Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Artif Organs ; 27(1): 15-22, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36795227

RESUMO

Although adverse events related to extracorporeal membrane oxygenation have been reported, epidemiological data on life-threatening events are insufficient to study the causes of such adverse events. Data from the Japan Council for Quality Health Care database were retrospectively analyzed. The adverse events extracted from this national database included events associated with extracorporeal membrane oxygenation reported between January 2010 and December 2021. We identified 178 adverse events related to extracorporeal membrane oxygenation. At least 41 (23%) and 47 (26%) accidents resulted in death and residual disability, respectively. The most common adverse events were cannula malposition (28%), decannulation (19%), and bleeding (15%). Among patients with cannula malposition, 38% did not undergo fluoroscopy-guided or ultrasound-guided cannulation, 54% required surgical treatment, and 18% required trans-arterial embolization. In this epidemiological study in Japan, 23% of the adverse events related to extracorporeal membrane oxygenation had fatal outcomes. Our findings suggest that a training system for cannulation techniques may be needed, and hospitals offering extracorporeal membrane oxygenation should perform emergency surgeries.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Estudos Retrospectivos , Japão/epidemiologia , Cateterismo/efeitos adversos , Cateterismo/métodos , Cânula
2.
PLoS One ; 17(8): e0273173, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35976965

RESUMO

BACKGROUND: Increased and decreased diaphragm thickness during mechanical ventilation is associated with poor outcomes. Some types of patient-ventilator asynchrony theoretically cause myotrauma of the diaphragm. However, the effects of double cycling on structural changes in the diaphragm have not been previously evaluated. Hence, this study aimed to investigate the relationship between double cycling during the early phase of mechanical ventilation and changes in diaphragm thickness, and the involvement of inspiratory effort in the occurrence of double cycling. METHODS: We evaluated adult patients receiving invasive mechanical ventilation for more than 48 h. The end-expiratory diaphragm thickness (Tdiee) was assessed via ultrasonography on days 1, 2, 3, 5 and 7 after the initiation of mechanical ventilation. Then, the maximum rate of change from day 1 (ΔTdiee%) was evaluated. Concurrently, we recorded esophageal pressure and airway pressure on days 1, 2 and 3 for 1 h during spontaneous breathing. Then, the waveforms were retrospectively analyzed to calculate the incidence of double cycling (double cycling index) and inspiratory esophageal pressure swing (ΔPes). Finally, the correlation between double cycling index as well as ΔPes and ΔTdiee% was investigated using linear regression models. RESULTS: In total, 19 patients with a median age of 69 (interquartile range: 65-78) years were enrolled in this study, and all received pressure assist-control ventilation. The Tdiee increased by more than 10% from baseline in nine patients, decreased by more than 10% in nine and remained unchanged in one. The double cycling indexes on days 1, 2 and 3 were 2.2%, 1.3% and 4.5%, respectively. There was a linear correlation between the double cycling index on day 3 and ΔTdiee% (R2 = 0.446, p = 0.002). The double cycling index was correlated with the ΔPes on days 2 (R2 = 0.319, p = 0.004) and 3 (R2 = 0.635, p < 0.001). CONCLUSIONS: Double cycling on the third day of mechanical ventilation was associated with strong inspiratory efforts and, possibly, changes in diaphragm thickness.


Assuntos
Diafragma , Respiração Artificial , Adulto , Idoso , Diafragma/diagnóstico por imagem , Humanos , Respiração com Pressão Positiva , Estudos Retrospectivos , Ventiladores Mecânicos
3.
J Med Invest ; 67(3.4): 332-337, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33148911

RESUMO

Background : Since diaphragm passivity induces oxidative stress that leads to rapid atrophy of diaphragm, we investigated the effect of controlled ventilation on diaphragm thickness during assist-control ventilation (ACV). Methods : Previously, we measured end-expiratory diaphragm thickness (Tdiee) of patients mechanically ventilated for more than 48 hours on days 1, 3, 5 and 7 after the start of ventilation. We retrospectively investigated the proportion of controlled ventilation during the initial 48-hour ACV (CV48%). Patients were classified according to CV48% : Low group, less than 25% ; High group, higher than 25%. Results : Of 56 patients under pressure-control ACV, Tdiee increased more than 10% in 6 patients (11%), unchanged in 8 patients (14%) and decreased more than 10% in 42 patients (75%). During the first week of ventilation, Tdiee decreased in both groups : Low (difference, -7.4% ; 95% confidence interval [CI], -10.1% to -4.6% ; p < 0.001) and High group (difference, -5.2% ; 95% CI, -8.5% to -2.0% ; p = 0.049). Maximum Tdiee variation from baseline did not differ between Low (-15.8% ; interquartile range [IQR], -22.3 to -1.5) and High group (-16.7% ; IQR, -22.6 to -11.1, p = 0.676). Conclusions : During ACV, maximum variation in Tdiee was not associated with proportion of controlled ventilation higher than 25%. J. Med. Invest. 67 : 332-337, August, 2020.


Assuntos
Diafragma/patologia , Respiração Artificial/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Humanos , Pessoa de Meia-Idade , Respiração com Pressão Positiva , Estudos Retrospectivos , Adulto Jovem
4.
Cureus ; 12(7): e9303, 2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32832300

RESUMO

Introduction Sleep-disordered breathing (SDB) is common after stroke. Although the standard treatment of SDB is continuous positive airway pressure (CPAP) ventilation, the patient's intolerance and discomfort result in low adherence rates. Alternatively, high-flow nasal cannula (HFNC) may be useful as it reduces upper airway collapse with low level of positive pressure and well tolerability. The aim of this study was to investigate whether HFNC therapy reduces SDB and improves sleep quality with higher compliance rate. Methods We included acute stroke patients with SDB for the assessment of apnea-hypopnea index (AHI) >5/h using WatchPAT 200 (Itamar Medical Ltd, Caesarea, Israel). Patients who met inclusion criteria received HFNC therapy (40 L/min) with monitoring by WatchPAT. AHI, oxygen desaturation index (ODI), sleep efficiency, and rapid eye movement (REM) sleep were compared in patients with and without HFNC therapy. We also evaluated the patient's comfort of HFNC therapy (discomfort or not). Results Among 17 patients assessed for AHI, 12 received HFNC therapy. HFNC therapy was not adhered in two patients due to intolerance. Eight patients remained for final analysis. There were no differences in SDB and sleep quality with and without HFNC therapy as follows: HFNC therapy vs control; AHI 24.9 ± 20.1 vs 21.3 ± 15.0/h (p = 0.63), ODI 16.2 ± 16.5 vs 12.9 ± 12.3/h (p = 0.54), sleep efficiency 80.4 ± 12.9 vs 87.1 ± 6.2 (p = 0.28), percentage of REM sleep 19.4% ± 9.6% vs 27.6% ± 8.9% (p = 0.07). Two patients (17%) complained of discomfort among eight patients. Conclusion HFNC therapy did not improve SDB and sleep quality. Nonadherence and discomfort were observed in HFNC therapy. We need a large trial to confirm this result.

5.
Respir Care ; 59(1): 70-4, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23737548

RESUMO

BACKGROUND: High-flow nasal cannula (HFNC) creates positive oropharyngeal airway pressure and improves oxygenation. It remains unclear, however, whether HFNC improves thoraco-abdominal synchrony in patients with mild to moderate respiratory failure. Using respiratory inductive plethysmography, we investigated the effects of HFNC on thoraco-abdominal synchrony. METHODS: We studied 40 adult subjects requiring oxygen therapy in the ICU. Low-flow oxygen (up to 8 L/min) was administered via oronasal mask for 30 min, followed by HFNC at 30-50 L/min. Respiratory inductive plethysmography transducer bands were circumferentially placed: one around the rib cage, and one around the abdomen. We measured the movement of the rib-cage and abdomen, and used the sum signal to represent tidal volume (V(T)) during mask breathing, and at 30 min during HFNC. We calculated the ratio of maximum compartmental amplitude (MCA) to V(T), and the phase angle. We assessed arterial blood gas and vital signs at each period, and mouth status during HFNC. We used multiple regression analysis to identify factors associated with improvement in thoraco-abdominal synchrony. RESULTS: During HFNC, breathing frequency significantly decreased from 25 breaths/min (IQR 22-27 breaths/min) to 21 breaths/min (IQR 18-24 breaths/min) (P < .001), and MCA/VT (P < .001) and phase angle (P = .047) significantly improved. CONCLUSIONS: HFNC improved thoraco-abdominal synchrony in adult subjects with mild to moderate respiratory failure.


Assuntos
Abdome/fisiopatologia , Movimento/fisiologia , Ventilação não Invasiva/métodos , Oxigenoterapia/métodos , Insuficiência Respiratória/terapia , Tórax/fisiopatologia , Idoso , Catéteres , Estado Terminal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ventilação não Invasiva/instrumentação , Nariz , Oxigenoterapia/instrumentação , Estudos Prospectivos , Insuficiência Respiratória/fisiopatologia , Mecânica Respiratória
6.
Masui ; 63(10): 1164-6, 2014 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-25693354

RESUMO

BACKGROUND: Delayed discharge from ICU to the general ward can exert an adverse effect. We researched whether patients are discharged smoothly from our ICU to the general ward. METHODS: We defined that patients were eligible for discharge if they are without administration of catecholamine, being assisted by mechanical ventilation and having blood purification therapy. RESULTS: Average time from actual discharge to the time patient was considered eligible for discharge was fifteen hours. This study was retrospective. CONCLUSIONS: We need to investigate further the reasons why delayed discharge occurred. It is im portant that patients are discharged from the ICU to the general ward properly. Delayed discharge can delay the recovery and expose the patient to multi-resistant microorganisms. We studied whether patients are discharged smoothly from the ICU to the general ward.


Assuntos
Unidades de Terapia Intensiva/estatística & dados numéricos , Alta do Paciente/estatística & dados numéricos , Adulto , Idoso , Circulação Assistida , Catecolaminas , Infecção Hospitalar/prevenção & controle , Feminino , Hemofiltração , Humanos , Masculino , Pessoa de Meia-Idade , Quartos de Pacientes/estatística & dados numéricos , Respiração Artificial , Estudos Retrospectivos , Fatores de Tempo
7.
Am J Infect Control ; 41(3): 273-4, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22884495

RESUMO

We examined the incidence and types of bacterial contamination in 265 infusion set needles in adult critically ill patients. Bacterial contamination was detected in 15 samples (5.7%), and a total of 17 organisms were isolated. Ten were coagulase-negative staphylococci (CNS) and Staphylococcus aureus, and the remainder were α-Streptococcus, Corynebacterium, and gram-negative rods. Although the contamination was not directly related to catheter-related bloodstream infections exchanging infusion bottles can cause intraluminal contamination and is a possible route of these infections.


Assuntos
Bactérias/classificação , Bactérias/isolamento & purificação , Infecções Relacionadas a Cateter/etiologia , Agulhas/microbiologia , Adulto , Humanos , Incidência
8.
Case Rep Cardiol ; 2012: 393580, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24804110

RESUMO

Introduction. Cardiac failure during pregnancy is usually related to preeclampsia/eclampsia, rarely to hyperthyroidism. While hyperthyroidism can easily lead to hypertensive cardiac failure and may harm the fetus, it is sometimes difficult to distinguish hyperthyroidism from normal pregnancy. Case Presentation. We encountered a case of 41-year-old pregnant woman with hypertensive cardiac failure. Because we initially diagnosed as pre-eclampsia/eclampsia, Caesarian section was performed. However, her symptoms still persisted after delivery. After thyroid function test results taken on the day of admission were obtained on the fourth day, we could diagnose that her cardiac failure was caused by thyrotoxic crisis. Conclusions. Hypertensive cardiac failure due to hyperthyroidism during pregnancy is rare and difficult to diagnose because of similar presentation of normal pregnancy. However, physicians should be aware of the risks posed by hyperthyroidism during pregnancy.

9.
Am J Infect Control ; 40(6): 530-4, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22054688

RESUMO

BACKGROUND: Commonly placed to monitor blood pressure and to aspirate blood, arterial lines frequently cause complications. The blood conservation system (BCS) forms a closed infusion line and may be expected to reduce complications caused by intraluminal contamination. We compared microbial contamination resulting from use of BCS and 3-way stopcock catheterization. METHODS: Patients who required arterial catheterization for at least 24 hours in our intensive care unit were randomly assigned to receive an arterial pressure monitoring system either with the BCS (test group) or with a 3-way stopcock (comparator group). To evaluate arterial line contamination, we qualitatively assessed the contamination of the catheter tip and intraluminal fluid. RESULTS: We analyzed microbial contamination for a total of 216 arterial catheters: 109 in the test group and 107 in the comparator group. We found no difference in the incidence of catheter tip colonization in the 2 groups (test group, 8/109 vs comparator group, 11/107; P = .48). There was a statistically significant correlation between catheter tip colonization and duration of arterial line utilization. We found statistically significantly lower intraluminal fluid contamination in the test group (test group, 2/109 vs comparator group, 9/107; P = .03). There was no relationship between intraluminal fluid contamination and catheter tip contamination. CONCLUSION: There was less microbial contamination of intraluminal fluid when BCS was used for arterial catheterization.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Infecção Hospitalar/prevenção & controle , Contaminação de Equipamentos/prevenção & controle , Desenho de Equipamento/métodos , Dispositivos de Acesso Vascular/efeitos adversos , Dispositivos de Acesso Vascular/microbiologia , Adulto , Idoso , Estado Terminal , Feminino , Humanos , Incidência , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA