Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Curr Neurovasc Res ; 15(2): 111-119, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29766804

RESUMO

BACKGROUND: Cyclophilin A plays a pathogenic role in the development and progression of atherosclerosis, which can be assessed by measuring carotid intima-media thickness. The primary aim of this study was to examine the interaction between plasma Cyclophilin A level and carotid intima-media thickness in patients with acute ischemic stroke. METHOD: Plasma concentration of Cyclophilin A was measured on admission in 66 consecutive patients who had been hospitalized for acute cerebral stroke and in 52 case-control subjects without a history of acute stroke. Subjects in both groups also underwent ultrasound B-mode imaging to measure the mean and maximum intima-media thickness of the carotid artery. Inflammatory biomarkers including high-sensitivity C-reactive protein and fibrinogen were also assessed. RESULTS: We found that the plasma concentration of Cyclophilin A was significantly higher in patients with acute ischemic stroke (p = 0.042). Increased Cyclophilin A was also correlated with carotid intima-media thickness in the patient group (p < 0.001). Among the risk factors for cerebral stroke examined in this study, only hypertension was significantly associated with plasma Cyclophilin A level. CONCLUSION: Increased plasma Cyclophilin A levels might be involved in the pathophysiology of acute ischemic stroke and Cyclophilin A might serve as a biomarker in risk assessment of acute stroke patients.


Assuntos
Biomarcadores/sangue , Isquemia Encefálica/complicações , Ciclofilina A/sangue , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/etiologia , Adulto , Idoso , Análise de Variância , Proteína C-Reativa/metabolismo , Artéria Carótida Primitiva/diagnóstico por imagem , Espessura Intima-Media Carotídea , Feminino , Humanos , Hipertensão/etiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Acidente Vascular Cerebral/complicações
2.
Medicine (Baltimore) ; 95(31): e4501, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27495100

RESUMO

Exogenous administration of coenzyme Q10 (CoQ10) has been shown in experimental models to have a protective effect against ischemia-reperfusion injury. However, it is unclear whether follow-up plasma CoQ10 concentration is prognostic of left ventricular (LV) performance after primary balloon angioplasty in patients with acute ST segment elevation myocardial infarction (STEMI).We prospectively recruited 55 patients with STEMI who were treated with primary coronary balloon angioplasty. Plasma CoQ10 concentrations were measured before primary angioplasty (baseline) and 3 days, 7 days, and 1 month after STEMI using high-performance liquid chromatography. Echocardiography was performed at baseline and at 6-month follow-up. The control group comprised 54 healthy age- and sex-matched volunteers.Serial circulating CoQ10 concentrations significantly decreased with time in the STEMI group. The LV ejection fraction at 6-month follow-up positively correlated with the 1-month plasma CoQ10 tertile. Higher plasma CoQ10 concentrations at 1 month were associated with favorable LV remodeling and systolic function 6 months after STEMI. Multiple linear regression analysis showed that changes in CoQ10 concentrations at 1-month follow-up were predictive of LV systolic function 6 months after STEMI. Changes in CoQ10 concentrations correlated negatively with baseline oxidized low-density lipoprotein and fibrinogen concentrations and correlated positively with leukocyte mitochondrial copy number at baseline.Patients with STEMI who had higher plasma CoQ10 concentrations 1 month after primary angioplasty had better LV performance at 6-month follow-up. In addition, higher plasma CoQ10 concentration was associated with lower grade inflammatory and oxidative stress status. Therefore, plasma CoQ10 concentration may serve as a novel prognostic biomarker of LV systolic function after revascularization therapy for acute myocardial infarction.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Volume Sistólico , Ubiquinona/análogos & derivados , Função Ventricular Esquerda , Biomarcadores/sangue , Estudos de Casos e Controles , Variações do Número de Cópias de DNA , DNA Mitocondrial , Feminino , Fibrinogênio/análise , Seguimentos , Humanos , Leucócitos/metabolismo , Lipoproteínas LDL/sangue , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Ubiquinona/sangue , Remodelação Ventricular
3.
Medicine (Baltimore) ; 94(39): e1683, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26426668

RESUMO

Cyclophilin A (CyPA), an oxidative stress-induced factor, was found to play an important role in the aneurysm formation. Our working hypothesis was that the plasma level of CyPA in ruptured intracranial aneurysm could predict the neurological outcome. From 2011 to 2013, a total of 36 patients with ruptured saccular intracranial aneurysm were recruited in our study. Before coil embolization, we draw blood samples at the orifice of a culprit aneurysm and in the remote peripheral vein for measurements of the CyPA levels. We utilized the modified Rankin scale 30 days after aneurysm rupture as the outcome measure. Generalized linear models were used to estimate the adjusted odds ratios of the poor neurological outcome given the presence of high plasma level of CyPA. The aneurysmal and venous CyPA levels were significantly associated with the initial clinical severity (P = 0.004 and 0.03, respectively) and 30-day outcome (P = 0.01 and 0.02, respectively). The aneurysmal CyPA levels modestly correlated with age and high Fisher grade (ρ = 0.39 and 0.41; P = 0.02 and 0.01, respectively). The aneurysmal CyPA levels strongly correlated with the venous counterpart (ρ = 0.89; P < 0.001). Patients with high levels of aneurysmal CyPA were 15.66 times (95% CI, 1.48-166.24; P = 0.02) more likely to have worse neurological outcome than those with the low levels after adjustment of the age, gender, and the documented confounding factors. High plasma level of CyPA is a significant prognostic biomarker for poor neurological outcome in patients with ruptured intracranial aneurysm.


Assuntos
Aneurisma Roto/sangue , Aneurisma Roto/terapia , Ciclofilina A/sangue , Aneurisma Intracraniano/sangue , Aneurisma Intracraniano/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico , Biomarcadores/sangue , Embolização Terapêutica , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Razão de Chances , Prognóstico , Resultado do Tratamento
4.
PLoS One ; 10(7): e0132115, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26176774

RESUMO

BACKGROUND: Interleukin-6 (IL-6), a proinflammatory cytokine, was found to surge in the cerebral spinal fluid after aneurysmal subarachnoid hemorrhage (SAH). We hypothesized that the plasma level of IL-6 could be an independent biomarker in predicting clinical outcome of patients with ruptured intracranial aneurysm. METHODS: We prospectively included 53 consecutive patients treated with platinum coil embolization of the ruptured intracranial aneurysm. Plasma IL-6 levels were measured in the blood samples at the orifices of the aneurysms and from peripheral veins. The outcome measure was the modified Rankin Scale one month after SAH. Multiple logistic regression analyses were used to evaluate the associations between the plasma IL-6 levels and the neurological outcome. RESULTS: Significant risk factors for the poor outcome were old age, low Glasgow Coma Scale (GCS) on day 0, high Fisher grades, and high aneurysmal and venous IL-6 levels in univariate analyses. Aneurysmal IL-6 levels showed modest to moderate correlations with GCS on day 0, vasospasm grade and Fisher grade. A strong correlation was found between the aneurysmal and the corresponding venous IL-6 levels (ρ = 0.721; P<0.001). In the multiple logistic regression models, the poor 30-day mRS was significantly associated with high aneurysmal IL-6 level (OR, 17.97; 95% CI, 1.51-214.33; P = 0.022) and marginally associated with high venous IL-6 level (OR, 12.71; 95% CI, 0.90-180.35; P = 0.022) after adjusting for dichotomized age, GCS on day 0, and vasospasm and Fisher grades. CONCLUSIONS: The plasma level of IL-6 is an independent prognostic biomarker that could be used to aid in the identification of patients at high-risk of poor neurological outcome after rupture of the intracranial aneurysm.


Assuntos
Aneurisma Roto/diagnóstico , Interleucina-6/sangue , Aneurisma Intracraniano/diagnóstico , Adulto , Idoso , Aneurisma Roto/patologia , Aneurisma Roto/terapia , Área Sob a Curva , Biomarcadores/sangue , Embolização Terapêutica , Feminino , Escala de Coma de Glasgow , Humanos , Interleucina-6/líquido cefalorraquidiano , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/terapia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Prognóstico , Estudos Prospectivos , Curva ROC , Fatores de Risco , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/patologia
5.
Biomarkers ; 18(8): 716-20, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24164594

RESUMO

Vascular cytokines, total nitrite, and cyclophilin-A (CyP-A) may be related to the pathogenesis of untreated hypertension. Forty males with normotensive and untreated essential hypertension were recruited in this cytokines survey. Body mass index (BMI), hyperlipidemia, and plasma CyP-A were increased in the hypertensive group (p < 0.05). However, only BMI (p = 0.022) and plasma CyP-A (p = 0.020) were found to be significant contributors to hypertension by multiple regression analysis. CyP-A was also positively correlated with systolic blood pressure (p = 0.029) and diastolic blood pressure (p = 0.047). These findings indicated that plasma CyP-A is a critical molecular biomarker in the early pathogenesis of essential hypertension.


Assuntos
Biomarcadores/sangue , Ciclofilina A/sangue , Hipertensão/sangue , Pressão Sanguínea , Índice de Massa Corporal , Estudos de Casos e Controles , Citocinas/sangue , Humanos , Hiperlipidemias/sangue , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA