Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Chirurg ; 91(2): 121-127, 2020 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-32025774

RESUMO

An appropriate perioperative infusion management is pivotal for the perioperative outcome of the patient. Optimization of the perioperative fluid treatment often results in enhanced postoperative outcome, reduced perioperative complications and shortened hospitalization. Hypovolemia as well as hypervolemia can lead to an increased rate of perioperative complications. The main goal is to maintain perioperative euvolemia by goal-directed therapy (GDT), a combination of fluid management and inotropic medication, to optimize perfusion conditions in the perioperative period; however, perioperative fluid management should also include the preoperative and postoperative periods. This encompasses the preoperative administration of carbohydrate-rich drinks up to 2 h before surgery. In the postoperative period, patients should be encouraged to start per os hydration early and excessive i.v. fluid administration should be avoided. Implementation of a comprehensive multimodal, goal-directed fluid management within an enhanced recovery after surgery (ERAS) protocol is efficient but the exact status of indovodual items remains unclear at present.


Assuntos
Hidratação , Assistência Perioperatória , Humanos , Período Perioperatório , Complicações Pós-Operatórias/prevenção & controle , Período Pós-Operatório
2.
Anaesthesist ; 67(10): 780-789, 2018 10.
Artigo em Alemão | MEDLINE | ID: mdl-30203329

RESUMO

Central venous pressure (CVP) is deemed to be an important parameter of anesthesia management in liver surgery. To reduce blood loss during liver resections, a low target value of CVP is often propagated. Although current meta-analyses have shown a connection between low CVP and a reduction in blood loss, the underlying studies show methodological weaknesses and advantages with respect to morbidity and mortality can hardly be proven. The measurement of the CVP itself is associated with numerous limitations and influencing factors and the measures to reduce the CVP have been insufficiently investigated with respect to hepatic hemodynamics. The definition of a generally valid target area for the CVP must be called into question. The primary objective is to maintain adequate oxygen supply and euvolemia. The CVP should be regarded as a mosaic stone of hemodynamic management.


Assuntos
Pressão Venosa Central/fisiologia , Fígado/cirurgia , Perda Sanguínea Cirúrgica/prevenção & controle , Determinação da Pressão Arterial , Hemodinâmica , Hepatectomia/métodos , Humanos , Fígado/irrigação sanguínea , Oxigênio/administração & dosagem , Oxigênio/sangue
3.
Physiol Meas ; 39(2): 024002, 2018 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-29350189

RESUMO

OBJECTIVE: Electrical impedance tomography (EIT) is a non-invasive and radiation-free bedside monitoring technology, primarily used to monitor lung function. First experimental data shows that the descending aorta can be detected at different thoracic heights and might allow the assessment of central hemodynamics, i.e. stroke volume and pulse transit time. APPROACH: First, the feasibility of localizing small non-conductive objects within a saline phantom model was evaluated. Second, this result was utilized for the detection of the aorta by EIT in ten anesthetized pigs with comparison to thoracic computer tomography (CT). Two EIT belts were placed at different thoracic positions and a bolus of hypertonic saline (10 ml, 20%) was administered into the ascending aorta while EIT data were recorded. EIT images were reconstructed using the GREIT model, based on the individual's thoracic contours. The resulting EIT images were analyzed pixel by pixel to identify the aortic pixel, in which the bolus caused the highest transient impedance peak in time. MAIN RESULTS: In the phantom, small objects could be located at each position with a maximal deviation of 0.71 cm. In vivo, no significant differences between the aorta position measured by EIT and the anatomical aorta location were obtained for both measurement planes if the search was restricted to the dorsal thoracic region of interest (ROIs). SIGNIFICANCE: It is possible to detect the descending aorta at different thoracic levels by EIT using an intra-aortic bolus of hypertonic saline. No significant differences in the position of the descending aorta on EIT images compared to CT images were obtained for both EIT belts.


Assuntos
Aorta/diagnóstico por imagem , Tórax/irrigação sanguínea , Tomografia/métodos , Animais , Impedância Elétrica , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Suínos
4.
J Clin Monit Comput ; 32(5): 817-823, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29204771

RESUMO

The aim of this study was to evaluate the accuracy and precision of non-invasive continuous blood pressure measurement by applanation tonometry (AT) in awake or anaesthetised cardiological intensive care patients. Patients suffering from highly impaired left ventricular function atrial fibrillation or severe aortic valve stenosis were included into the study. Arterial blood pressure was recorded by applanation tonometry (T-Line 400, Tensys Medical®, USA) and an arterial line in awake or anaesthetised patients. Discrepancies in mean (MAP), systolic (SAP), and diastolic (DAP) arterial pressure between the two methods were assessed as bias, limits of agreement and percentage error respectively. In 31 patients a total of 27,900 measurements were analyzed. The concordance correlation coefficient was 0.23, 0.45 and 0.06 for MAP, SAP and DAP, respectively. For all patients bias for MAPAT compared to MAPAL was 14.96 mmHg (SAPAT 4.51 mmHg; DAPAT 19.12 mmHg) with limits of agreement for MAPAT of 46.25 and - 16.33 mm Hg (SAPAT 48.00 and - 38.98 mmHg; DAPAT 50.12 and - 11.89 mmHg). Percentage error for MAPAT was 56.8% (42.7% for SAPAT; 75.2% for DAPAT). We conclude that the AT method is not reliable in ICU patients with severe cardiac comorbidities.


Assuntos
Determinação da Pressão Arterial/métodos , Monitorização Hemodinâmica/métodos , Manometria/métodos , Idoso , Estenose da Valva Aórtica/fisiopatologia , Pressão Arterial/fisiologia , Fibrilação Atrial/fisiopatologia , Determinação da Pressão Arterial/estatística & dados numéricos , Unidades de Cuidados Coronarianos , Cuidados Críticos , Feminino , Monitorização Hemodinâmica/estatística & dados numéricos , Humanos , Masculino , Manometria/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia , Análise de Ondaletas
5.
Br J Anaesth ; 118(1): 68-76, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28039243

RESUMO

BACKGROUND: Functional imaging by thoracic electrical impedance tomography (EIT) is a non-invasive approach to continuously assess central stroke volume variation (SVV) for guiding fluid therapy. The early available data were from healthy lungs without injury-related changes in thoracic impedance as a potentially influencing factor. The aim of this study was to evaluate SVV measured by EIT (SVVEIT) against SVV from pulse contour analysis (SVVPC) in an experimental animal model of acute lung injury at different lung volumes. METHODS: We conducted a randomized controlled trial in 30 anaesthetized domestic pigs. SVVEIT was calculated automatically analysing heart-lung interactions in a set of pixels representing the aorta. Each initial analysis was performed automatically and unsupervised using predefined frequency domain algorithms that had not previously been used in the study population. After baseline measurements in normal lung conditions, lung injury was induced either by repeated broncho-alveolar lavage (n=15) or by intravenous administration of oleic acid (n=15) and SVVEIT was remeasured. RESULTS: The protocol was completed in 28 animals. A total of 123 pairs of SVV measurements were acquired. Correlation coefficients (r) between SVVEIT and SVVPC were 0.77 in healthy lungs, 0.84 after broncho-alveolar lavage, and 0.48 after lung injury from oleic acid. CONCLUSIONS: EIT provides automated calculation of a dynamic preload index of fluid responsiveness (SVVEIT) that is non-invasively derived from a central haemodynamic signal. However, alterations in thoracic impedance induced by lung injury influence this method.


Assuntos
Lesão Pulmonar Aguda/fisiopatologia , Impedância Elétrica , Hidratação , Volume Sistólico , Tomografia/métodos , Animais , Respiração com Pressão Positiva , Suínos
6.
Br J Anaesth ; 117(2): 228-35, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27440635

RESUMO

BACKGROUND: Lung-protective ventilation is claimed to be beneficial not only in critically ill patients, but also in pulmonary healthy patients undergoing general anaesthesia. We report the use of electrical impedance tomography for assessing regional changes in ventilation, during both spontaneous breathing and mechanical ventilation, in patients undergoing robot-assisted radical prostatectomy. METHODS: We performed electrical impedance tomography measurements in 39 patients before induction of anaesthesia in the sitting (M1) and supine position (M2), after the start of mechanical ventilation (M3), during capnoperitoneum and Trendelenburg positioning (M4), and finally, in the supine position after release of capnoperitoneum (M5). To quantify regional changes in lung ventilation, we calculated the centre of ventilation and 'silent spaces' in the ventral and dorsal lung regions that did not show major impedance changes. RESULTS: Compared with the awake supine position [2.3% (2.3)], anaesthesia and mechanical ventilation induced a significant increase in silent spaces in the dorsal dependent lung [9.2% (6.3); P<0.05]. Capnoperitoneum and the Trendelenburg position led to a significant increase in such spaces [11.5% (8.9)]. Silent space in the ventral lung remained constant throughout anaesthesia. CONCLUSION: Electrical impedance tomography was able to identify and quantify on a breath-by-breath basis circumscribed areas, so-called silent spaces, within healthy lungs that received little or no ventilation during general anaesthesia, capnoperitoneum, and different body positions. As these silent spaces are suggestive of atelectasis on the one hand and overdistension on the other, they might become useful to guide individualized protective ventilation strategies to mitigate the side-effects of anaesthesia and surgery on the lungs.


Assuntos
Posicionamento do Paciente , Ventilação Pulmonar , Tomografia/métodos , Resistência das Vias Respiratórias , Anestesia Geral , Cuidados Críticos , Impedância Elétrica , Decúbito Inclinado com Rebaixamento da Cabeça , Humanos , Masculino , Peritônio/diagnóstico por imagem , Decúbito Ventral , Prostatectomia , Atelectasia Pulmonar/diagnóstico por imagem , Respiração Artificial , Procedimentos Cirúrgicos Robóticos , Decúbito Dorsal
7.
Br J Anaesth ; 116(6): 790-6, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27095239

RESUMO

BACKGROUND: The aim of this study was to evaluate the validity of non-invasive continuous BP measurement by applanation tonometry in morbidly obese patients undergoing bariatric surgery. METHODS: Arterial blood pressure (AP) was recorded intraoperatively both by applanation tonometry (AT) (T-Line 200pro, Tensys Medical(®), USA) and an arterial line (AL) after radial cannulation in obese patients undergoing bariatric surgery. Discrepancies between the two methods were assessed as bias, limits of agreement and percentage error. Mean, systolic, and diastolic arterial pressures were assessed (MAP, SAP, DAP respectively). Trending ability was assessed by concordance based on four-quadrant plotting. RESULTS: Mean (sd) BMI of the 28 patients was 49.4 (9.7 kg m(-2)). A total of 201 907 time points were available for analysis. Bias for MAPAT compared with MAPAL was +3.97 mm Hg (SAPAT +3.45 mm Hg; DAPAT +3.66 mm Hg) with limits of agreement for MAPAT of -14.47 and +22.41 mm Hg (SAPAT -22.0 and +28.9 mm Hg; DAPAT -15.7 and +23.1 mm Hg). Percentage error for MAPAT was 23.5% (23.4% for SAPAT; 30.5% for DAPAT). Trending ability for MAP, SAP, and DAP revealed a concordance of 0.74, 0.72, and 0.71, respectively. CONCLUSIONS: Continuous BP assessment by applanation tonometry is feasible in morbidly obese patients undergoing bariatric surgery. However, despite a low mean difference, 95% limits of agreement and trending ability indicate that the technology needs to be improved further, before being recommended for routine use in this group of patients.


Assuntos
Pressão Arterial , Cirurgia Bariátrica/métodos , Determinação da Pressão Arterial/métodos , Manometria/métodos , Monitorização Intraoperatória/métodos , Obesidade Mórbida/fisiopatologia , Obesidade Mórbida/cirurgia , Adulto , Idoso , Índice de Massa Corporal , Cuidados Críticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
8.
Anaesthesist ; 64(7): 494-505, 2015 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-26081011

RESUMO

Goal-directed hemodynamic therapy is becoming increasingly more interesting for anesthesiologists and intensive care physicians. Meta-analyses of studies evaluating perioperative therapy algorithms demonstrated a reduction of postoperative morbidity compared to the previous clinical practices. In this review article the basic concepts of goal-directed hemodynamic therapy and the principles of previously employed therapy algorithms are described and discussed. Furthermore, the questions of how these therapy strategies can be transferred into daily clinical practice and whether these therapeutic approaches might even bear risks for patients are elucidated.


Assuntos
Hidratação/métodos , Hemodinâmica/fisiologia , Algoritmos , Débito Cardíaco , Objetivos , Humanos , Assistência Perioperatória , Complicações Pós-Operatórias/prevenção & controle , Resultado do Tratamento
9.
Br J Anaesth ; 111(5): 736-42, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23811425

RESUMO

BACKGROUND: Predicting the response of cardiac output to volume administration remains an ongoing clinical challenge. The objective of our study was to compare the ability to predict volume responsiveness of various functional measures of cardiac preload. These included pulse pressure variation (PPV), stroke volume variation (SVV), and the recently launched automated respiratory systolic variation test (RSVT) in patients after major surgery. METHODS: In this prospective study, 24 mechanically ventilated patients after major surgery were enrolled. Three consecutive volume loading steps consisting of 300 ml 6% hydroxyethylstarch 130/0.4 were performed and cardiac index (CI) was assessed by transpulmonary thermodilution. Volume responsiveness was considered as positive if CI increased by >10%. RESULTS: In total 72 volume loading steps were analysed, of which 41 showed a positive volume response. Receiver operating characteristic (ROC) curve analysis revealed an area under the curve (AUC) of 0.70 for PPV, 0.72 for SVV and 0.77 for RSVT. Areas under the curves of all variables did not differ significantly from each other (P>0.05). Suggested cut-off values were 9.9% for SVV, 10.1% for PPV, and 19.7° for RSVT as calculated by the Youden Index. CONCLUSION: In predicting fluid responsiveness the new automated RSVT appears to be as accurate as established dynamic indicators of preload PPV and SVV in patients after major surgery. The automated RSVT is clinically easy to use and may be useful in guiding fluid therapy in ventilated patients.


Assuntos
Pressão Sanguínea/fisiologia , Hidratação/métodos , Cuidados Pós-Operatórios/métodos , Mecânica Respiratória/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Resistência das Vias Respiratórias , Algoritmos , Anestesia Geral , Pressão Arterial/fisiologia , Automação , Débito Cardíaco/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Período Pós-Operatório , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Volume Sistólico/fisiologia , Termodiluição , Adulto Jovem
10.
Br J Anaesth ; 110(6): 957-65, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23462192

RESUMO

BACKGROUND: It is unclear what factors affect the uptake of sevoflurane administered through the membrane oxygenator during cardiopulmonary bypass (CPB) and whether this can be monitored via the oxygenator exhaust gas. METHODS: Stable delivery of sevoflurane was administered to 30 elective cardiac surgery patients at 1.8 vol% (inspiratory) via the anaesthetic circuit and ventilator. During CPB, sevoflurane was administered in the oxygenator fresh gas supply (Compactflo Evolution™; Sorin Group, Milano, Italy). Sevoflurane plasma concentration (SPC) was measured using gas chromatography. Changes were correlated with bispectral index (BIS), patient temperature, haematocrit, plasma albumin concentration, oxygenator fresh gas flow, and the sevoflurane concentration in the oxygenator exhaust at predefined time points. RESULTS: The mean SPC pre-bypass was 54.9 µg ml(-1) [95% confidence interval (CI): 50.6-59.1]. SPC decreased to 43.2 µg ml(-1) (95% CI: 40.3-46.1; P<0.001) after initiation of CPB, and was lower still during rewarming and weaning from bypass, 39.4 µg ml(-1) (95% CI: 36.6-42.3; P<0.001). BIS did not exceed a value of 55. SPCs were higher during hypothermia (P<0.001) and with an increase in oxygenator fresh gas flow (P=0.015), and lower with haemodilution (P=0.027). No correlation was found between SPC and the concentration of sevoflurane in the oxygenator exhaust gas (r=-0.04; 95% CI: -0.18 to 0.09; P=0.53). CONCLUSIONS: The uptake of sevoflurane delivered via the membrane oxygenator during CPB seems to be affected by hypothermia, haemodilution, and changes in the oxygenator fresh gas supply flow. Measuring the concentration of sevoflurane in the exhaust from the oxygenator is not useful for monitoring sevoflurane administration during bypass.


Assuntos
Anestésicos Inalatórios/sangue , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Éteres Metílicos/sangue , Oxigenadores de Membrana , Idoso , Idoso de 80 Anos ou mais , Eletroencefalografia , Feminino , Humanos , Masculino , Éteres Metílicos/administração & dosagem , Pessoa de Meia-Idade , Estudos Prospectivos , Sevoflurano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA