Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cancers (Basel) ; 16(3)2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38339322

RESUMO

Esophageal carcinoma (EC) is a prominent contributor to cancer-related mortality since it lacks discernible features in its first phases. Multiple studies have shown that narrow-band imaging (NBI) has superior accuracy, sensitivity, and specificity in detecting EC compared to white light imaging (WLI). Thus, this study innovatively employs a color space linked to décor to transform WLIs into NBIs, offering a novel approach to enhance the detection capabilities of EC in its early stages. In this study a total of 3415 WLI along with the corresponding 3415 simulated NBI images were used for analysis combined with the YOLOv5 algorithm to train the WLI images and the NBI images individually showcasing the adaptability of advanced object detection techniques in the context of medical image analysis. The evaluation of the model's performance was based on the produced confusion matrix and five key metrics: precision, recall, specificity, accuracy, and F1-score of the trained model. The model underwent training to accurately identify three specific manifestations of EC, namely dysplasia, squamous cell carcinoma (SCC), and polyps demonstrates a nuanced and targeted analysis, addressing diverse aspects of EC pathology for a more comprehensive understanding. The NBI model effectively enhanced both its recall and accuracy rates in detecting dysplasia cancer, a pre-cancerous stage that might improve the overall five-year survival rate. Conversely, the SCC category decreased its accuracy and recall rate, although the NBI and WLI models performed similarly in recognizing the polyp. The NBI model demonstrated an accuracy of 0.60, 0.81, and 0.66 in the dysplasia, SCC, and polyp categories, respectively. Additionally, it attained a recall rate of 0.40, 0.73, and 0.76 in the same categories. The WLI model demonstrated an accuracy of 0.56, 0.99, and 0.65 in the dysplasia, SCC, and polyp categories, respectively. Additionally, it obtained a recall rate of 0.39, 0.86, and 0.78 in the same categories, respectively. The limited number of training photos is the reason for the suboptimal performance of the NBI model which can be improved by increasing the dataset.

2.
Sci Rep ; 13(1): 20502, 2023 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-37993660

RESUMO

The clinical signs and symptoms of esophageal cancer (EC) are often not discernible until the intermediate or advanced phases. The detection of EC in advanced stages significantly decreases the survival rate to below 20%. This study conducts a comparative analysis of the efficacy of several imaging techniques, including white light image (WLI), narrowband imaging (NBI), cycle-consistent adversarial network simulated narrowband image (CNBI), and hyperspectral imaging simulated narrowband image (HNBI), in the early detection of esophageal cancer (EC). In conjunction with Kaohsiung Armed Forces General Hospital, a dataset consisting of 1000 EC pictures was used, including 500 images captured using WLI and 500 images captured using NBI. The CycleGAN model was used to generate the CNBI dataset. Additionally, a novel method for HSI imaging was created with the objective of generating HNBI pictures. The evaluation of the efficacy of these four picture types in early detection of EC was conducted using three indicators: CIEDE2000, entropy, and the structural similarity index measure (SSIM). Results of the CIEDE2000, entropy, and SSIM analyses suggest that using CycleGAN to generate CNBI images and HSI model for creating HNBI images is superior in detecting early esophageal cancer compared to the use of conventional WLI and NBI techniques.


Assuntos
Neoplasias Esofágicas , Imageamento Hiperespectral , Humanos , Detecção Precoce de Câncer , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/radioterapia , Imagem de Banda Estreita , Luz
3.
Biomed Opt Express ; 14(8): 4383-4405, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37799695

RESUMO

One of the leading causes of cancer deaths is esophageal cancer (EC) because identifying it in early stage is challenging. Computer-aided diagnosis (CAD) could detect the early stages of EC have been developed in recent years. Therefore, in this study, complete meta-analysis of selected studies that only uses hyperspectral imaging to detect EC is evaluated in terms of their diagnostic test accuracy (DTA). Eight studies are chosen based on the Quadas-2 tool results for systematic DTA analysis, and each of the methods developed in these studies is classified based on the nationality of the data, artificial intelligence, the type of image, the type of cancer detected, and the year of publishing. Deeks' funnel plot, forest plot, and accuracy charts were made. The methods studied in these articles show the automatic diagnosis of EC has a high accuracy, but external validation, which is a prerequisite for real-time clinical applications, is lacking.

4.
Cancers (Basel) ; 15(19)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37835409

RESUMO

Video capsule endoscopy (VCE) is increasingly used to decrease discomfort among patients owing to its small size. However, VCE has a major drawback of not having narrow band imaging (NBI) functionality. The current VCE has the traditional white light imaging (WLI) only, which has poor performance in the computer-aided detection (CAD) of different types of cancer compared to NBI. Specific cancers, such as esophageal cancer (EC), do not exhibit any early biomarkers, making their early detection difficult. In most cases, the symptoms are unnoticeable, and EC is diagnosed only in later stages, making its 5-year survival rate below 20% on average. NBI filters provide particular wavelengths that increase the contrast and enhance certain features of the mucosa, thereby enabling early identification of EC. However, VCE does not have a slot for NBI functionality because its size cannot be increased. Hence, NBI image conversion from WLI can presently only be achieved in post-processing. In this study, a complete arithmetic assessment of the decorrelated color space was conducted to generate NBI images from WLI images for VCE of the esophagus. Three parameters, structural similarity index metric (SSIM), entropy, and peak-signal-to-noise ratio (PSNR), were used to assess the simulated NBI images. Results show the good performance of the NBI image reproduction method with SSIM, entropy difference, and PSNR values of 93.215%, 4.360, and 28.064 dB, respectively.

5.
Diagnostics (Basel) ; 13(14)2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37510118

RESUMO

Hydroxychloroquine, also known as quinine, is primarily utilized to manage various autoimmune diseases, such as systemic lupus erythematosus, rheumatoid arthritis, and Sjogren's syndrome. However, this drug has side effects, including diarrhea, blurred vision, headache, skin itching, poor appetite, and gastrointestinal discomfort. Blurred vision is caused by irreversible retinal damages and can only be mitigated by reducing hydroxychloroquine dosage or discontinuing the drug under a physician's supervision. In this study, color fundus images were utilized to identify differences in lesions caused by hydroxychloroquine. A total of 176 color fundus images were captured from a cohort of 91 participants, comprising 25 patients diagnosed with hydroxychloroquine retinopathy and 66 individuals without any retinopathy. The mean age of the participants was 75.67 ± 7.76. Following the selection of a specific region of interest within each image, hyperspectral conversion technology was employed to obtain the spectrum of the sampled image. Spectral analysis was then conducted to discern differences between normal and hydroxychloroquine-induced lesions that are imperceptible to the human eye on the color fundus images. We implemented a deep learning model to detect lesions, leveraging four artificial neural networks (ResNet50, Inception_v3, GoogLeNet, and EfficientNet). The overall accuracy of ResNet50 reached 93% for the original images (ORIs) and 96% for the hyperspectral images (HSIs). The overall accuracy of Inception_v3 was 87% for ORIs and 91% for HSI, and that of GoogLeNet was 88% for ORIs and 91% for HSIs. Finally, EfficientNet achieved an overall accuracy of 94% for ORIs and 97% for HSIs.

6.
J Pers Med ; 13(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37373927

RESUMO

The severity of diabetic retinopathy (DR) is directly correlated to changes in both the oxygen utilization rate of retinal tissue as well as the blood oxygen saturation of both arteries and veins. Therefore, the current stage of DR in a patient can be identified by analyzing the oxygen content in blood vessels through fundus images. This enables medical professionals to make accurate and prompt judgments regarding the patient's condition. However, in order to use this method to implement supplementary medical treatment, blood vessels under fundus images need to be determined first, and arteries and veins then need to be differentiated from one another. Therefore, the entire study was split into three sections. After first removing the background from the fundus images using image processing, the blood vessels in the images were then separated from the background. Second, the method of hyperspectral imaging (HSI) was utilized in order to construct the spectral data. The HSI algorithm was utilized in order to perform analysis and simulations on the overall reflection spectrum of the retinal image. Thirdly, principal component analysis (PCA) was performed in order to both simplify the data and acquire the major principal components score plot for retinopathy in arteries and veins at all stages. In the final step, arteries and veins in the original fundus images were separated using the principal components score plots for each stage. As retinopathy progresses, the difference in reflectance between the arteries and veins gradually decreases. This results in a more difficult differentiation of PCA results in later stages, along with decreased precision and sensitivity. As a consequence of this, the precision and sensitivity of the HSI method in DR patients who are in the normal stage and those who are in the proliferative DR (PDR) stage are the highest and lowest, respectively. On the other hand, the indicator values are comparable between the background DR (BDR) and pre-proliferative DR (PPDR) stages due to the fact that both stages exhibit comparable clinical-pathological severity characteristics. The results indicate that the sensitivity values of arteries are 82.4%, 77.5%, 78.1%, and 72.9% in the normal, BDR, PPDR, and PDR, while for veins, these values are 88.5%, 85.4%, 81.4%, and 75.1% in the normal, BDR, PPDR, and PDR, respectively.

7.
Sci Rep ; 13(1): 8378, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37225785

RESUMO

In this study, we present the growth of monolayer MoS2 (molybdenum disulfide) film. Mo (molybdenum) film was formed on a sapphire substrate through e-beam evaporation, and triangular MoS2 film was grown by direct sulfurization. First, the growth of MoS2 was observed under an optical microscope. The number of MoS2 layers was analyzed by Raman spectrum, atomic force microscope (AFM), and photoluminescence spectroscopy (PL) measurement. Different sapphire substrate regions have different growth conditions of MoS2. The growth of MoS2 is optimized by controlling the amount and location of precursors, adjusting the appropriate growing temperature and time, and establishing proper ventilation. Experimental results show the successful growth of a large-area single-layer MoS2 on a sapphire substrate through direct sulfurization under a suitable environment. The thickness of the MoS2 film determined by AFM measurement is about 0.73 nm. The peak difference between the Raman measurement shift of 386 and 405 cm-1 is 19.1 cm-1, and the peak of PL measurement is about 677 nm, which is converted into energy of 1.83 eV, which is the size of the direct energy gap of the MoS2 thin film. The results verify the distribution of the number of grown layers. Based on the observation of the optical microscope (OM) images, MoS2 continuously grows from a single layer of discretely distributed triangular single-crystal grains into a single-layer large-area MoS2 film. This work provides a reference for growing MoS2 in a large area. We expect to apply this structure to various heterojunctions, sensors, solar cells, and thin-film transistors.

8.
Sensors (Basel) ; 23(4)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36850623

RESUMO

In this study, a snapshot-based hyperspectral imaging (HSI) algorithm that converts RGB images to HSI images is designed using the Raspberry Pi environment. A Windows-based Python application is also developed to control the Raspberry Pi camera and processor. The mean gray values (MGVs) of two distinct regions of interest (ROIs) are selected from three samples of 100 NTD Taiwanese currency notes and compared with three samples of counterfeit 100 NTD notes. Results suggest that the currency notes can be easily differentiated on the basis of MGV values within shorter wavelengths, between 400 nm and 500 nm. However, the MGV values are similar in longer wavelengths. Moreover, if an ROI has a security feature, then the classification method is considerably more efficient. The key features of the module include portability, lower cost, a lack of moving parts, and no processing of images required.

9.
J Clin Med ; 12(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36769781

RESUMO

Many studies have recently used several deep learning methods for detecting skin cancer. However, hyperspectral imaging (HSI) is a noninvasive optics system that can obtain wavelength information on the location of skin cancer lesions and requires further investigation. Hyperspectral technology can capture hundreds of narrow bands of the electromagnetic spectrum both within and outside the visible wavelength range as well as bands that enhance the distinction of image features. The dataset from the ISIC library was used in this study to detect and classify skin cancer on the basis of basal cell carcinoma (BCC), squamous cell carcinoma (SCC), and seborrheic keratosis (SK). The dataset was divided into training and test sets, and you only look once (YOLO) version 5 was applied to train the model. The model performance was judged according to the generated confusion matrix and five indicating parameters, including precision, recall, specificity, accuracy, and the F1-score of the trained model. Two models, namely, hyperspectral narrowband image (HSI-NBI) and RGB classification, were built and then compared in this study to understand the performance of HSI with the RGB model. Experimental results showed that the HSI model can learn the SCC feature better than the original RGB image because the feature is more prominent or the model is not captured in other categories. The recall rate of the RGB and HSI models were 0.722 to 0.794, respectively, thereby indicating an overall increase of 7.5% when using the HSI model.

10.
Sci Rep ; 12(1): 18475, 2022 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-36323727

RESUMO

One of the challenges in differentiating a duplicate hologram from an original one is reflectivity. A slight change in lighting condition will completely change the reflection pattern exhibited by a hologram, and consequently, a standardized duplicate hologram detector has not yet been created. In this study, a portable and low-cost snapshot hyperspectral imaging (HSI) algorithm-based housing module for differentiating between original and duplicate holograms was proposed. The module consisted of a Raspberry Pi 4 processor, a Raspberry Pi camera, a display, and a light-emitting diode lighting system with a dimmer. A visible HSI algorithm that could convert an RGB image captured by the Raspberry Pi camera into a hyperspectral image was established. A specific region of interest was selected from the spectral image and mean gray value (MGV) and reflectivity were measured. Results suggested that shorter wavelengths are the most suitable for differentiating holograms when using MGV as the parameter for classification, while longer wavelengths are the most suitable when using reflectivity. The key features of this design include low cost, simplicity, lack of moving parts, and no requirement for an additional decoding key.


Assuntos
Algoritmos , Imageamento Hiperespectral , Iluminação
11.
Sensors (Basel) ; 22(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36236407

RESUMO

Forgery and tampering continue to provide unnecessary economic burdens. Although new anti-forgery and counterfeiting technologies arise, they inadvertently lead to the sophistication of forgery techniques over time, to a point where detection is no longer viable without technological aid. Among the various optical techniques, one of the recently used techniques to detect counterfeit products is HSI, which captures a range of electromagnetic data. To aid in the further exploration and eventual application of the technique, this study categorizes and summarizes existing related studies on hyperspectral imaging and creates a mini meta-analysis of this stream of literature. The literature review has been classified based on the product HSI has used in counterfeit documents, photos, holograms, artwork, and currency detection.


Assuntos
Imageamento Hiperespectral
12.
Appl Opt ; 61(20): 6046-6056, 2022 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-36255841

RESUMO

Surface defect detection is a crucial step in ensuring the quality of lenses. One method to check for surface defects is to use an optical system integrated with an industrial camera to magnify and highlight the position of a defect on the surface of a lens. Therefore, automatic optical inspection systems are applied to detect micro-defects. In this study, we propose an automatic inspection platform based on a deep neural network for automatically imaging and examining the surface of a lens. High-resolution images of 2448×2048 pixels are acquired using a hybrid lighting system. A convolutional neural network integrated with a trainable Gabor filter is used as a machine vision algorithm to perform image classification and defect segmentation tasks. The experimental results show that the proposed method effectively performed with noise in the background, achieving a segmentation accuracy of 98%.


Assuntos
Lentes , Redes Neurais de Computação , Algoritmos , Diagnóstico por Imagem , Aprendizado de Máquina
13.
Cancers (Basel) ; 14(17)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36077827

RESUMO

In this study, the combination of hyperspectral imaging (HSI) technology and band selection was coupled with color reproduction. The white-light images (WLIs) were simulated as narrow-band endoscopic images (NBIs). As a result, the blood vessel features in the endoscopic image became more noticeable, and the prediction performance was improved. In addition, a single-shot multi-box detector model for predicting the stage and location of esophageal cancer was developed to evaluate the results. A total of 1780 esophageal cancer images, including 845 WLIs and 935 NBIs, were used in this study. The images were divided into three stages based on the pathological features of esophageal cancer: normal, dysplasia, and squamous cell carcinoma. The results showed that the mean average precision (mAP) reached 80% in WLIs, 85% in NBIs, and 84% in HSI images. This study's results showed that HSI has more spectral features than white-light imagery, and it improves accuracy by about 5% and matches the results of NBI predictions.

14.
J Pers Med ; 12(8)2022 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-35893299

RESUMO

Early detection of esophageal cancer has always been difficult, thereby reducing the overall five-year survival rate of patients. In this study, semantic segmentation was used to predict and label esophageal cancer in its early stages. U-Net was used as the basic artificial neural network along with Resnet to extract feature maps that will classify and predict the location of esophageal cancer. A total of 75 white-light images (WLI) and 90 narrow-band images (NBI) were used. These images were classified into three categories: normal, dysplasia, and squamous cell carcinoma. After labeling, the data were divided into a training set, verification set, and test set. The training set was approved by the encoder-decoder model to train the prediction model. Research results show that the average time of 111 ms is used to predict each image in the test set, and the evaluation method is calculated in pixel units. Sensitivity is measured based on the severity of the cancer. In addition, NBI has higher accuracy of 84.724% when compared with the 82.377% accuracy rate of WLI, thereby making it a suitable method to detect esophageal cancer using the algorithm developed in this study.

15.
Int J Mol Sci ; 23(9)2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35563136

RESUMO

In this study, n-type MoS2 monolayer flakes are grown through chemical vapor deposition (CVD), and a p-type Cu2O thin film is grown via electrochemical deposition. The crystal structure of the grown MoS2 flakes is analyzed through transmission electron microscopy. The monolayer structure of the MoS2 flakes is verified with Raman spectroscopy, multiphoton excitation microscopy, atomic force microscopy, and photoluminescence (PL) measurements. After the preliminary processing of the grown MoS2 flakes, the sample is then transferred onto a Cu2O thin film to complete a p-n heterogeneous structure. Data are confirmed via scanning electron microscopy, SHG, and Raman mapping measurements. The luminous energy gap between the two materials is examined through PL measurements. Results reveal that the thickness of the single-layer MoS2 film is 0.7 nm. PL mapping shows a micro signal generated at the 627 nm wavelength, which belongs to the B2 excitons of MoS2 and tends to increase gradually when it approaches 670 nm. Finally, the biosensor is used to detect lung cancer cell types in hydroplegia significantly reducing the current busy procedures and longer waiting time for detection. The results suggest that the fabricated sensor is highly sensitive to the change in the photocurrent with the number of each cell, the linear regression of the three cell types is as high as 99%. By measuring the slope of the photocurrent, we can identify the type of cells and the number of cells.


Assuntos
Técnicas Biossensoriais , Neoplasias Pulmonares , Técnicas Biossensoriais/métodos , Humanos , Neoplasias Pulmonares/diagnóstico , Microscopia Eletrônica de Transmissão , Molibdênio/química , Análise Espectral Raman
16.
Nanomaterials (Basel) ; 12(1)2021 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-35010085

RESUMO

Molybdenum disulfide (MoS2) was grown on a laser-processed periodic-hole sapphire substrate through chemical vapor deposition. The main purpose was to investigate the mechanism of MoS2 growth in substrate with a periodic structure. By controlling the amount and position of the precursor, adjusting the growth temperature and time, and setting the flow rate of argon gas, MoS2 grew in the region of the periodic holes. A series of various growth layer analyses of MoS2 were then confirmed by Raman spectroscopy, photoluminescence spectroscopy, and atomic force microscopy. Finally, the growth mechanism was studied by transmission electron microscopy (TEM). The experimental results show that in the appropriate environment, MoS2 can be successfully grown on substrate with periodic holes, and the number of growth layers can be determined through measurements. By observing the growth mechanism, composition analysis, and selected area electron diffraction diagram by TEM, we comprehensively understand the growth phenomenon. The results of this research can serve as a reference for the large-scale periodic growth of MoS2. The production of periodic structures by laser drilling is advantageous, as it is relatively simpler than other methods.

17.
BMC Genomics ; 13 Suppl 7: S4, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23282187

RESUMO

BACKGROUND: The opportunistic enterobacterium, Morganella morganii, which can cause bacteraemia, is the ninth most prevalent cause of clinical infections in patients at Changhua Christian Hospital, Taiwan. The KT strain of M. morganii was isolated during postoperative care of a cancer patient with a gallbladder stone who developed sepsis caused by bacteraemia. M. morganii is sometimes encountered in nosocomial settings and has been causally linked to catheter-associated bacteriuria, complex infections of the urinary and/or hepatobiliary tracts, wound infection, and septicaemia. M. morganii infection is associated with a high mortality rate, although most patients respond well to appropriate antibiotic therapy. To obtain insights into the genome biology of M. morganii and the mechanisms underlying its pathogenicity, we used Illumina technology to sequence the genome of the KT strain and compared its sequence with the genome sequences of related bacteria. RESULTS: The 3,826,919-bp sequence contained in 58 contigs has a GC content of 51.15% and includes 3,565 protein-coding sequences, 72 tRNA genes, and 10 rRNA genes. The pathogenicity-related genes encode determinants of drug resistance, fimbrial adhesins, an IgA protease, haemolysins, ureases, and insecticidal and apoptotic toxins as well as proteins found in flagellae, the iron acquisition system, a type-3 secretion system (T3SS), and several two-component systems. Comparison with 14 genome sequences from other members of Enterobacteriaceae revealed different degrees of similarity to several systems found in M. morganii. The most striking similarities were found in the IS4 family of transposases, insecticidal toxins, T3SS components, and proteins required for ethanolamine use (eut operon) and cobalamin (vitamin B12) biosynthesis. The eut operon and the gene cluster for cobalamin biosynthesis are not present in the other Proteeae genomes analysed. Moreover, organisation of the 19 genes of the eut operon differs from that found in the other non-Proteeae enterobacterial genomes. CONCLUSIONS: This is the first genome sequence of M. morganii, which is a clinically relevant pathogen. Comparative genome analysis revealed several pathogenicity-related genes and novel genes not found in the genomes of other members of Proteeae. Thus, the genome sequence of M. morganii provides important information concerning virulence and determinants of fitness in this pathogen.


Assuntos
Genoma Bacteriano , Morganella morganii/genética , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Mapeamento de Sequências Contíguas , Farmacorresistência Bacteriana , Infecções por Bactérias Gram-Negativas/microbiologia , Humanos , Morganella morganii/isolamento & purificação , Morganella morganii/patogenicidade , Proteus mirabilis/genética , Análise de Sequência de DNA
18.
BMC Genomics ; 12 Suppl 3: S23, 2011 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-22369086

RESUMO

BACKGROUND: Cardiovascular disease is the chief cause of death in Taiwan and many countries, of which myocardial infarction (MI) is the most serious condition. Hyperlipidemia appears to be a significant cause of myocardial infarction, because it causes atherosclerosis directly. In recent years, copy number variation (CNV) has been analyzed in genomewide association studies of complex diseases. In this study, CNV was analyzed in blood samples and SNP arrays from 31 myocardial infarction patients with hyperlipidemia. RESULTS: We identified seven CNV regions that were associated significantly with hyperlipidemia and myocardial infarction in our patients through multistage analysis (P<0.001), at 1p21.3, 1q31.2 (CDC73), 1q42.2 (DISC1), 3p21.31 (CDCP1), 10q11.21 (RET) 12p12.3 (PIK3C2G) and 16q23.3 (CDH13), respectively. In particular, the CNV region at 10q11.21 was examined by quantitative real-time PCR, the results of which were consistent with microarray findings. CONCLUSIONS: Our preliminary results constitute an alternative method of evaluating the relationship between CNV regions and cardiovascular disease. These susceptibility CNV regions may be used as biomarkers for early-stage diagnosis of hyperlipidemia and myocardial infarction, rendering them valuable for further research and discussion.


Assuntos
Variações do Número de Cópias de DNA , Hiperlipidemias/complicações , Hiperlipidemias/genética , Infarto do Miocárdio/complicações , Infarto do Miocárdio/genética , Adulto , Idoso , Colesterol/sangue , Feminino , Estudo de Associação Genômica Ampla , Humanos , Lipoproteínas LDL/sangue , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA