1.
Small ; 20(38): e2311546, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38766975

RESUMO

Bacterial adhesion to stainless steel, an alloy commonly used in shared settings, numerous medical devices, and food and beverage sectors, can give rise to serious infections, ultimately leading to morbidity, mortality, and significant healthcare expenses. In this study, Cu-coated nanotextured stainless steel (nSS) fabrication have been demonstrated using electrochemical technique and its potential as an antibiotic-free biocidal surface against Gram-positive and negative bacteria. As nanotexture and Cu combine for dual methods of killing, this material should not contribute to drug-resistant bacteria as antibiotic use does. This approach involves applying a Cu coating on nanotextured stainless steel, resulting in an antibacterial activity within 30 min. Comprehensive characterization of the surface revealing that the Cu coating consists of metallic Cu and oxidized states (Cu2+ and Cu+), has been performed by this study. Cu-coated nSS induces a remarkable reduction of 97% in Gram-negative Escherichia coli and 99% Gram-positive Staphylococcus epidermidis bacteria. This material has potential to be used to create effective, scalable, and sustainable solutions to prevent bacterial infections caused by surface contamination without contributing to antibiotic resistance.


Assuntos
Antibacterianos , Cobre , Escherichia coli , Aço Inoxidável , Aço Inoxidável/química , Cobre/química , Cobre/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Escherichia coli/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Staphylococcus epidermidis/efeitos dos fármacos , Propriedades de Superfície , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Aderência Bacteriana/efeitos dos fármacos
2.
PLoS One ; 16(10): e0257777, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34637444

RESUMO

Nitrogen-functionalization is an effective means of improving the catalytic performances of nanozymes. In the present work, plasma-assisted nitrogen modification of nanocolumnar Ni GLAD films was performed using an ammonia plasma, resulting in an improvement in the peroxidase-like catalytic performance of the porous, nanostructured Ni films. The plasma-treated nanozymes were characterized by TEM, SEM, XRD, and XPS, revealing a nitrogen-rich surface composition. Increased surface wettability was observed after ammonia plasma treatment, and the resulting nitrogen-functionalized Ni GLAD films presented dramatically enhanced peroxidase-like catalytic activity. The optimal time for plasma treatment was determined to be 120 s; when used to catalyze the oxidation of the colorimetric substrate TMB in the presence of H2O2, Ni films subjected to 120 s of plasma treatment yielded a much higher maximum reaction velocity (3.7⊆10-8 M/s vs. 2.3⊆10-8 M/s) and lower Michaelis-Menten coefficient (0.17 mM vs. 0.23 mM) than pristine Ni films with the same morphology. Additionally, we demonstrate the application of the nanozyme in a gravity-driven, continuous catalytic reaction device. Such a controllable plasma treatment strategy may open a new door toward surface-functionalized nanozymes with improved catalytic performance and potential applications in flow-driven point-of-care devices.


Assuntos
Peróxido de Hidrogênio/química , Nanoestruturas/química , Nitrogênio/química , Peroxidase/química , Amônia/química , Antioxidantes/química , Biocatálise , Catálise , Colorimetria , Corantes/química , Níquel/química , Oxirredução/efeitos dos fármacos , Oxigênio/química , Espectroscopia Fotoeletrônica , Propriedades de Superfície
3.
ACS Omega ; 5(16): 9123-9130, 2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-32363264

RESUMO

We present a nanozyme-based biosensor fabricated from nanostructured Ni films deposited onto a silicon wafer by glancing angle deposition (GLAD) for enzyme-free colorimetric monitoring of uric acid (UA), a biomarker for gout, high blood pressure, heart disease, and kidney disease. The helically structured Ni GLAD nanozymes exhibit excellent peroxidase-like activity to accelerate the oxidation reaction of colorless 3,3',5,5'-tetramethylbenzidine (TMB) to a blue product, oxidized TMB (oxTMB), mediated by H2O2. In the presence of UA, oxTMB is reduced, decreasing the optical absorbance by an amount determined by the concentration of UA in the solution. The nanozyme not only mimics peroxidase but also possesses the notable qualities of reusability, simple operation, and reliability, making it environment-friendly and suitable for on-demand analysis. We optimized essential working parameters (pH, TMB concentration, and H2O2 concentration) to maximize the initial color change of the TMB solution. The catalytic activity of this nanozyme was compared with conventional nanofilms using the Michaelis-Menten theory. Based on this, enzyme-free biosensors were developed for colorimetric detection of UA, providing a wide detection range and a limit of detection (3.3 µM) suitable for measurements of UA concentration in sweat. Furthermore, interference from glucose and urea was studied so as to explore the potential of the biosensor for use in the clinical diagnosis of UA biomarkers.