Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Terahertz Sci Technol ; 12(2): 151-164, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36185397

RESUMO

A system concept for online alignment verification of millimeter-wave, corneal reflectometry is presented. The system utilizes beam scanning to generate magnitude-only reflectivity maps of the cornea at 650 GHz and compares these images to a precomputed/measured template map to confirm/reject sufficient alignment. A system utilizing 5 off-axis parabolic mirrors, a thin film beam splitter, and 2-axis galvanometric mirror was designed, simulated, and evaluated with geometric and physical optics. Simulation results informed the construction of a demonstrator system which was tested with a reference reflector. Similarity metrics computed with the aligned template and 26 misaligned positions, distributed on a 0.5 mm x 0.5 mm x 0.5 mm mesh, demonstrated sufficient misalignment detection sensitivity in 23 out of 26 positions. The results show that positional accuracy on the order of 0.5 mm is possible using 0.462 mm wavelength radiation due to the perturbation of coupling efficiency via beam distortion and beam walk-off.

2.
Sci Rep ; 11(1): 10297, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33986450

RESUMO

Existing paradigms for stroke diagnosis typically involve computed tomography (CT) imaging to classify ischemic versus hemorrhagic stroke variants, as treatment for these subtypes varies widely. Delays in diagnosis and transport of unstable patients may worsen neurological status. To address these issues, we describe the development of a rapid, portable, and accurate eddy current damping (ECD) stroke sensor. Copper wire was wound to create large (11.4 cm), medium (4.5 cm), and small (1.5 cm) solenoid coils with varying diameters, with each connected to an inductance-to-digital converter. Eight human participants were recruited between December 15, 2019 and March 15, 2020, including two hemorrhagic stroke, two ischemic stroke, one subarachnoid hemorrhage, and three control participants. Observers were blinded to lesion type and location. A head cap with 8 horizontal scanning paths was placed on the patient. The sensor was tangentially rotated across each row on the patient's head circumferentially. Consent, positioning, and scanning with the sensor took roughly 15 min from start to end for each participant and all scanning took place at the patient bedside. The ECD sensor accurately classified and imaged each of the varying stroke types in each patient. The sensor additionally detected ischemic and hemorrhagic lesions located deep inside the brain, and its range is selectively tunable during sensor design and fabrication.


Assuntos
Acidente Vascular Cerebral/classificação , Tomografia Computadorizada por Raios X/métodos , Adulto , Animais , Feminino , Cobaias , Humanos , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA