Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Injury ; 54(7): 110770, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37183089

RESUMO

INTRODUCTiON: It is estimated that 5-30% of traumatic anterior shoulder dislocations are accompanied by greater tuberosity fracture (GTF), and the pathomechanism of these fractures is not yet clear. Our hypothesis is to examine the relationship between the scapula morphology and anterior shoulder dislocation (ASD) accompanying GTF. MATERiALS AND METHODS: The patients were divided into two groups according to the accompanying GTF. 40 patients with isolated traumatic ASD and 31 patients with accompanying GTF were included in the study. Critical shoulder angle (CSA), glenoid inclination (GI), acromial index (AI) and greater tuberosity angle (GTA) values were measured in two sessions by two independent observers in the standard antero-posterior radiographs of the patients in both groups. RESULTS: The mean CSA was 40.82°±3.19° and 35.49°±2.19° in accompanying GTF group and the isolated ASD group, respectively. The mean CSA was significantly higher in accompanying GTF group than isolated ASD group(P<0.001). The GI was significantly higher in the isolated ASD than in accompanying GTF group (P = 0.001). The mean GI was 18.7°±6.85° and 10.45°±4.87° in accompanying GTF group and the isolated ASD, respectively. Cut-off value of CSA and GI was 38° (88.2% sensitivity,88.9% specificity) and 14.5° (70.6% sensitivity and 72.2% specificity), respectively. There was no significant difference regarding the mean GTA and AI values between GTF group and the isolated ASD group (P = 0.98, P = 0.63). CONCLUSiONS: Increased CSA and GI values are associated with traumatic anterior shoulder dislocation accompanied by greater tuberosity fracture.


Assuntos
Lesões do Manguito Rotador , Luxação do Ombro , Fraturas do Ombro , Articulação do Ombro , Humanos , Luxação do Ombro/diagnóstico por imagem , Escápula/diagnóstico por imagem , Radiografia , Fraturas do Ombro/diagnóstico por imagem , Estudos Retrospectivos
2.
J Foot Ankle Surg ; 62(4): 666-670, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36941139

RESUMO

The anterior talofibular ligament (ATFL) is the first to be damaged during a lateral ankle sprain. Dynamic and static structures have been investigated to better understand ATFL rupture, but the predisposing factors have not been fully elucidated. This study aims to define the fibular notch version that can evaluate the position of the fibular notch relative to the tibia and investigate the relationship between the fibular notch version (FNV) and ATFL rupture. This study included 71 patients with isolated ATFL rupture diagnosed clinically and radiologically and 71 control patients without any foot or ankle pathologies. Anterior facet length (AFL), posterior facet length (PFL), anterior-posterior facet angle (APFA), fibular notch depth (ND), and FNV measurements were performed on axial magnetic resonance images (MRI). We defined FNV as a parameter that evaluates the fibular notch's relative position to the distal tibia. The mean FNV was 16.6° ± 4.9° in patients with ATFL rupture and 12.4° ± 5.6° in the control group; when both groups were compared, FNV measurements were significantly higher in patients with ATFL rupture (p = .002). The mean APFA was 123.9° ± 10° in the group with ATFL rupture and 129.7° ± 7.8° in the control group. When both groups were compared, APFA was significantly lower in patients with ATFL rupture (p = .014). There was no significant difference between the groups regarding AFL, PFL, and ND. A more posterior (retroverted) fibular notch and a lower fibular notch angle seem to be associated with higher rates of ATFL rupture.


Assuntos
Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Ligamentos Laterais do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Tornozelo , Imageamento por Ressonância Magnética , Fíbula/diagnóstico por imagem , Instabilidade Articular/cirurgia , Cadáver
3.
Injury ; 53(11): 3828-3832, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36116961

RESUMO

Background The purpose of this study was to compare the effects of different distances between the end point of the osteotomy and the lateral cortex on the risk of lateral cortical fracture in the medial opening-wedge high tibial osteotomy (MOWHTO) procedure. Methods Eighteen synthetic tibia models were used. Saw cuts were performed on the test models (n=6 for all groups). Wedge gap distance and wedge opening load were evaluated using compression tests. Findings The mean maximum gap distance without a lateral cortical fracture was 19.90 mm in Group 5, 15.49 mm in Group 10, and 11.23 mm in Group 15. The differences between Group 5 and Group 10, Group 5 and Group 15, and Group 10 and Group 15 were statistically significant. The mean load just before the fracture was 13.24 N in Group 5, 18.31 N in Group 10, and 26.16 N in Group 15. The difference between Group 5 and Group 15 was statistically significant. No significant difference was observed between Group 10 and both Group 5 and Group 15. Interpretation As the end point of the osteotomy is brought gradually closer to the lateral cortex, wider gaps can be opened without a lateral cortical fracture. Thus, higher angle corrections can be achieved more safely by bringing the end point of the osteotomy closer to the lateral cortex, which should be preferred to reduce the risk of a lateral cortical hinge fracture during the MOWHTO procedure, from a clinical viewpoint.


Assuntos
Fraturas Ósseas , Osteoartrite do Joelho , Humanos , Osteotomia/métodos , Tíbia/cirurgia , Próteses e Implantes , Articulação do Joelho/cirurgia
4.
Jt Dis Relat Surg ; 33(2): 399-405, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35852200

RESUMO

OBJECTIVES: This study aimed to define the medial meniscus posterior base angle (MMPBA) and the lateral meniscus posterior base angle (LMPBA) measured in the medial and lateral meniscus posterior horns and examine the biomechanical and morphological relationship between anterior cruciate ligament (ACL) injuries and posterior meniscus horns using these parameters. PATIENTS AND METHODS: The retrospective study was conducted with 32 patients with ACL rupture and 40 control patients, for a total of 72 patients (40 males, 32 females; mean age: 36.3±9.9 years; range, 18 to 57 years), between January 2016 and January 2018. The posterior tibial slope (PTS) was measured in standard radiographs, and MMPBA and LMPBA values were assessed by standard knee magnetic resonance imaging. The MMPBA was defined as the angle between the line passing through the medial meniscus' tibial side border and the line passing through the capsular side border in the sagittal section's medial meniscus posterior horn. The LMPBA was defined as the angle between the line passing through the lateral meniscus' tibial side border and the line passing through the capsular side border on the sagittal section's lateral meniscus posterior horn. Groups were compared for PTS, MMPBA, and LMPBA. RESULTS: When both groups were compared in terms of MMPBA and LMPBA, patients with ACL rupture had significantly higher base angles (p<0.001 and p=0.031, respectively). The mean MMPBA was 84.27º±12.59º (range, 62º to 106.1º) in patients with ACL rupture, while it was 70.75º±7.85º (range, 55.1º to 88.6º) in the control group. The mean LMPBA was 83.62º±11.4º (range, 62.3º to 105.9º) in patients with ACL rupture, while it was 76.94º±11.46º (range, 30.8º to 96.5º) in the control group. In the receiver operating characteristics curve analysis, the cut-off value of MMPBA was 84.5, and values above this showed a 58.5% sensitivity and a 97.6% specificity for ACL rupture, whereas for LMPBA, the cut-off value was 93.15, and values above this showed a 27.3% sensitivity and a 95.1% specificity for ACL rupture. The PTS and MMPBA were significantly correlated with each other (p=0.047). The MMPBA and LMPBA were also significantly correlated with each other (p=0.011). However, there was no significant correlation between PTS and LMPBA (p=0.56). CONCLUSION: Medial meniscus posterior base angle and LMPBA values above 84.5º and 93.15º, respectively, are new indirect magnetic resonance imaging findings of ACL injury.


Assuntos
Lesões do Ligamento Cruzado Anterior , Lesões do Menisco Tibial , Adulto , Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Meniscos Tibiais , Pessoa de Meia-Idade , Estudos Retrospectivos , Lesões do Menisco Tibial/diagnóstico por imagem
5.
Acta Orthop Belg ; 84(1): 84-93, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30457505

RESUMO

The objective of our study was to assess the functional and sensory outcomes of the primary repair of 138 digital nerve injuries in 48 consecutive patients between January 2012 and November 2014, and to determine whether there were any relationships between demographics, clinical characteristics, or functional test results and post-operative sensory recovery outcomes. Mean follow-up was 14 (range, 10 to 20) months. Sensory evaluation was performed using the static two-point discrimination test, and post-operative sensoryrecovery results were classified according to the Seddon Classification: 69 (50%) injuries were S3+, 3 (2%) were S3, 15 (11%) were S2, 18 (13%) were S1, and 33 (24%) were S0. Sensory recovery was associated with time between surgery and testing and with objective functional recovery. More than half of digits sustaining nerve injuries had good intermediate-term recovery of sensation after early primary surgical repair. Surgeon experience and early primary repair may have a favorable impact on results.


Assuntos
Mãos/cirurgia , Traumatismos dos Nervos Periféricos/cirurgia , Recuperação de Função Fisiológica/fisiologia , Adolescente , Adulto , Avaliação da Deficiência , Feminino , Mãos/inervação , Mãos/fisiopatologia , Força da Mão/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/fisiopatologia , Resultado do Tratamento , Adulto Jovem
6.
Knee Surg Sports Traumatol Arthrosc ; 25(9): 2914-2920, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26897136

RESUMO

PURPOSE: The purpose of this study was to investigate the mechanical strength of both monoplanar and biplanar medial opening-wedge high tibial osteotomy (MOWHTO) procedures and assess the risk of lateral cortex disruption for both techniques. METHODS: Twelve synthetic tibia models with cortical shells were used as test models. Saw cuts for monoplanar MOWHTO and biplanar MOWHTO were generated on the test models in equal numbers (n = 6 for both groups). Wedge opening load and wedge gap distance were evaluated via compressive tests. RESULTS: The mean gap distance just before the lateral cortex fracture in the monoplanar group was 14.7 ± 2.9 mm, which was significantly narrower than that in the biplanar group of 19.1 ± 2.0 mm (p = 0.015). The mean load just before the occurrence of lateral cortex fracture of 32.4 ± 3.2 N in the monoplanar osteotomy group was significantly lower than that in the biplanar osteotomy group of 111.8 ± 9.3 N (p = 0.009). CONCLUSION: Performing a MOWHTO via the biplanar rather than the monoplanar technique allows larger-sized wedges to be opened with less risk of lateral cortical fracture. Thus, larger gaps can be opened and higher angle corrections can be achieved using the biplanar osteotomy procedure. From a clinical viewpoint, the biplanar osteotomy technique reduced the risk of lateral cortical hinge fracture during MOWHTO.


Assuntos
Osteotomia/métodos , Tíbia/cirurgia , Fraturas da Tíbia/prevenção & controle , Humanos , Modelos Biológicos , Osteotomia/efeitos adversos , Estresse Mecânico , Suporte de Carga
7.
Plast Reconstr Surg Glob Open ; 4(10): e1022, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27826460

RESUMO

BACKGROUND: To evaluate the efficiency of the percutaneous 18-G needle technique in releasing the fibro-osseous sheath over the first dorsal extensor compartment of the hand. METHODS: Using anatomic landmarks, percutaneous release was performed with an 18-G needle on 48 wrists of 24 cadavers. The specimens were then dissected and examined for the completeness of the first dorsal extensor compartment release and any tendon or neurovascular injuries. The tunnel length, number of abductor pollicis longus and extensor pollicis brevis tendons, presence of an intertendinous septum, and the effects of these parameters on percutaneous release were evaluated. RESULTS: Percutaneous release was performed on all of the wrists, and the evaluation of the adequacy of release revealed 25 complete releases, 21 partial releases, and 2 missed releases. There were 19 cases of tendon complications. No neurovascular injuries were noted. The mean tunnel length was 2.66 ± 30 cm, and the mean number of tendons was 2.75 ± 0.86. A septum was present in 33.3% of cases. Tunnel length and tendon number had no statistically significant effect on release, whereas the presence of a septum was significantly associated with inadequate tunnel release and the development of tendon complications. CONCLUSIONS: Percutaneous release of the first dorsal extensor compartment using an 18-G needle was associated with high rates of incomplete release and tendon damage in the presence of an intertendinous septum. Further study is required under ultrasound guidance to determine the usefulness of percutaneous release in the first dorsal extensor compartment. CLINICAL RELEVANCE: Release with a percutaneous needle tip in De Quervain's syndrome may provide the advantages of better cosmetic results with less scar formation and an early return to work.

8.
Ulus Travma Acil Cerrahi Derg ; 22(5): 483, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27849326

RESUMO

BACKGROUND: Supracondylar humerus fracture is the most common fracture of the elbow in children. Closed reduction and percutaneous pinning is considered to be the optimal treatment strategy; however, in some instances, open reduction may be necessary. The aim of this retrospective study was to compare clinical and functional results of triceps-splitting posterior versus lateral approach in pediatric supracondylar humerus fracture surgery. METHODS: A total of 38 patients underwent surgery; Group 1 consisted of 30 patients on whom posterior approach was used, while lateral approach was used on the 8 patients in Group 2. Flynn criteria were used to evaluate cosmetic and clinical results. Fracture healing was assessed with anteroposterior and lateral x-rays. Patients and parents were asked to describe time needed for complete return of full elbow range of motion (ROM) and overall satisfaction. RESULTS: Mean fracture union time was 44.1 days and 46.3 days, and time required to regain complete or near complete elbow ROM was 57.5 days and 55.7 days after splint removal for Group 1 and Group 2, respectively. Twenty-one of 30 (70%) patients (and parents) in Group 1, and 6 of 8 (75%) patients (and parents) in Group 2 were totally satisfied with the results. Twenty-one of 30 (70%) patients in Group 1, and 6 of 8 (75%) patients in Group 2 had excellent cosmetic and functional results according to Flynn outcome criteria. CONCLUSION: In cases of pediatric supracondylar humerus fracture, early closed reduction and percutaneous pinning is preferred; however, when this method is not applicable, triceps-splitting posterior approach is a safe and comparable method to lateral approach with advantages of easier fracture reduction and shorter operating time.


Assuntos
Pinos Ortopédicos , Cotovelo/cirurgia , Fraturas do Úmero/cirurgia , Criança , Pré-Escolar , Feminino , Fixação Intramedular de Fraturas , Consolidação da Fratura , Humanos , Fraturas do Úmero/diagnóstico por imagem , Masculino , Duração da Cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Turquia
9.
Knee Surg Sports Traumatol Arthrosc ; 24(9): 3011-3020, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25931128

RESUMO

PURPOSE: Anterior knee pain is a common musculoskeletal condition amongst young adult population. Lower extremity structural factors, such as increased femoral anteversion and lateral tibial torsion, may contribute to patellofemoral malalignment and anterior knee pain. The aim of this study was to evaluate the lower extremity structural factors and related patellofemoral alignment parameters that play a role in the aetiology of anterior knee pain. METHODS: This study involved three groups: patients with unilateral symptomatic knees (n = 35), asymptomatic contralateral knees in the same patients and a control group (n = 40). All subjects were physically examined, and Q-angles were measured. The lower extremities of all subjects were imaged by a very low-dose CT scan, and the symptomatic knees of patients were compared with their asymptomatic contralateral knees and with the healthy knees of controls regarding femoral anteversion, tibial torsion, sulcus angle, patellar tilt angle and lateral patellar displacement. RESULTS: Regarding the Q-angle, femoral anteversion and lateral tibial torsion, no significant differences were found between the symptomatic and asymptomatic knees, whereas significant differences were found between the symptomatic knees and controls. The symptomatic group demonstrated significantly greater sulcus angle only in 30° of knee flexion than did the controls. CONCLUSION: Patients with unilateral anterior knee pain may have similar morphology at their contralateral asymptomatic lower extremity, and different morphology compared with healthy controls. Lower extremity rotational deformities may increase the risk of anterior knee pain; however, these deformities alone are not sufficient to cause knee pain, and may be predisposing factor rather than a direct aetiology. LEVEL OF EVIDENCE: Diagnostic study, Level III.


Assuntos
Artralgia/etiologia , Artralgia/fisiopatologia , Dor Crônica/etiologia , Dor Crônica/fisiopatologia , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/fisiopatologia , Adulto , Feminino , Fêmur/fisiopatologia , Humanos , Articulação do Joelho/diagnóstico por imagem , Extremidade Inferior , Masculino , Patela/fisiopatologia , Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X , Adulto Jovem
10.
Asian Spine J ; 9(5): 713-20, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26435789

RESUMO

STUDY DESIGN: A single-center, retrospective patient review of clinical and radiological outcomes of microsurgical posterior lumbar interbody fusion and decompression, without posterior instrumentation, for the treatment of lateral recess stenosis. PURPOSE: This study documented the clinical and radiological results of microsurgical posterior lumbar interbody fusion and decompression of the lateral recess using interbody cages without posterior instrumentation for the treatment of lateral recess stenosis. OVERVIEW OF LITERATURE: Although microsurgery has some advantages, various complications have been reported following microsurgical decompression, including cage migration, pseudoarthrosis, neurologic deficits, and persistent pain. METHODS: A total of 34 patients (13 men, 21 women), with a mean age of 56.65±9.1 years (range, 40-77 years) confirmed spinal stability, and preoperative radiological findings of lateral recess stenosis, were included in the study. Interbody polyetheretherketone cages and auto grafts were used in all patients. Posterior instrumentation was not used because of limited resection of the posterior lumbar structures. Preoperative and postoperative radiographs, computed tomography scans, and magnetic resonance imaging were assessed and compared to images taken at the final follow-up. Functional recovery was also evaluated according to the Macnab criteria at the final follow-up. RESULTS: The average follow-up time was 35.05±8.65 months (range, 24-46 months). The clinical results, operative time, intraoperative blood loss, and duration of hospital stay were similar to previously published results; the fusion rate (85.2%) was decreased and the migration rate (5.8%) was increased, compared with prior reports. CONCLUSIONS: Although microsurgery has some advantages, migration and pseudoarthrosis remain challenges to achieving adequate lumbar interbody fusion.

11.
Int J Clin Exp Med ; 8(7): 11563-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26379982

RESUMO

PURPOSE: Q-angle measurement procedure have not been well standardised. There is a lack of consensus about subject position and knee flexion angle while measuring the Q-angle. Morover Q-angle value which obtained in a single position is a static value and gives an information about the subject's current position. The aim of this study is to obtain a more significant parameter which includes different postures (supine, standing, sitting) and different knee flexion angles instead of a single Q-angle in a fixed position. At the same time this parameter must be functional and dynamic,not a static value like Q-angle. We named this parameter as ΔQ. METHODS: Our study was applied on case and control groups. All subjects in both groups were male. Case group was consisted of 14 subjects who had patellofemoral pain. Control group was consisted of 14 subjects who had normal knees and normal lower extremities with no reported knee problems. We obtained 3 different Q-angle values and 3 different ΔQ values for each subject in both groups. Pearson correlation analysis was used for investigation of continuous variables in normal distribution, Spearman correlation analysis was used in abnormal distribution. t test was used in the comparison of values. Logistic regression analysis(forward conditional mod) was used for detecting of determinants of pain. RESULTS: ΔQ1s of both groups were found as the only statistical significant predictive value for patellofemoral pain. CONCLUSION: There is not an agreement about a standardised q-angle measurement procedure in the literature. Moreover, present procedures provide information about a single and fixed position. In this situation Q-angles which obtained in these fixed positions are static values. We think that we can overcome these problems with this new value. ΔQ contains multiple q-angles and gives information about all. Also it is a dynamic value for being oriented to position change. Therefore, ΔQ is an useful indicator for evaluating patellofemoral pain.

12.
J Hand Surg Am ; 40(8): 1591-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26070233

RESUMO

PURPOSE: To compare the outcomes and associated costs of the treatment of mallet fractures with either extension block pinning or open reduction and hook plate fixation. METHODS: We treated 22 patients for a mallet fracture that involved at least 25% of the distal phalanx articular surface. Three joints demonstrated concomitant volar subluxation. Extension block pinning was used to treat 16 fractures (group 1) and 6 were treated with open reduction and hook plate fixation (group 2). All patients were evaluated at the second, fourth, and sixth weeks after surgery. Collected data included range of motion, extensor lag, and pain status. Patients were asked to grade preoperative and postoperative pain levels on a visual analog scale. Functional outcomes were determined by Crawford criteria. We retrospectively performed a cost analysis using our institutional records. RESULTS: Mean follow-up was 12.7 months. Visual analog scale pain scores improved by a similar amount for both groups. Preoperative pain scores were 7.0 for group 1 and 7.5 for group 2. Postoperative levels were 2.0 and 2.0, respectively. Mean extensor lag was identical for both groups, 5°. Mean flexion was 70° for group 1 and 80° for group 2. Based on the Crawford criteria, group 1 had 5 patients rated as excellent, 6 as good, 3 as fair, and 2 as poor. Group 2 outcomes were 2 excellent, 2 good, and 2 fair. Five complications occurred in group 1, and 1 in group 2. Differences noted between groups were not statistically significant. Extension block pinning was more cost-effective than hook plate fixation. CONCLUSIONS: We find extension block pinning to be an equally effective but more cost-efficient treatment than open reduction and hook plate fixation. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic III.


Assuntos
Placas Ósseas , Falanges dos Dedos da Mão/lesões , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fraturas Intra-Articulares/cirurgia , Adolescente , Adulto , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
13.
Autops Case Rep ; 5(4): 71-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26894048

RESUMO

A ganglion cyst (GC) is a mucinous or gelatinous-filled benign tumor overlying a joint or tendon sheath, which commonly arises in the dorsal and volar wrist side but may occur anywhere in the body. Although cystic lesions around the knee are common, the occurrence of GCs are rare. Ganglia may arise from intra or extra-articular, soft tissue, intraosseous, or periosteal location. Symptoms may vary according to the size and location. After the more frequent performance of magnetic resonance imaging for the assessment of a knee joint, the number of incidental, asymptomatic lesions have been increasingly diagnosed. The etiology of GC remains unclear; however, trauma and a flaw in the joint tissues may explain its appearance. The authors report two cases of women aged 47 years and 37 years who presented pain and swelling in their left knees following arthroscopic partial medial meniscectomy. The former was surgically treated and had a favorable outcome, while the latter had conservative treatment and a gloomy outcome.

14.
Eur J Orthop Surg Traumatol ; 25(4): 723-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25274204

RESUMO

OBJECTIVES: To evaluate the midterm outcome and the degree of satisfaction of patients who underwent reconstruction of dorsal hand and finger defects with reverse flow radial fasciocutaneous forearm flaps and to test whether or not this is a reliable method which can be applied without the need for microsurgery. PATIENTS AND METHODS: Eleven patients were admitted with post-traumatic complex hand defects and treated by reconstruction with reverse flow radial fasciocutaneous forearm flaps from January 2010 to May 2013. The patient demographics, size of the hand and finger defects, and complications were recorded. The functional status of each of the patients was evaluated using the quick disabilities of the arm, shoulder and hand (DASH) scoring system, and patient satisfaction was assessed using Likert scores. RESULTS: The patients comprised nine males and two females with a mean age of 30.7 ± 9.7 years. The mean follow-up period was 18.4 ± 5.2 months. The average defect size was 41 ± 14.3 cm². None of the patients had circulation defects caused by the sacrifice of the radial artery. The mean quick DASH score was determined as 30.2 ± 15.3. The Likert patient satisfaction evaluation was good in one patient, and very good in ten patients. All flaps survived well with only two complications; superficial skin necrosis occurred at the suture site in one patient and venous insufficiency occurred in the other patient. Both complications recovered with secondary healing following wound debridement. CONCLUSIONS: The reverse-flow radial forearm flap is a reliable method in the management of dorsal defects of the hand and does not require micro-surgical techniques.


Assuntos
Traumatismos da Mão/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Retalhos Cirúrgicos , Adolescente , Adulto , Criança , Feminino , Traumatismos dos Dedos/cirurgia , Antebraço , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
15.
Injury ; 45(10): 1569-73, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25037528

RESUMO

AIM: Hand trauma may lead to multiple fingertip defects, causing functional restrictions. We evaluated the use of reverse-flow homodigital flap reconstruction of the distal phalanx and pulp defects associated with multiple finger injuries. METHODS: We retrospectively evaluated 11 male patients who presented at our emergency department (January 2011-March 2013) with multiple fingertip injuries and who were treated with a reverse-flow homodigital flap. Evaluations included age, sex, defect size, flap survival rate, complications, cold intolerance, two-point discrimination, range of motion (ROM), quick disabilities of the arm, shoulder, and hand (DASH) score, and return to work time. RESULTS: Completely, 22 reverse-flow homodigital flaps were applied to at least two fingertip injuries at the distal phalanx. Ten flaps survived postoperatively. The exception was partial flap loss on one finger. The mean follow-up was 14.2 months. At the final follow-up, the mean static two-point discrimination value was 10.3mm. Mean ROMs of interphalangeal joints were 65.31° (distal) and 105.77° (proximal). Donor sites were covered with full-thickness skin grafts from the wrist or antecubital area. There were no complications related to the donor site and no development of cold intolerance in any finger. The mean quick DASH score was 4.12. All patients returned to work in an average of 8.3 weeks. CONCLUSIONS: The reconstruction of multiple fingertip injuries with reverse-flow homodigital flaps is a safe, effective method that can be combined with other local finger flaps. These flaps can be applied to two consecutive fingers without reducing finger length or function.


Assuntos
Amputação Traumática/cirurgia , Traumatismos dos Dedos/cirurgia , Procedimentos de Cirurgia Plástica , Retalhos Cirúrgicos , Adolescente , Adulto , Traumatismos dos Dedos/fisiopatologia , Humanos , Masculino , Amplitude de Movimento Articular , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Retorno ao Trabalho , Sensação , Retalhos Cirúrgicos/irrigação sanguínea , Retalhos Cirúrgicos/inervação , Resultado do Tratamento
16.
Case Rep Orthop ; 2014: 647491, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25002980

RESUMO

The bucket-handle meniscal tear is a specific type of meniscal injuries which has specific signs on MRI. An attached fragment displaced away from the meniscus with any type of tear causes bucket-handle tear of the meniscus. Magnetic resonance imaging (MRI) is the most commonly used diagnostic tool for meniscal injuries. We present a case of free medial meniscal fragment which mimics the dislocated bucket-handle tear on MRI. The presence of "fragment within the intercondylar notch sign" and "the absence of the bow tie sign" may be an indication of a free meniscal fragment. This should be considered during diagnosis.

17.
Eur J Orthop Surg Traumatol ; 24(8): 1549-55, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24452434

RESUMO

PURPOSE: Medial opening-wedge high tibial osteotomy (MOWHTO) is an effective surgical procedure for patients who have medial compartmental osteoarthritis of the knee with varus deformity of the limb. The abnormal load on the medial compartment of the knee is directed to the lateral compartment with this procedure. A gap occurs on the proximal tibia while providing adequate correction. Filling this gap with bone grafts or synthetic materials has gained wide acceptance for preventing bone union problems or osteotomy site collapse. The aim of this study is to report our results of MOWHTOs performed without any bone graft or any other synthetic materials. METHODS: We evaluated 41 MOWHTOs that have been performed between 2009 and 2012 with no use of any grafts or synthetic materials and spacer. Age of the patients ranged from 43 to 67. Thirty-five of the patients were females and three of them were males. The follow-up time was 6 months. RESULTS: Seven knees had opening at the osteotomy site <10 mm, 26 knees had 10-12.5 mm, and eight knees had >12.5 mm (range 7.5-14 mm, mean 11.07 mm). All osteotomies united without loss of correction. The mean bone union time was 12.8 weeks. We did not have any major complication regarding the technique. CONCLUSION: The results of our study have shown that we can achieve satisfactory and good results by performing MOWHTO procedure without using any bone grafts or synthetic materials and spacer.


Assuntos
Placas Ósseas , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Tíbia/cirurgia , Adulto , Idoso , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteotomia/instrumentação , Período Pós-Operatório , Radiografia , Estudos Retrospectivos , Tíbia/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA