Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Digit Imaging ; 36(5): 1987-1994, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37349619

RESUMO

The purpose of this short report is to illustrate the implementation of a RIS function for balancing radiological activities and workloads between two different teams of radiologists from the same Diagnostic Department during emergency nights and holiday shifts. One group is from the main hospital, Arcispedale S.Maria Nuova di Reggio Emilia, and the other group belongs to the five minor hospitals in the district of Reggio Emilia.The implementation of a dedicated balancing function in the RIS system successfully allows the balancing of the radiological activity between two or more teams of different radiologists, while preserving the care continuity of care and the involved workers' experience and confidence in reporting.


Assuntos
Serviço Hospitalar de Emergência , Carga de Trabalho , Humanos , Diagnóstico por Imagem
3.
Phys Med Biol ; 65(11): 11NT02, 2020 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-32311679

RESUMO

This work aims to characterize the novel DRX Plus 3543C detector in terms of detective quantum efficiency (DQE) using both a mobile x-ray system called Carestream DRX Revolution Nano and a traditional x-ray system (Carestream DRX Evolution). We used the commercial system DRX Revolution Nano, equipped with a new x-ray source based on CNT technology and field emission (FE) as the electron emitter (cathode). An innovative aspect of this device is its intrinsic selection of the focal spot size. We tested the system using three IEC-specified beam qualities (RQA3, 5 and 7) in terms of modulation transfer function (MTF), normalized noise power spectra (NNPS) and DQE as defined in the IEC 62220-1-1:2015. We compared the results obtained using DRX Revolution Nano and DRX Evolution with correlation and with Bland-Altman plots to study their agreement. RQA3 MTF is slightly lower than the RQA5 and 7 curves between 0.5 and 2.5 cycles mm-1. We measured MTF values of about 0.6 at 1 lp mm-1 and about 0.28 lp mm-1 at 2 lp mm-1. The NNPS curves show a decreasing trend with the energy regarding the DRX Revolution Nano. On the other hand, the DRX Evolution NNPS curve at RQA3 is greater than the one at RQA5, but the one at RQA5 is less than the one at RQA7. The DQE(0) ranged between about 0.82 (DRX Evolution at RQA3) and 0.54 (DRX Evolution at RQA7). As expected, the squared Pearson's correlation coefficients between the two x-ray tubes were always in an optimal agreement, and Bland-Altman plots confirmed a substantial equivalence between the two physical characterizations of the wireless detector. In conclusion, we can show that the dynamic focal selection of the system equipped with CNT does not play a substantial role in image quality compared to a traditional system in terms of physical characterisation of the detector in our measurement conditions.


Assuntos
Nanotubos de Carbono/química , Dosímetros de Radiação/normas , Radiografia/métodos , Radiografia/instrumentação , Tecnologia sem Fio/instrumentação , Raios X
4.
EJNMMI Phys ; 7(1): 17, 2020 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-32180029

RESUMO

PURPOSE: Currently, no consistent guidelines for CT scans used within PET/CT examinations are available. This systematic review provides an up-to-date overview of studies to answer the following questions: What are the specific CT protocols used in PET/CT? What are the possible purposes of requiring a CT study within a PET/CT scan? Is the CT protocol obtained from a dosimetric optimisation study? MATERIALS AND METHOD: PubMed/MEDLINE, Cochrane Library, Embase and Scopus were systematically searched for relevant studies in accordance with the PRISMA statement. The literature search was conducted from January 2007 until June 2019. Data derived from studies were standardized in order to reduce possible biases, and they were divided into clinically homogeneous subgroups (adult, child or phantom). Subsequently, we divided the CT protocol intents into 3 types (anatomic localization only, attenuation correction only and diagnostic purpose). A narrative approach was used to summarise datasets and to investigate their heterogeneity (due to medical prescription methodology) and their combination in multiseries CT protocols. When weighted computed tomography dose index (CTDIw) was available, we calculated the volumetric computed tomography dose index (CTDIvol) using the pitch value to make the results uniform. Eventually, the correlation between protocol intents and CTDIvol values was obtained using a Kruskal-Wallis one-way ANOVA statistical test. RESULT: Starting from a total of 1440 retrieved records, twenty-four studies were eligible for inclusion in addition to two large multicentric works that we used to compare the results. We analyzed 87 CT protocols. There was a considerable range of variation in the acquisition parameters: tube current-time product revealed to have the most variable range, which was 10-300 mAs for adults and 10-80 mAs for paediatric patients. Seventy percent of datasets presented scans acquired with tube current modulation, 9% used fixed tube current and in 21% of them, this information was not available. Dependence between mean CTDIvol values and protocol intent was statistically significant (p = 0.002). As expected, in diagnostic protocols, there was a statistically significant difference between CTDIvol values of with and without contrast acquisitions (11.68 mGy vs 7.99 mGy, p = 0.009). In 13 out of 87 studies, the optimisation aim was not reported; in 2 papers, a clinical protocol was used; and in 11 works, a dose optimisation protocol was applied. CONCLUSIONS: According to this review, the dose optimisation in PET/CT exams depends heavily on the correct implementation of the CT protocol. In addition to this, considering the latest technology advances (i.e. iterative algorithms development), we suggest a periodic quality control audit to stay updated on new clinical utility modalities and to achieve a shared standardisation of clinical protocols. In conclusion, this study pointed out the necessity to better identify the specific CT protocol use within PET/CT scans, taking into account the continuous development of new technologies.

5.
Biomed Phys Eng Express ; 6(2): 025008, 2020 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-33438634

RESUMO

The goal of this paper was the comparison of radiation dose and imaging quality before and after the Clarity IQ technology installation in a Philips AlluraXper FD20/20 angiography system using a Channelized Hotelling Observer model (CHO). The core characteristics of the Allura Clarity IQ technology are its real-time noise reduction algorithms (NRT) combined with state-of-the-art hardware; this technology allows to implement acquisition protocols able to significantly reduce patient entrance dose. To measure the system performances in terms of image quality we used a contrast detail phantom in a clinical scatter condition. A Leeds TO10 phantom has been imaged between two 10 cm thick homogeneous solid water slabs. Fluoroscopy images were acquired using a cerebral protocol at 3 dose levels (low, medium and high) with a field- of view (FOV) of 31 cm. Cineangiography images were acquired using a cerebral protocol at 2 fps. Thus, 4 acquisitions were obtained for the conventional technology and 4 acquisitions were taken after the Clarity IQ upgrade, for a total of 8 different image sets. A validated 40 Gabor channels CHO with an internal noise model compared the image sets. Human observers' studies were carried out to tune the internal noise parameter. We showed that the CHO did not detect any significant difference between any of the image sets acquired using the two technologies. Consequently, this x-ray imaging technology provides a non-inferior image quality with an average patient dose reduction of 57% and 28% respectively in cineangiography and fluoroscopy. The Clarity IQ installation has certainly allowed a considerable improvement in patient and staff safety, while maintaining the same image quality.


Assuntos
Algoritmos , Angiografia/normas , Processamento de Imagem Assistida por Computador/normas , Variações Dependentes do Observador , Imagens de Fantasmas , Controle de Qualidade , Tomografia Computadorizada por Raios X/métodos , Cineangiografia/métodos , Fluoroscopia/métodos , Humanos , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA