT. There were no recurrent arrhythmias during quinidine therapy Conclusions: Arrhythmic storm with recurrent polymorphic VT in patients with coronary disease responds to quinidine therapy when other antiarrhythmic drugs (including intravenous amiodarone) fail.
Assuntos
Antiarrítmicos/uso terapêutico , Doença da Artéria Coronariana/complicações , Quinidina/uso terapêutico , Taquicardia Ventricular/tratamento farmacológico , Idoso , Amiodarona/farmacologia , Amiodarona/uso terapêutico , Antiarrítmicos/efeitos adversos , Antiarrítmicos/farmacologia , Avaliação de Medicamentos , Resistência a Medicamentos , Substituição de Medicamentos , Eletrocardiografia , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Revascularização Miocárdica , Complicações Pós-Operatórias/tratamento farmacológico , Quinidina/efeitos adversos , Recidiva , Estudos Retrospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Trombocitopenia/induzido quimicamente , Fibrilação Ventricular/etiologia , Complexos Ventriculares Prematuros/etiologiaRESUMO
BACKGROUND: The incidence, characteristics, and clinical significance of catheter-induced mechanical suppression (trauma) of ventricular arrhythmias originating in the outflow tract (OT) area have not been thoroughly evaluated. OBJECTIVES: To determine these variables among our patient cohort. METHODS: All consecutive patients with right ventricular OT (RVOT) and left ventricular OT (LVOT) arrhythmias ablated at two medical centers from 1998 to 2014 were included. Patients were observed for catheter-induced trauma during ablation procedures. Procedural characteristics, as well as response to catheter-induced trauma and long term follow-up, were recorded. RESULTS: During 288 ablations of OT arrhythmias in 273 patients (RVOT n=238, LVOT n=50), we identified 8 RVOT cases (3.3%) and 1 LVOT (2%) case with catheter-induced trauma. Four cases of trauma were managed by immediate radiofrequency ablation (RFA), three were ablated after arrhythmia recurrence within a few minutes, and two were ablated after > 30 minutes without arrhythmia recurrence. Patients with catheter-induced trauma had higher rates of repeat ablations compared to patients without: 3/9 (33%) vs. 12/264 (0.45%), P = 0.009. The three patients with arrhythmia recurrence were managed differently during the first ablation procedure (immediate RFA, RFA following early recurrence, and delayed RFA). During the repeat procedure of these three patients, no catheter trauma occurred in two, and in one no arrhythmia was observed. CONCLUSIONS: Significant catheter-induced trauma occurred in 3.1% of OT arrhythmias ablations, both at the RVOT and LVOT. Arrhythmia suppression may last > 30 minutes and may interfere with procedural success. The optimal mode of management following trauma is undetermined.
Assuntos
Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ventrículos do Coração/fisiopatologia , Complicações Intraoperatórias/epidemiologia , Adulto , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Feminino , Seguimentos , Ventrículos do Coração/cirurgia , Humanos , Incidência , Complicações Intraoperatórias/cirurgia , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Left posterior fascicular ventricular tachycardia (LPF-VT) is frequently misdiagnosed as supraventricular tachycardia with aberrant right bundle branch block (RBBB) and left anterior hemiblock (LAHB). The purpose of the present study was to define the morphological ECG characteristics of LPF-VT and attempt to differentiate it from RBBB and LAHB aberrancy. METHODS AND RESULTS: A systematic Medline search was used to identify or locate ECG tracings from patients with LPF-VTs. ECGs with LPF-VT were also collected from patients who underwent ablation of this arrhythmia at the Tel Aviv and Sheba Medical Centers. These ECGs were compared with ECGs of consecutive patients with RBBB and LAHB and no obvious cardiac pathology by echocardiography. Overall, 183 ECGs of LPF-VT were compared with 61 ECGs showing RBBB and LAHB. Univariate analysis demonstrated differences in QRS axis, limb (I, aVr), and precordial (V1, V2, V6) ECG leads. On multivariate logistic regression analysis, LPF-VT was more often associated with atypical RBBB-like V1 morphology (odds ratio, 5.1; P=0.004), positive QRS in aVr (odds ratio, 19.2; P<0.001), V6 R/S ratio ≤1 (odds ratio, 6.7; P=0.01), and QRS ≤140 ms (odds ratio, 7.7; P<0.001). Using these 4 variables, a prediction model was developed that predicted LPF-VT with sensitivity and specificity of 82.1% and 78.3%, respectively. Patients with 3 of 4 positive variables had high probability of having LPF-VT, whereas patients with ≤1 positive variable always had RBBB plus LAHB. CONCLUSIONS: The morphological ECG characteristics of LPF-VT were defined, and a high accurate tool for correctly differentiating LPF-VT from RBBB and LAHB aberrancy was developed.