Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Acta Microbiol Immunol Hung ; 70(2): 134-141, 2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-36723933

RESUMO

Objectives: Methicillin-resistant Staphylococcus (MRS) has originated, spread extensively, and become a prominent source of bacterial infections in both human and animal. Methods: We report the prevalence, genetic diversity, and antimicrobial resistance pattern of Staphylococcus pseudintermedius and Staphylococcus aureus strains isolated from dogs and cats with eye discharges. Results: A total of 12 (6.0%) coagulase-positives staphylococci were identified as (6/200, 3%) S. aureus and (6/200, 3%) S. pseudintermedius. The phenotypic methicillin resistance of S. aureus and S. pseudintermedius were 50.0% (3/6) and 16.7% (1/6), respectively. None of the isolates showed biofilm formation in the microtiter plate assay. The highest resistance (50.0%) for S. pseudintermedius strains was detected against clindamycin and tetracycline. 67.0% of S. aureus isolates were resistant to penicillin-G. The PCR analysis conducted for detection of mecA gene indicated that only one S. aureus isolated from a cat was mecA gene positive. Phylogenetic analysis based on repetitive sequence-based PCR (rep-PCR) showed that all strains were typable and generated PCR products ranging from 800 bp to 4,400 bp. The lineages ST241 and the novel ST2361 in multi-locus sequence typing (MLST) analysis were detected in one methicillin-susceptible S. pseudintermedius and methicillin-resistant S. pseudintermedius of dogs, respectively. In addition, the lineages ST4155 and ST7217 of two methicillin-resistant S. aureus strains of cats were connected epidemiologically to previously reported cases. Conclusions: These results indicate epidemiologically related strains (ST241, ST4155, and ST7217) transferring between animals and humans. Therefore, the strategies to combat the widespread MRS should be based on collaboration between human and veterinary medicine under the One Health concept.


Assuntos
Doenças do Gato , Doenças do Cão , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Gatos , Cães , Humanos , Animais , Staphylococcus aureus , Tipagem de Sequências Multilocus , Resistência a Meticilina , Prevalência , Doenças do Gato/epidemiologia , Doenças do Gato/microbiologia , Alta do Paciente , Filogenia , Doenças do Cão/epidemiologia , Doenças do Cão/microbiologia , Staphylococcus/genética , Antibacterianos/farmacologia , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/veterinária , Infecções Estafilocócicas/microbiologia , Testes de Sensibilidade Microbiana
2.
Lasers Med Sci ; 38(1): 11, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36539645

RESUMO

This study aimed to investigate the effects on fracture healing of locally applied boric acid (BA) with and without low-level laser therapy (LLLT). A unicortical femoral defect was surgically created on the anterolateral surface of proximal femur of each subject. The subjects, totaling 56 Wistar albino rats, were randomly allocated into four groups (n = 14 each): control, LLLT (λ = 905 µm, 10,000 Hz, 25 mW, and peak power 25 W), BA (40 mg/kg), and BA + LLLT groups. On the 30th day, the highest radiological score was recorded for the BA + LLLT group (3.63 [2-4]), followed by the BA (3.38 [2.75-3.75]), control (3 [2-3.25]), and LLLT (2.5 [1.25-3]) groups. On days 15 and 30 post-surgery, malondialdehyde levels were significantly lower among the BA + LLLT group compared to the control group (p < 0.001). On day 30, superoxide dismutase, catalase, and alkaline phosphatase levels were highest in the BA + LLLT group compared to the control group (p < 0.001). When the histopathological, immunofluorescence, and immunohistochemical findings on the 15th and 30th days were compared with the control group, a statistically significant difference was found for the BA and BA + LLLT groups (p ˂ 0.05). This study suggests that locally applied BA with LLLT may accelerate fracture healing.


Assuntos
Terapia a Laser , Terapia com Luz de Baixa Intensidade , Animais , Ratos , Ácidos Bóricos/farmacologia , Ácidos Bóricos/uso terapêutico , Consolidação da Fratura , Ratos Wistar
3.
J Am Vet Med Assoc ; 261(2): 205-209, 2022 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-36322488

RESUMO

OBJECTIVE: To evaluate the accuracy for 2 smartwatches with oximetry technology and optical wrist heart rate (HR) or single-lead Electrocardiography (ECG) technology (Fenix 5X Plus [GF5xp], Garmin Ltd and Apple Watch 6 [AppW6], Apple Inc, respectively) versus reference methods (ECG and transmittance pulse oximetry [TPO], respectively) in measuring HR and peripheral oxygen saturation of hemoglobin (SpO2) in cats. ANIMALS: 10 male client-owned cats aged 8 to 12 months and weighing 3.2 to 4.5 kg. PROCEDURES: All cats that were presented for elective castration at the Atatürk University Animal Hospital between March 10 and April 15, 2022, were considered for enrollment. Monitoring of HR and SpO2 during anesthesia was performed with a 3-lead ECG and transmittance pulse oximetry, respectively, connected to a multiparameter monitor (reference methods) along with a GF5xp and a AppW6. Agreement between reference methods and the smartwatches were assessed by the Bland-Altman plot, in which the differences (%) between methods were plotted against their mean HR or SpO2 (reference method measurement - test device measurement) and the limits of agreement (mean ± 1.96 × SD). RESULTS: Compared with ECG measurements of HR, GF5xp had superior bias (-0.1%) and limit of agreement (LoA, 3.0 to -3.3%) versus those of the AppW6 (bias, 0.2%; LoA, 3.7 to -3.4%). Compared with TPO measurements of SpO2, AppW6 had superior bias (0.2%) and LoA (3.0% and -2.5%) versus those of the GF5xp (bias, -2.1%; LoA, 0.2 to -4.4%). CLINICAL RELEVANCE: Results indicated that the GF5xp and AppW6 exhibited high accuracy in evaluating HR and SpO2 in cats when compared with the reference methods. However, it should be noted that these comparisons were made in anesthetized patients without any systemic disease.


Assuntos
Saturação de Oxigênio , Oxigênio , Masculino , Gatos , Animais , Frequência Cardíaca , Oximetria/veterinária , Oximetria/métodos , Eletrocardiografia
4.
Top Companion Anim Med ; 49: 100654, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35276420

RESUMO

This study was aimed to evaluate the accuracy of heart rate (HR) measurements using 3 smartwatch models designed for human use when applied to dogs. A group of 15 mixed breed dogs, ages ranging from 2 to 3 years, weighing between 20 and 30 kg were used. The Garmin Fenix 5X plus (GF5Xp), Samsung Gear S3 (SGS3), and Polygold A-6 (PDA6), were randomly placed on the tibia of dogs to collect the HR recordings every 5 minutes for 1 hour. A veterinary patient monitor (VPM) was used as the reference method. A Bland-Altman plot was applied to determine the difference between smartwatches. The receiver operating characteristic curves were developed analysis for sensitivity and specificity. The HR measured by VPM ranged from 65 to 200 bpm (mean, 149.3 ± 28.1 bpm; median, 154 bpm). Among the smartwatches, the lowest (44 bpm) HR was measured by PDA6, while the highest (201 bpm) was measured by SGS3. Among the smartwatches; GF5Xp and SGS3 had slopes equal to 1 and residual standard deviation closer to 0, in agreement with VPM. At the cut-off HR (160 bpm), SGS3 had the highest sensitivity (97.4%), whereas PDA6 had the lowest sensitivity (68.0%). The specificity of GF5Xp, SGS3, and PDA6 was 97.1%, 98.0%, and 98.0%, respectively. The SGS3 and GF5Xp can be ideal tools for veterinarians to monitor the HR of dogs without requiring an additional device.


Assuntos
Frequência Cardíaca , Animais , Cães , Frequência Cardíaca/fisiologia , Sensibilidade e Especificidade
5.
Vet Anaesth Analg ; 49(1): 113-117, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34802925

RESUMO

OBJECTIVE: To compare the sedative and cardiopulmonary effects of intranasal (IN) and intramuscular (IM) administration of dexmedetomidine and midazolam combination in New Zealand White rabbits. STUDY DESIGN: A randomized, crossover experimental study. ANIMALS: A total of eight healthy New Zealand White rabbits, aged 6-12 months, weighing 3.1 ± 0.3 kg (mean ± standard deviation). METHODS: The animals were randomly assigned to administration of dexmedetomidine (0.1 mg kg-1) with midazolam (2 mg kg-1) by either IN or IM route separated by 2 weeks. The electrocardiogram, pulse rate (PR), peripheral haemoglobin oxygen saturation (SpO2), mean noninvasive arterial pressure (MAP), respiratory frequency (fR) and rectal temperature were measured before drug administration (baseline), T0 (onset of sedation) and at 5 minute intervals until recovery. The onset of sedation, duration of sedation and sedation score (SS) were also recorded. RESULTS: The PR was significantly lower in treatment IM than in treatment IN over time (p = 0.027). MAP < 60 mmHg developed in two and four rabbits in treatments IN and IM, respectively. SpO2 progressively decreased over time in both treatments. fR was lower than baseline at several time points in both treatments. Onset of sedation was shorter in treatment IN (90 ± 21 seconds) than in treatment IM (300 ± 68 seconds) (p = 0.036). Duration of sedation was longer in treatment IM (55.2 ± 8.7 minutes) than in treatment IN (39.6 ± 2.1 minutes) (p = 0.047). No significant difference in SS was observed between treatments (p > 0.05). CONCLUSIONS AND CLINICAL RELEVANCE: Combination of dexmedetomidine (0.1 mg kg-1) and midazolam (2 mg kg-1) decreased fR, PR and SpO2 regardless of the administration route in New Zealand White rabbits. A more rapid action and shorter duration of sedation were observed after treatment IN than after treatment IM administration.


Assuntos
Dexmedetomidina , Midazolam , Administração Intranasal/veterinária , Animais , Dexmedetomidina/farmacologia , Frequência Cardíaca , Hipnóticos e Sedativos/farmacologia , Injeções Intramusculares/veterinária , Midazolam/farmacologia , Saturação de Oxigênio , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA