Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(3): 033906, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35364976

RESUMO

Angle-resolved photoemission spectroscopy using a micro-focused beam spot [micro-angle-resolved photoemission spectroscopy (ARPES)] is becoming a powerful tool to elucidate key electronic states of exotic quantum materials. We have developed a versatile micro-ARPES system based on the synchrotron radiation beam focused with a Kirkpatrick-Baez mirror optics. The mirrors are monolithically installed on a stage, which is driven with five-axis motion, and are vibrationally separated from the ARPES measurement system. Spatial mapping of the Au photolithography pattern on Si signifies the beam spot size of 10 µm (horizontal) × 12 µm (vertical) at the sample position, which is well suited to resolve the fine structure in local electronic states. Utilization of the micro-beam and the high precision sample motion system enables the accurate spatially resolved band-structure mapping, as demonstrated by the observation of a small band anomaly associated with tiny sample bending near the edge of a cleaved topological insulator single crystal.

2.
J Synchrotron Radiat ; 29(Pt 2): 400-408, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35254303

RESUMO

Beamline 13 of the Photon Factory has been in operation since 2010 as a vacuum ultraviolet and soft X-ray undulator beamline for X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XAS), and angle-resolved photoelectron spectroscopy (ARPES) experiments. The beamline and the end-station at branch B have been recently upgraded, enabling microscopic XPS, XAS, and ARPES measurements to be performed. In 2015, a planar undulator insertion device was replaced with an APPLE-II (advanced planar polarized light emitter II) undulator. This replacement allows use of linear, circular, and elliptical polarized light between 48 and 2000 eV with photon intensities of 109-1013 photons s-1. For microscopic measurements, a toroidal post-mirror was renewed to have more focused beam with profile sizes of 78 µm (horizontal) × 15 µm (vertical) and 84 µm × 11 µm at photon energies of 100 and 400 eV, respectively. A high-precision sample manipulator composed of an XYZ translator, a rotary feedthrough, and a newly developed goniometer, which is essential for microscopic measurements, has been used to control a sample specimen in six degrees of freedom, i.e. translation in the X, Y, and Z directions and rotation in the polar, azimuthal, and tilt directions. To demonstrate the performance of the focused beams, one- and two-dimensional XPS and XAS scan measurements of a copper grid have been performed. It was indicated from analysis of XPS and XAS intensity maps that the actual spatial resolution can be determined by the beam size.

3.
J Synchrotron Radiat ; 28(Pt 1): 86-90, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399556

RESUMO

At a soft X-ray beamline with an undulator source, significant heat generation at the first-mirror chamber and light emission at the viewport were found, which can be explained by photoelectrons from the mirror. The chamber temperature increases up to approximately 50°C over a period of several hours. A photoelectron shield consisting of thin copper plates not only prevents the heat generation and light emission but also improves the pressure of the vacuum chamber, if a voltage of a few tens of V is applied to the shield. The total electron yield of the shield reached as much as 58 mA under high heat-load conditions, indicating the emission of numerous photoelectrons from the first mirror. Heat-balance analyses suggest that approximately 30% or more of the heat load on the first mirror is transferred to the surroundings.

4.
J Synchrotron Radiat ; 22(6): 1359-63, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524299

RESUMO

Carbon-free chromium-coated optics are ideal in the carbon K-edge region (280-330 eV) because the reflectivity of first-order light is larger than that of gold-coated optics while the second-order harmonics (560-660 eV) are significantly suppressed by chromium L-edge and oxygen K-edge absorption. Here, chromium-, gold- and nickel-coated mirrors have been adopted in the vacuum ultraviolet and soft X-ray branch beamline BL-13B at the Photon Factory in Tsukuba, Japan. Carbon contamination on the chromium-coated mirror was almost completely removed by exposure to oxygen at a pressure of 8 × 10(-2) Pa for 1 h under irradiation of non-monochromated synchrotron radiation. The pressure in the chamber recovered to the order of 10(-7) Pa within a few hours. The reflectivity of the chromium-coated mirror of the second-order harmonics in the carbon K-edge region (560-660 eV) was found to be a factor of 0.1-0.48 smaller than that of the gold-coated mirror.

5.
J Synchrotron Radiat ; 19(Pt 5): 722-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22898952

RESUMO

Carbon contamination of optics is a serious issue in all soft X-ray beamlines because it decreases the quality of experimental data, such as near-edge X-ray absorption fine structure, resonant photoemission and resonant soft X-ray emission spectra in the carbon K-edge region. Here an in situ method involving the use of oxygen activated by zeroth-order synchrotron radiation was used to clean the optics in a vacuum ultraviolet and soft X-ray undulator beamline, BL-13A at the Photon Factory in Tsukuba, Japan. The carbon contamination of the optics was removed by exposing them to oxygen at a pressure of 10(-1)-10(-4) Pa for 17-20 h and simultaneously irradiating them with zeroth-order synchrotron radiation. After the cleaning, the decrease in the photon intensity in the carbon K-edge region reduced to 2-5%. The base pressure of the beamline recovered to 10(-7)-10(-8) Pa in one day without baking. The beamline can be used without additional commissioning.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA