Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Artif. organs ; 48(2): 141-149, fev.2024.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1525065

RESUMO

BACKGROUND: The reactivity of blood with non-endothelial surface is a challenge for long-term Ventricular Assist Devices development, usually made with pure titanium, which despite of being inert, low density and high mechanical resistance it does not avoid the thrombogenic responses. Here we tested a modification on the titanium surface with Laser Induced Periodic Surface Structures followed by Diamond Like Carbon (DLC) coating in different thicknesses to customize the wettability profile by changing the surface energy of the titanium. METHODS: Four different surfaces were proposed: (1) Pure Titanium as Reference Material (RM), (2) Textured as Test Sample (TS), (3) Textured with DLC 0.3µm as (TSA) and (4) Textured with 2.4µm DLC as (TSB). A single implant was positioned in the abdominal aorta of Wistar rats and the effects of hemodynamic interaction were evaluated without anticoagulant drugs. RESULTS: After twelve weeks, the implants were extracted and subjected to qualitative analysis by Scanning Electron Microscopy under low vacuum and X-ray Energy Dispersion. The regions that remained in contact with the wall of the aorta showed encapsulation of the endothelial tissue. TSB implants, although superhydrophilic, have proven that the DLC coating inhibits the adhesion of biological material, prevents abrasive wear and delamination, as observed in the TS and TSA implants. Pseudo- neointimal layers were heterogeneously identified in higher concentration on Test Surfaces.


Assuntos
Teste de Materiais , Coração Auxiliar , Molhabilidade
2.
Artif Organs ; 48(2): 141-149, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38018258

RESUMO

BACKGROUND: The reactivity of blood with non-endothelial surface is a challenge for long-term Ventricular Assist Devices development, usually made with pure titanium, which despite of being inert, low density and high mechanical resistance it does not avoid the thrombogenic responses. Here we tested a modification on the titanium surface with Laser Induced Periodic Surface Structures followed by Diamond Like Carbon (DLC) coating in different thicknesses to customize the wettability profile by changing the surface energy of the titanium. METHODS: Four different surfaces were proposed: (1) Pure Titanium as Reference Material (RM), (2) Textured as Test Sample (TS), (3) Textured with DLC 0.3µm as (TSA) and (4) Textured with 2.4µm DLC as (TSB). A single implant was positioned in the abdominal aorta of Wistar rats and the effects of hemodynamic interaction were evaluated without anticoagulant drugs. RESULTS: After twelve weeks, the implants were extracted and subjected to qualitative analysis by Scanning Electron Microscopy under low vacuum and X-ray Energy Dispersion. The regions that remained in contact with the wall of the aorta showed encapsulation of the endothelial tissue. TSB implants, although superhydrophilic, have proven that the DLC coating inhibits the adhesion of biological material, prevents abrasive wear and delamination, as observed in the TS and TSA implants. Pseudo- neointimal layers were heterogeneously identified in higher concentration on Test Surfaces.


Assuntos
Carbono , Titânio , Ratos , Animais , Propriedades de Superfície , Titânio/química , Ratos Wistar , Teste de Materiais , Carbono/química , Aorta , Materiais Revestidos Biocompatíveis/química
3.
J Adhes Dent ; 25(1): 1-12, 2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36633468

RESUMO

PURPOSE: To evaluate the effect of plasma-enhanced chemical vapor deposition (PECVD) with silicon hydride (SiH4) at different times on HT-zirconia surface characteristics and bonding of composite cement before and after thermocycling. MATERIALS AND METHODS: Blocks of HT zirconia were obtained, polished, sintered and divided into five groups, according to PECVD time (n = 31): Zr-30 (30 s), Zr-60 (60 s), Zr-120 (120 s) and Zr-300 (300 s). The control group (Zr-0) did not receive PECVD. X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), energy dispersive spectroscopy (EDS) in conjunction with field-emission scanning electron microscopy (FE-SEM), x-ray photoelectron spectroscopy (XPS), goniometry, and profilometry tests were used for chemical and topographic characterization. Monobond N silane (Ivoclar Vivadent) was applied to the surface, and a cylinder of composite cement (Variolink N) was made (3 x 3 mm). Half of the specimens of each group were stored for 24 h or subjected to thermocycling (6 x 103 cycles). A shear bond strength (SBS) test was performed. Results were subjected to one-way ANOVA and Tukey's tests (α = 0.05). RESULTS: For experimental groups, XPS showed that formation of Si-O bonds contributed to increased surface free energy (SFE). FE-SEM and EDS showed that the longer the deposition time, the greater the amount of silicon on the surface. Zr-60 and Zr-300 presented higher and lower surface roughnesses, respectively. The silicon penetrated the microstructure, causing higher stress concentrations. The bond strength to composite cement was improved after all PECVD deposition times. CONCLUSION: The PECVD technique with SiH4, associated with chemical treatment with primer based on silane methacrylate, is a solely chemical surface treatment capable of maintaining bonding between composite cement and HT zirconia.


Assuntos
Colagem Dentária , Silício , Silanos , Propriedades de Superfície , Cimentos de Resina , Cimentos Dentários , Zircônio/química , Resistência ao Cisalhamento , Teste de Materiais , Cerâmica/química
4.
Materials (Basel) ; 15(21)2022 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-36363007

RESUMO

Single crystal diamond (SCD) is a promising material to satisfy emerging requirements of high-demand fields, such as microelectronics, beta batteries and wide-spectrum optical communication systems, due to its excellent optical characteristics, elevated breakdown voltage, high hardness and superior thermal conductivity. For such applications, it is essential to study the optically active defects in as-grown diamonds, namely three-dimensional defects (such as stacking faults and dislocations) and the inherent defects arising from the cultivation method. This paper reports the growth of SCD films on a commercial HPHT single-crystal diamond seed substrate using a 2.45 GHz microwave plasma-assisted chemical vapor deposition (MWPACVD) technique by varying the methane (CH4) gas concentration from 6 to 12%, keeping the other parameters constant. The influence of the CH4 concentration on the properties, such as structural quality, morphology and thickness, of the highly oriented SCD films in the crystalline plane (004) was investigated and compared with those on the diamond substrate surface. The SCD film thickness is dependent on the CH4 concentration, and a high growth rate of up to 27 µm/h can be reached. Raman spectroscopy, high-resolution X-ray diffractometry (HRXRD), scanning electron microscopy (SEM), surface profilometry and optical microscopic analyses showed that the produced homoepitaxial SCD films are of good quality with few macroscopic defects.

5.
Nanomaterials (Basel) ; 11(6)2021 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-34070326

RESUMO

Conjugation of photosensitizers (PS) with nanoparticles has been largely used as a strategy to stabilize PS in the biological medium resulting in photosensitizing nanoparticles of enhanced photoactivity. Herein, (Meso-5, 10, 15, 20-tetrakis (3-hydroxyphenyl) phorphyryn (mTHPP) was conjugated with diamond nanoparticles (ND) by covalent bond. Nanoconjugate ND-mTHPP showed suitable stability in aqueous suspension with 58 nm of hydrodynamic diameter and Zeta potential of -23 mV. The antibacterial activity of ND-mTHPP was evaluated against Escherichia coli for different incubation times (0-24 h). The optimal activity was observed after 2 h of incubation and irradiation (660 nm; 51 J/cm2) performed right after the addition of ND-mTHPP (100 µg/mL) to the bacterial suspension. The inhibitory activity was 56% whereas ampicillin at the same conditions provided only 14% of bacterial growth inhibition. SEM images showed agglomerate of ND-mTHPP adsorbed on the bacterial cell wall, suggesting that the antimicrobial activity of ND-mTHPP was afforded by inducing membrane damage. Cytotoxicity against murine embryonic fibroblast cells (MEF) was also evaluated and ND-mTHPP was shown to be noncytotoxic since viability of cells cultured for 24 h in the presence of the nanoconjugate (100 µg/mL) was 78%. Considering the enhanced antibacterial activity and the absence of cytotoxic effect, it is possible to consider the ND-mTHPP nanoconjugate as promising platform for application in antimicrobial photodynamic therapy (aPDT).

6.
Mater Sci Eng C Mater Biol Appl ; 33(2): 641-7, 2013 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25427468

RESUMO

Cartilage serves as a low-friction and wear-resistant articulating surface in diarthrodial joints and is also important during early stages of bone remodeling. Recently, regenerative cartilage research has focused on combinations of cells paired with scaffolds. Superhydrophilic vertically aligned carbon nanotubes (VACNTs) are of particular interest in regenerative medicine. The aim of this study is to evaluate cell expansion of human articular chondrocytes on superhydrophilic VACNTs, as well as their morphology and gene expression. VACNT films were produced using a microwave plasma chamber on Ti substrates and submitted to an O2 plasma treatment to make them superhydrophilic. Human chondrocytes were cultivated on superhydrophilic VACNTs up to five days. Quantitative RT-PCR was performed to measure type I and type II Collagen, Sox9, and Aggrecan mRNA expression levels. The morphology was analyzed by scanning electron microscopy (SEM) and confocal microscopy. SEM images demonstrated that superhydrophilic VACNTs permit cell growth and adhesion of human chondrocytes. The chondrocytes had an elongated morphology with some prolongations. Chondrocytes cultivated on superhydrophilic VACNTs maintain the level expression of Aggrecan, Sox9, and Collagen II determined by qPCR. This study was the first to indicate that superhydrophilic VACNTs may be used as an efficient scaffold for cartilage or bone repair.


Assuntos
Técnicas de Cultura de Células/instrumentação , Condrócitos/citologia , Condrócitos/efeitos dos fármacos , Condrócitos/metabolismo , Nanotubos de Carbono/química , Actinas/química , Actinas/genética , Actinas/metabolismo , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Adesão Celular/fisiologia , Técnicas de Cultura de Células/métodos , Forma Celular/fisiologia , Expressão Gênica , Humanos , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais
7.
Cell Biol Int ; 34(4): 393-8, 2010 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-19947917

RESUMO

Monolayer formation of SaOS-2 (human osteoblast-like cells) was observed on VACNT (vertically aligned multiwalled carbon nanotubes) scaffolds without purification or functionalization. The VACNT were produced by a microwave plasma chemical vapour deposition on titanium surfaces with nickel or iron as catalyst. Cell viability and morphology studies were evaluated by LDH (lactate dehydrogenase) release assay and SEM (scanning electron microscopy), respectively. The non-toxicity and the flat spreading with monolayer formation of the SaOs-2 on VACNT scaffolds surface indicate that they can be used for biomedical applications.


Assuntos
Nanotubos de Carbono , Osteoblastos/citologia , Linhagem Celular , Proliferação de Células , Humanos , Microscopia Eletrônica de Varredura
8.
J Nanosci Nanotechnol ; 9(6): 3891-7, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19504937

RESUMO

A new, low cost, pulsed-DC plasma-enhanced chemical vapor deposition system that uses a bipolar, pulsed power supply was designed and tested to evaluate its capacity to produce quality diamond-like carbon films on the inner surface of steel tubes. The main focus of the study was to attain films with low friction coefficients, low total stress, a high degree of hardness, and very good adherence to the inner surface of long metallic tubes at a reasonable growth rate. In order to enhance the diamond-like carbon coating adhesion to metallic surfaces, four steps were used: (1) argon ion sputtering; (2) plasma nitriding; (3) a thin amorphous silicon interlayer deposition, using silane as the precursor gas; and (4) diamond-like carbon film deposition using methane atmosphere. This paper presents various test results as functions of the methane gas pressure and of the coaxial metal anode diameter, where the pulsed-DC voltage constant is kept constant. The influence of the coaxial metal anode diameter and of the methane gas pressure is also demonstrated. The results obtained showed the possibilities of using these DLC coatings for reduced friction and to harden inner surface of the steel tubes.

9.
J Esthet Restor Dent ; 19(1): 19-28; discussion 29, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17244145

RESUMO

UNLABELLED: During the past decades, scientific developments in cutting instruments have changed the conventional techniques used to remove caries lesions. Ultrasound emerged as an alternative for caries removal since the 1950s. However, the conventional technology for diamond powder aggregation with nickel metallic binders could not withstand ultrasonic power. Around 5 years ago, an alternative approach using chemical vapor deposition (CVD) resulted in synthetic diamond technology. CVD diamond burs are obtained with high adherence of the diamond as a unique stone on the metallic surface with excellent abrading performance. This technology allows for diamond deposition with coalescent granulation in different formats of substrates. When connected to an ultrasonic handpiece, CVD diamond burs become an option for cavity preparation, maximizing preservation of tooth structure. Potential advantages such as reduced noise, minimal damage to the gingival tissue, extended bur durability, improved proximal cavity access, reduced risk of hitting the adjacent tooth resulting from the high inclination angles, and minimal patient's risk of metal contamination. These innovative instruments also potentially eliminate some problems regarding decreased cutting efficiency of conventional diamond burs. CLINICAL SIGNIFICANCE: This clinical report presents the benefits of using CVD diamond burs coupled with an ultrasonic handpiece in the treatment of incipient caries. CVD diamond burs coupled with an ultrasonic device offer a promising alternative for removal of carious lesions when ultraconservative cavity preparations are required. Additionally, this system provides a less-painful technique for caries removal, with minimal noise.


Assuntos
Cárie Dentária/cirurgia , Equipamentos Odontológicos de Alta Rotação , Diamante/uso terapêutico , Preparo Prostodôntico do Dente/instrumentação , Terapia por Ultrassom/métodos , Adulto , Humanos , Masculino , Preparo Prostodôntico do Dente/métodos , Preparo Prostodôntico do Dente/tendências , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA