Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Front Oncol ; 12: 921473, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36313653

RESUMO

Purpose: We investigated the feasibility of biology-guided radiotherapy (BgRT), a technique that utilizes real-time positron emission imaging to minimize tumor motion uncertainties, to spare nearby organs at risk. Methods: Volumetric modulated arc therapy (VMAT), intensity-modulated proton (IMPT) therapy, and BgRT plans were created for a paratracheal node recurrence (case 1; 60 Gy in 10 fractions) and a primary peripheral left upper lobe adenocarcinoma (case 2; 50 Gy in four fractions). Results: For case 1, BgRT produced lower bronchus V40 values compared to VMAT and IMPT. For case 2, total lung V20 was lower in the BgRT case compared to VMAT and IMPT. Conclusions: BgRT has the potential to reduce the radiation dose to proximal critical structures but requires further detailed investigation.

3.
Int J Radiat Oncol Biol Phys ; 96(4): 793-800, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27788952

RESUMO

PURPOSE: We prospectively compared computed tomography (CT)- and magnetic resonance imaging (MRI)-based high-risk clinical target volume (HR-CTV) contours at the time of brachytherapy for cervical cancer in an effort to identify patients who might benefit most from MRI-based planning. METHODS AND MATERIALS: Thirty-seven patients who had undergone a pretreatment diagnostic MRI scan were included in the analysis. We delineated the HR-CTV on the brachytherapy CT and brachytherapy MRI scans independently for each patient. We then calculated the absolute volumes for each HR-CTV and the Dice coefficient of similarity (DC, a measure of spatial agreement) for the HR-CTV contours. We identified the clinical and tumor factors associated with (1) a discrepancy in volume between the CT HR-CTV and MRI HR-CTV contours; and (2) DC. The mean values were compared using 1-way analysis of variance or paired or unpaired t tests, as appropriate. Simple and multivariable linear regression analyses were used to model the effects of covariates on the outcomes. RESULTS: Patients with International Federation of Gynecology and Obstetrics stage IB to IVA cervical cancer were treated with intracavitary brachytherapy using tandem and ovoid (n=33) or tandem and cylinder (n=4) applicators. The mean CT HR-CTV volume (44.1 cm3) was larger than the mean MRI HR-CTV volume (35.1 cm3; P<.0001, paired t test). On multivariable analysis, a higher body mass index (BMI) and tumor size ≥5 cm with parametrial invasion on the MRI scan at diagnosis were associated with an increased discrepancy in volume between the HR-CTV contours (P<.02 for both). In addition, the spatial agreement (as measured by DC) between the HR-CTV contours decreased with an increasing BMI (P=.013). CONCLUSIONS: We recommend MRI-based brachytherapy planning for patients with tumors >5 cm and parametrial invasion on MRI at diagnosis and for those with a high BMI.


Assuntos
Braquiterapia/métodos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Índice de Massa Corporal , Braquiterapia/instrumentação , Fracionamento da Dose de Radiação , Feminino , Humanos , Pessoa de Meia-Idade , Invasividade Neoplásica , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Análise de Regressão , Carga Tumoral , Neoplasias do Colo do Útero/patologia
4.
Med Dosim ; 36(4): 383-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21144734

RESUMO

The pattern of failure is one of the major causes of mortality among thoracic patients. Studies have shown a correlation between local control and dose. Intensity-modulated radiation therapy (IMRT) has resulted in conformal dose distributions while limiting dose to normal tissue. However, thoracic malignancies treated with IMRT to highly conformal doses up to 70 Gy still have been found to fail. Thus, the need for dose escalation through simultaneous integrated boost (SIB) may prove effective in minimizing reoccurrences. For our study, 28 thoracic IMRT plans were reoptimized via dose escalation to the gross tumor volume (GTV) and planning target volume (PTV) of 79.2 Gy and 68.4 Gy, respectively. Reoccurrences in surrounding regions of microscopic disease are rare therefore, dose-escalating regional nodes (outside GTV) were not included. Hence, the need to edit GTV margins was acceptable for our retrospective study. A median dose escalation of approximately 15 Gy (64.8-79.2 Gy) via IMRT using SIB was deemed achievable with minimal percent differences received by critical structures compared with the original treatment plan. The target's mean doses were significantly increased based on p-value analysis, while the normal tissue structures were not significantly changed.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Recidiva Local de Neoplasia/prevenção & controle , Radiometria , Dosagem Radioterapêutica , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA