Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Am J Otolaryngol ; 45(3): 104226, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38295450

RESUMO

PURPOSE: Endoscopic ear surgery has become a popular operative approach to treat middle ear diseases. Surgeons use either 0° or 30° endoscopes worldwide. The main aim of the work was to compare the properties of these two types of endoscopes. MATERIAL AND METHODS: Since this type of evaluation is hard to perform in vivo during the actual surgery, we designed 3D printed temporal bone models with different levels of complexity. The evaluation of endoscopes was based on image analysis or visibility of anatomical structures. RESULTS: The results show that a 30° endoscope offers a view of lateral walls from 4 mm distance, contrary to a 0° endoscope which cannot see lateral walls from this distance at all. On the other hand, visible area of the anterior wall is up to 40 % larger using 0° endoscope, compared to 30° endoscope. Angled endoscope distorts the picture and leads to the deterioration of the image. At commonly used distances above 5 mm from middle ear structures, resolution and image distortion is comparable between both endoscopes. CONCLUSIONS: Our results do not offer a definitive opinion on which endoscope is better for ear surgery. Both types of endoscopes have advantages and disadvantages, and the choice depends on the surgeon's personal preference and on the type of planned procedure.


Assuntos
Orelha Média , Endoscópios , Endoscopia , Modelos Anatômicos , Procedimentos Cirúrgicos Otológicos , Impressão Tridimensional , Humanos , Endoscopia/métodos , Procedimentos Cirúrgicos Otológicos/métodos , Procedimentos Cirúrgicos Otológicos/instrumentação , Orelha Média/cirurgia , Osso Temporal/cirurgia , Desenho de Equipamento
2.
J Neurol Sci ; 446: 120588, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36827809

RESUMO

In post-stroke spasticity (PSS), effective treatment with botulinum neurotoxin (BoNT) is associated with transient decrease in activation of the ipsilesional superior parietal lobule (SPL) and intraparietal sulcus (IPS). We hypothesized that this would be reflected in changes in resting-state functional connectivity (rsFC) of the SPL/IPS. Our aim was therefore to assess rsFC of the ipsilesional SPL/IPS in chronic stroke patients with hemiparesis both with and without PSS and to explore the relationship between SPL/IPS rsFC and PSS severity. To this end, fourteen chronic stroke patients with upper limb weakness and PSS (the PSS group) and 8 patients with comparable weakness but no PSS (the control group) underwent clinical evaluation and 3 fMRI examinations, at baseline (W0) and 4 and 11 weeks after BoNT (W4 and W11, respectively). Seed-based rsFC of the atlas-based SPL and IPS was evaluated using a group×time interaction analysis and a correlation analysis with PSS severity (modified Ashworth scale), integrity of the ipsilesional somatosensory afferent pathway (evoked potential N20 latency), and age. In the PSS group, transient improvement in PSS was associated with increase in rsFC between the ipsilesional IPS and the contralesional SPL at W4. The interhemispheric connectivity was negatively correlated with PSS severity at baseline and with PSS improvement at W4. We propose adaptation of the internal forward model as the putative underlying mechanism and discuss its possible association with increased limb use, diminished spastic dystonia, or improved motor performance, as well as its potential contribution to the clinical effects of BoNT.


Assuntos
Toxinas Botulínicas Tipo A , Fármacos Neuromusculares , Acidente Vascular Cerebral , Humanos , Toxinas Botulínicas Tipo A/uso terapêutico , Espasticidade Muscular , Fármacos Neuromusculares/uso terapêutico , Acidente Vascular Cerebral/complicações , Lobo Parietal , Imageamento por Ressonância Magnética
3.
Otol Neurotol ; 43(2): e205-e211, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34855680

RESUMO

HYPOTHESIS: Higher light intensity settings do not yield improved image quality in endoscopic ear surgery. BACKGROUND: Light intensity is a parameter with major impact on the quality of digital images. For ear surgery, light produces heat associated with a thermal risk to ear structures and the light source setting should be accordingly optimized. METHODS: Several series of still images were acquired during live middle ear surgery, using cadaveric and plastic temporal bone models and with three-dimensional printed models. Images obtained under varying light intensities were compared with the image acquired at maximum intensity of a light emitting diode light source. We analyzed digital image brightness and noise using quantitative methods. RESULTS: Our measurements revealed significantly decreased image brightness with light intensities set below 20% with an increase in noise at light intensities lower than 30%. CONCLUSION: The optimal light source setting corresponded to 30% intensity in our experimental set-up. Special attention should be given to those cases where faster image quality degradation is expected (dark or bloody scenes or larger cavities). The results were strongly dependent on the equipment used. The methods described in this study can serve as a general guide for determining the optimal light source setting in any specific set-up.


Assuntos
Procedimentos Cirúrgicos Otológicos , Orelha Média/cirurgia , Endoscopia , Humanos , Osso Temporal
4.
Front Neurosci ; 15: 703620, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34658759

RESUMO

The "Different Hearing" program (DHP) is an educational activity aimed at stimulating musical creativity of children and adults by group composing in the classroom, alternative to the mainstream model of music education in Czechia. Composing in the classroom in the DHP context does not use traditional musical instruments or notation, instead, the participants use their bodies, sounds originating from common objects as well as environmental sounds as the "elements" for music composition by the participants' team, with the teacher initiating and then participating and coordinating the creative process, which ends with writing down a graphical score and then performing the composition in front of an audience. The DHP methodology works with a wide definition of musical composition. We hypothesized that the DHP short-term (2 days) intense workshop would induce changes in subjective appreciation of different classes of music and sound (including typical samples of music composed in the DHP course), as well as plastic changes of the brain systems engaged in creative thinking and music perception, in their response to diverse auditory stimuli. In our study, 22 healthy university students participated in the workshop over 2 days and underwent fMRI examinations before and after the workshop, meanwhile 24 students were also scanned twice as a control group. During fMRI, each subject was listening to musical and non-musical sound samples, indicating their esthetic impression with a button press after each sample. As a result, participants' favorable feelings toward non-musical sound samples were significantly increased only in the active group. fMRI data analyzed using ANOVA with post hoc ROI analysis showed significant group-by-time interaction (opposing trends in the two groups) in the bilateral posterior cingulate cortex/precuneus, which are functional hubs of the default mode network (DMN) and in parts of the executive, motor, and auditory networks. The findings suggest that DHP training modified the behavioral and brain response to diverse sound samples, differentially changing the engagement of functional networks known to be related to creative thinking, namely, increasing DMN activation and decreasing activation of the executive network.

5.
Ultrasonics ; 115: 106461, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34000664

RESUMO

In many in vitro experiments studying ultrasound bioeffects the sonicated samples are placed to far field with intention of exposing them to as uniform ultrasound field as possible. The main aim of this work is to assess whether the sonicated samples really experience what they are believed to. Also we would like to suggest basic rules for construction of sonication vessels. We used 3.5 MHz and 7 MHz ultrasound transducers for measurements. We measured ultrasound field inside and behind common culture plates and special 3D printed plates placed to last axial maximum in water sonication tank with use of a needle hydrophone. Our results show that even though the sonication vessels with sonicated samples are placed into far field, the sonicated samples are actually exposed to some kind of a near field pattern which develops due to the interaction between ultrasound and well of culture plate. The variability of local acoustic intensity can reach up to several hundreds of percent. Our results are also supported by theoretical calculation and software for simulation of ultrasound fields. Even though the sonicated samples may have actually been exposed to some kind of near field pattern in many past studies, the whole phenomenon of creation of near field pattern can be controlled to some extent for future studies. Thus, we suggest that the sonication vessel should always be designed for particular ultrasound transducer.

6.
Sci Rep ; 11(1): 8322, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33859210

RESUMO

In cervical dystonia, functional MRI (fMRI) evidence indicates changes in several resting state networks, which revert in part following the botulinum neurotoxin A (BoNT) therapy. Recently, the involvement of the cerebellum in dystonia has gained attention. The aim of our study was to compare connectivity between cerebellar subdivisions and the rest of the brain before and after BoNT treatment. Seventeen patients with cervical dystonia indicated for treatment with BoNT were enrolled (14 female, aged 50.2 ± 8.5 years, range 38-63 years). Clinical and fMRI examinations were carried out before and 4 weeks after BoNT injection. Clinical severity was evaluated using TWSTRS. Functional MRI data were acquired on a 1.5 T scanner during 8 min rest. Seed-based functional connectivity analysis was performed using data extracted from atlas-defined cerebellar areas in both datasets. Clinical scores demonstrated satisfactory BoNT effect. After treatment, connectivity decreased between the vermis lobule VIIIa and the left dorsal mesial frontal cortex. Positive correlations between the connectivity differences and the clinical improvement were detected for the right lobule VI, right crus II, vermis VIIIb and the right lobule IX. Our data provide evidence for modulation of cerebello-cortical connectivity resulting from successful treatment by botulinum neurotoxin.


Assuntos
Toxinas Botulínicas Tipo A/administração & dosagem , Cerebelo/fisiopatologia , Cognição/fisiologia , Descanso/fisiologia , Torcicolo/tratamento farmacológico , Torcicolo/fisiopatologia , Adulto , Córtex Cerebral/fisiopatologia , Feminino , Humanos , Injeções Intralesionais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Torcicolo/diagnóstico por imagem , Torcicolo/psicologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA