Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(6): 1281-1289, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35362175

RESUMO

INTRODUCTION: Dofetilide suppresses atrial fibrillation (AF) in a dose-dependent fashion. The protective effect of AF against QTc prolongation induced torsades de pointe and transient post-cardioversion QTc prolongation may result in dofetilide under-dosing during initiation. Thus, the optimal timing of cardioversion for AF patients undergoing dofetilide initiation to optimize discharge dose remains unknown as does the longitudinal stability of QTc . The purpose of this study was to evaluate the impact of baseline rhythm on dofetilide dosing during initiation and assess the longitudinal stability of QTc-all (Bazzett, Fridericia, Framingham, and Hodges) over time. METHODS: Medical records of patients who underwent preplanned dofetilide loading at a tertiary care center between January 2016 and 2019 were reviewed. RESULTS: A total of 198 patients (66 ± 10 years, 32% female, CHADS2 -Vasc 3 [2-4]) presented for dofetilide loading in either AF (59%) or sinus rhythm (SR) (41%). Neither presenting rhythm, nor spontaneous conversion to SR impacted discharge dose. The cumulative dofetilide dose before cardioversion moderately correlated (r = .36; p = .0001) with discharge dose. Postcardioversion QTc-all prolongation (p < .0001) prompted discharge dose reduction (890 ± 224 mcg vs. 552 ± 199 mcg; p < .0001) in 30% patients. QTc-all in SR prolonged significantly during loading (p < .0001). All patients displayed QTc-all reduction (p < .0001) from discharge to short-term (46 [34-65] days) that continued at long-term (360 [296-414] days) follow-ups. The extent of QTc-all reduction over time moderately correlated with discharge QTc-all (r = .54-0.65; p < .0001). CONCLUSION: Dofetilide initiation before cardioversion is equivalent to initiation during SR. Significant QTc reduction proportional to discharge QTc is seen over time in all dofetilide-treated patients. QTc returns to preloading baseline during follow-up in patients initiated in SR.


Assuntos
Fibrilação Atrial , Síndrome do QT Longo , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/induzido quimicamente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Feminino , Humanos , Síndrome do QT Longo/induzido quimicamente , Masculino , Alta do Paciente , Fenetilaminas/efeitos adversos , Estudos Retrospectivos , Sulfonamidas
2.
Heart Rhythm ; 19(2): 197-205, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34666139

RESUMO

BACKGROUND: The STOP AF First trial recently demonstrated that initial treatment with cryoballoon ablation (CBA) is safe and superior to antiarrhythmic drug (AAD) therapy for preventing atrial arrhythmia recurrence in patients with symptomatic atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to evaluate the change in quality of life (QoL) and symptoms after first-line CBA vs AAD therapy. METHODS: Patients with symptomatic AF not previously receiving rhythm control therapy were randomized to AAD (class I or III) or CBA (Arctic Front Advance, Medtronic, Mounds View, MN). QoL was evaluated at baseline and at 6 and 12 months by using the Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT) and the European Quality of Life-5 Dimensions questionnaires. A review of AF-associated symptoms was conducted at baseline and at 1, 3, 6, and 12 months. RESULTS: In total, 203 subjects received either CBA (n = 104 [51.2%]) or AAD therapy (n = 99 [48.8%]). Improvements in the AFEQT summary and subscale scores were significantly larger with CBA than with AAD therapy at 6 and 12 months (P < .02 for all). Clinically meaningful improvement (>5 points) in the AFEQT summary score from baseline to 12 months was observed in 96.0% (100) of patients in the CBA arm vs 72.2% (71) of patients in the AAD arm (P < .001). No significant between-group differences were observed in the change in the European Quality of Life-5 Dimensions index or visual analog scale scores. Overall, 54.4% (57) of the CBA group vs 29.7% (29) of the AAD group reported no AF-specific symptom recurrence after a 90-day blanking period (P = .0005). CONCLUSION: First-line CBA vs AAD therapy is associated with larger improvements in AF-specific QoL and a higher rate of symptom resolution.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Criocirurgia , Qualidade de Vida , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Heart Rhythm O2 ; 3(6Part A): 639-646, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589916

RESUMO

Background: Outcomes following catheter ablation (CA) for atrial fibrillation (AF) improve as the diagnosis-to-ablation time (DAT) shortens. Use of a protocol-based integrated care model through a dedicated atrial fibrillation clinic (AFC) may serve to standardize treatment pathways and decrease DAT. Objective: To evaluate the DAT and clinical characteristics of patients with AF referred from an AFC vs a conventional electrophysiology clinic (EC). Methods: Retrospective analysis was completed in consecutive patients undergoing index AF ablation at Riverside Methodist Hospital in 2019 with minimum 1 year follow-up. Patients were categorized based off their CA referral source (AFC vs EC) and where the initial visit following index diagnosis of AF occurred (AFC vs EC). Results: A total of 182 patients (mean age 65 years, 64% male) were reviewed. Patients referred from an AFC (21%) had a median DAT of 342 days (interquartile range [IQR], 125-855 days) compared to patients referred from EC (79%) with a median DAT of 813 days (IQR, 241-1444 days; P = .01). Patients with their index visit following AF diagnosis occurring in the AFC (9%) had significantly shorter median DAT (127 days [IQR, 95-188 days]) compared to EC (91%) (789 days [IQR, 253-1503 days]; P = .002). Patients with DAT <1 year had lower AF recurrence than patients with DAT >1 year (P = .04, hazard ratio = 0.58, 95% confidence interval 0.3418-1.000). Conclusion: DAT is a modifiable factor that may affect CA outcomes. Significant reductions in DAT were observed in patients evaluated through a dedicated AF clinic.

4.
N Engl J Med ; 384(4): 316-324, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197158

RESUMO

BACKGROUND: In patients with symptomatic paroxysmal atrial fibrillation that has not responded to medication, catheter ablation is more effective than antiarrhythmic drug therapy for maintaining sinus rhythm. However, the safety and efficacy of cryoballoon ablation as initial first-line therapy have not been established. METHODS: We performed a multicenter trial in which patients 18 to 80 years of age who had paroxysmal atrial fibrillation for which they had not previously received rhythm-control therapy were randomly assigned (1:1) to receive treatment with antiarrhythmic drugs (class I or III agents) or pulmonary vein isolation with a cryoballoon. Arrhythmia monitoring included 12-lead electrocardiography conducted at baseline and at 1, 3, 6, and 12 months; patient-activated telephone monitoring conducted weekly and when symptoms were present during months 3 through 12; and 24-hour ambulatory monitoring conducted at 6 and 12 months. The primary efficacy end point was treatment success (defined as freedom from initial failure of the procedure or atrial arrhythmia recurrence after a 90-day blanking period to allow recovery from the procedure or drug dose adjustment, evaluated in a Kaplan-Meier analysis). The primary safety end point was assessed in the ablation group only and was a composite of several procedure-related and cryoballoon system-related serious adverse events. RESULTS: Of the 203 participants who underwent randomization and received treatment, 104 underwent ablation, and 99 initially received drug therapy. In the ablation group, initial success of the procedure was achieved in 97% of patients. The Kaplan-Meier estimate of the percentage of patients with treatment success at 12 months was 74.6% (95% confidence interval [CI], 65.0 to 82.0) in the ablation group and 45.0% (95% CI, 34.6 to 54.7) in the drug-therapy group (P<0.001 by log-rank test). Two primary safety end-point events occurred in the ablation group (Kaplan-Meier estimate of the percentage of patients with an event within 12 months, 1.9%; 95% CI, 0.5 to 7.5). CONCLUSIONS: Cryoballoon ablation as initial therapy was superior to drug therapy for the prevention of atrial arrhythmia recurrence in patients with paroxysmal atrial fibrillation. Serious procedure-related adverse events were uncommon. (Supported by Medtronic; STOP AF First ClinicalTrials.gov number, NCT03118518.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/administração & dosagem , Antiarrítmicos/efeitos adversos , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Prevenção Secundária/métodos , Método Simples-Cego , Inquéritos e Questionários
5.
J Atr Fibrillation ; 12(6): 2242, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33024484

RESUMO

BACKGROUND: Catheter ablation (CA) is an established treatment for patients with symptomatic atrial fibrillation (AF). The purpose of this study was to evaluate the safety and efficacy of single CA in AF patients with extreme obesity (body mass index [BMI] ≥ 40 kg/m2) and its long-term impact on body weight. METHODS: Patients with BMI ≥40 kg/m2 who underwent CA at the Ohio State University between 2012 and 2016 were included. The primary efficacy endpoint was no atrial arrhythmia lasting > 30 seconds without anti-arrhythmic drugs during 1-year follow-up after a single procedure. RESULTS: Out of 230 AF patients with BMI ≥ 40 kg/m2 undergoing CA, pulmonary vein isolation was achieved in 226 (98%) patients.Seventeen patients (7.4%) experienced acute major complications, including pericardial effusion, vascular complications and respiratory failure. Patient characteristics for 135 patients with complete 1-year follow-up were as follows: mean age 58.6 ± 9.6 years, mean BMI 44.5±4.7 kg/m2, female 63 (47%), non-paroxysmal AF 100 (74%), median CHA2DS2-VASc score 2 (IQR:1-3). In this cohort, the primary efficacy endpoint was achieved in 44 (33%) patients. Paroxysmal AF was associated with higher CA success compared to non-paroxysmal (51 vs. 26% [p < 0.01]).There was no significant weight change even in patients with successful AF CA. CONCLUSIONS: Extreme obesity is associated with low AF CA success, particularly in those with non-paroxysmal AF. Successful AF CA was not associated with long-term weight reduction. A better treatment strategy is needed in this population of AF and extreme obesity.

6.
Heart Rhythm ; 17(1): 75-80, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31323348

RESUMO

BACKGROUND: Implantable loop recorder (ILR) is preferred strategy for prolonged rhythm monitoring. OBJECTIVE: The purpose of this study was to report the incidence and causes of false-positive (FP) diagnoses during remote monitoring with ILR. METHODS: During a 4-week study period, all consecutive remote transmissions in patients with ILR (Reveal LINQ, Medtronic) implanted for atrial fibrillation (AF) surveillance, cryptogenic stroke (CS), and syncope were reviewed. A nurse specializing in device management and an electrophysiologist adjudicated all transmissions. Primary endpoint of the study was incidence of FP in patients with AF, CS, and syncope. RESULTS: A total of 695 remote transmissions (scheduled downloads: 414; Alerts: 281) sent from 559 patients were adjudicated. The majority of patients had ILR for AF surveillance (n = 321), followed by CS (n =168) and syncope (n = 70) with nominal programming for rhythm diagnosis. Incidence of FP transmissions during the study period was 46%, 86%, and 71% in patients with AF, CS, and syncope, respectively. Incidence of FP transmissions was higher in patients with CS and syncope than in patients with AF (P <.001). For scheduled transmissions, primary causes of FP were signal dropout and undersensing; for alert transmissions, primary reasons for FP were premature atrial and ventricular ectopy. CONCLUSION: Incidence of FP during remote monitoring with nominal settings on this ILR was substantial, ranging from 46% to 86% depending on the indication for implantation. Adjudication of these transmissions required a considerable time commitment from electrophysiologists and device clinic personnel but would be required to avoid misdiagnosis and potential errors in clinical management.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Eletrodos Implantados/efeitos adversos , Monitorização Fisiológica/métodos , Idoso , Fibrilação Atrial/diagnóstico , Falha de Equipamento , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico
7.
J Interv Card Electrophysiol ; 57(2): 311-318, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31813098

RESUMO

PURPOSE: To assess the feasibility and safety of same-day discharge after S-ICD implantation by implementing a specific analgesia protocol and phone follow-up. METHODS: Consecutive patients presenting for outpatient S-ICD implantation were enrolled between 1/1/2018 and 4/30/2019. An analgesia protocol included pre-operative acetaminophen and oxycodone, intraoperative local bupivacaine, and limited use of oxycodone-acetaminophen at discharge. The primary outcome was successful same-day discharge. Numerical Pain Rating Scale (NPRS) on postoperative day (POD) 1, 3, 14, and 30 and any unplanned health care visits during the 1-month follow-up period were assessed. RESULTS: Out of 53 potentially eligible S-ICD patients, 49 patients (92.5%) were enrolled and successfully discharged on the same day. Mean age of these 49 patients was 47 ± 14 years. There were no acute procedural complications. Severe pain (NPRS ≥ 8) on POD 0, 1, and 3 was present in 14.3%, 14.3%, and 8.2% of patients, respectively. The total in-hospital stay was 534 ± 80 min. Four unplanned visits (8%) due to cardiac or device-related issues occurred during 1-month follow-up, including 2 patients with heart failure exacerbation, one patient with an incisional infection, and one patient with inappropriate shocks. CONCLUSIONS: With the appropriate institutional protocol including specific analgesics and phone follow-up, same-day discharge after outpatient S-ICD implantation is feasible and appears safe for most patients.. Device-related pain can be severe in the first 3 days post-implantation and can be successfully treated with limited supply of narcotic medications.


Assuntos
Analgesia/métodos , Desfibriladores Implantáveis , Segurança do Paciente , Implantação de Prótese/métodos , Idoso , Continuidade da Assistência ao Paciente , Estudos de Viabilidade , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Manejo da Dor , Medição da Dor
8.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31702059

RESUMO

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Assuntos
Anestesia/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Anestesia Geral , Anestesia Local , Bradicardia/tratamento farmacológico , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipotensão/tratamento farmacológico , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
9.
J Cardiovasc Electrophysiol ; 30(11): 2453-2459, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502324

RESUMO

BACKGROUND: An internal risk stratification algorithm was developed to decrease the risk of major adverse cardiac events (MACEs) during lead extractions (LEs). OBJECTIVE: To report upon the impact of a risk stratification algorithm (RISE [RIsk Stratification prior to lead Extraction] protocol) on outcomes of LEs in a high-volume center. METHODS: A retrospective review of a prospectively maintained LEs database was performed to identify features associated with MACEs. On the basis of the retrospective data, the RISE protocol differentiated LEs procedures into "High" and "Low" risk for occurrence of MACEs. High-risk LEs included dual-coil defibrillator lead (≥3 years), pacemaker and single-coil lead (≥5 years), and any StarFix coronary sinus lead. During the prospective evaluation of the RISE protocol, "High-risk" LEs were performed in an operating room (OR) or hybrid laboratory with the cardiac anesthesiologist, OR nursing team, perfusionist in the room, and a cardiac surgeon on the premises. "Low-risk" LEs were performed in the electrophysiology (EP) laboratory with anesthesia provided by EP nursing team. The preintervention (pre-RISE) and postintervention (post-RISE) group spanned 19 and 40 months and consisted of 449 (632 leads) and 751 patients (1055 leads), respectively. The primary outcome of MACEs in the two groups was compared. RESULTS: Protocol compliance was 100%. The primary outcome of MACEs occurred in 15 patients (3.34%) before and 12 (1.6%) after implementation of the RISE protocol (P = .04). CONCLUSION: RISE identified a low-risk group where minimal resources are needed and allowed for rapid intervention in the high-risk group that reduced the consequences of MACEs.


Assuntos
Protocolos Clínicos , Desfibriladores Implantáveis , Remoção de Dispositivo/efeitos adversos , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/mortalidade , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Desenho de Prótese , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Pacing Clin Electrophysiol ; 42(1): 58-62, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30414285

RESUMO

BACKGROUND: Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD. METHODS: The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted. RESULTS: There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD. CONCLUSION: Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Falha de Equipamento , Complicações Pós-Operatórias/prevenção & controle , Idoso , Eletrocardiografia , Feminino , Fluoroscopia , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco
11.
Pacing Clin Electrophysiol ; 41(11): 1491-1494, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30191582

RESUMO

BACKGROUND: A wearable cardioverter defibrillator (WCD) is an alternative for patients who are not immediate candidates for an implantable cardioverter defibrillator (ICD). METHODS: Retrospective analysis of 242 patients prescribed a WCD from January 2014 through March 2015 with 1-year follow-up. RESULTS: A WCD was prescribed to 242 patients during the 15-month period. Forty-one patients were excluded due to lack of complete follow-up. The remaining 201 patients received a WCD for primary or secondary prevention of SCD. Seventy-nine percent of WCDs were prescribed by nonelectrophysiologists. Underlying etiologies for the WCD prescription included: 38% nonischemic cardiomyopathy, 25% recent myocardial infarction, 16% newly diagnosed ischemic cardiomyopathy, 12% documented ventricular arrhythmia, 6% ICD lead extraction, and 3% had high risk conditions for sudden cardiac death. During 1-year follow-up, 96 patients (48%) received an ICD and five patients (2.5%) received appropriate shocks and one patient (0.5 %) received an inappropriate shock. Other 105 (52%) patients subsequently did not require an ICD due to either improvement in ejection fraction, refusal of ICD therapy, or death. CONCLUSIONS: About half of patients prescribed a WCD subsequently receive an ICD and the rate of appropriate shock therapy from the WCD is 2.5%.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 29(10): 1460-1466, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29964312

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infections associated with large, mobile vegetation adds to the complexity of lead extraction and is associated with significant patient morbidity and mortality. OBJECTIVE: To show the feasibility of concomitant cardiovascular implantable electronic device extraction and vacuum-assisted removal of lead-related vegetations. METHODS: This is a single-center retrospective case series of consecutive patients with persistent bacteremia, sepsis, or endocarditis despite medical therapy who have vegetations >2 cm and subsequently underwent immediate CIED lead extraction after debulking with vacuum-assisted suction. RESULTS: Eight patients underwent successful removal of 17 leads immediately after debulking of vegetations with vacuum-assisted device suction. Debulking procedure was not successful in 1 patient due to inability to direct the vacuum suction device into proper position. There were no intraprocedure complications related to the vacuum-assisted debulking. One patient required open sternotomy for tear of the coronary sinus ostium related to extraction of a left ventricular pacing electrode. There was no mortality within 30 days of the procedure. CONCLUSIONS: Based upon these clinical results, it is feasible for patients with infected CIED systems that have large right-sided vegetations to undergo vacuum-assisted debulking then immediately followed by percutaneous CIED removal in whom surgical removal is considered high risk.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos de Citorredução/métodos , Remoção de Dispositivo/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/terapia , Adulto , Idoso , Procedimentos Cirúrgicos de Citorredução/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sucção , Resultado do Tratamento , Vácuo , Adulto Jovem
13.
Heart Rhythm ; 15(4): 520-523, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29146276

RESUMO

BACKGROUND: The perioperative anticoagulation management during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: The purpose of this study was to assess whether it is safe to perform S-ICD implantation with uninterrupted warfarin. METHODS: This is a single-center retrospective review of patients undergoing S-ICD implantation between October 1, 2012 and June 30, 2017. One hundred thirty-seven patients underwent successful S-ICD implantation during the study period. The most common indication for implantation was primary prevention of sudden cardiac death. In 24 (17.5%) patients, warfarin was continued without any interruption (warfarin group). In 113 (82.5%) patients, no warfarin was used in the perioperative period (nonwarfarin group). The incidence of clinically significant lateral pocket hematoma was compared in the 2 groups. RESULTS: The mean international normalized ratio was 1.83 ± 0.47 in the warfarin group and 1.09 ± 0.18 in the nonwarfarin group. A total of 8 patients developed a hematoma at the lateral pocket. No patient developed a hematoma at the parasternal pockets. Six patients (25%) in the warfarin group and 2 (1.5%) in the nonwarfarin group developed a significant lateral pocket hematoma (P = .001). The mean length of stay was longer in the warfarin group (1.23 ± 0.46 days) than in the nonwarfarin group (1.02 ± 0.18 days) (P = .0008). An international normalized ratio of >1.8 predicted the risk of hematoma. The concomitant use of dual antiplatelet therapy did not increase the risk of hematoma. None of the patients with a hematoma developed infection or required hematoma evacuation. CONCLUSION: Uninterrupted warfarin in the perioperative period during S-ICD implantation is associated with an increased risk of significant lateral pocket hematoma that results in prolonged hospital stay.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Assistência Perioperatória/métodos , Prevenção Primária/métodos , Implantação de Prótese/métodos , Varfarina/administração & dosagem , Administração Oral , Anticoagulantes/administração & dosagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Indian Pacing Electrophysiol J ; 18(2): 68-72, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29225010

RESUMO

BACKGROUND: Expert opinion recommends performing exercise testing with initiation of Class Ic antiarrhythmic medication. OBJECTIVE: To evaluate the rate and reason for discontinuation of Ic agent within the first year of follow up, with particular attention to rate of proarrhythmia and the value of routine treadmill testing. METHODS: This is a single center retrospective cohort study including consecutive patients with atrial arrhythmias who were initiated on a Class Ic agent from 2011 to 2016. Data was collated from chart review and pharmacy database. RESULTS: The study population included 300 patients (55% male, mean age 61; mean ejection fraction, 56%) started on flecainide (n = 153; 51%) and propafenone (n = 147; 49%). Drug initiation was completed while hospitalized on telemetry and the staff electrophysiologists directed dosing. There was one proarrhythmic event during initiation (0.3%). The primary reason for not being discharged on Ic agent was due to detection of proarrhythmia (n = 15) or ischemia (n = 1) with treadmill testing (5.3%). Exercise testing was the single significant variable to affect the decision to discontinue Ic drug, p < 0.0001 (95% CI: 1.89-6.08%). During follow up, the primary reason for discontinuation of Ic agent was lack of efficacy, 32%. CONCLUSIONS: With proper screening, initiation of Class Ic agent is associated with very low rate of proarrhythmia. Treadmill testing is of incremental value and should be completed in all patients after loading Class Ic antiarrhythmic.

16.
Heart Rhythm ; 14(10): 1436-1439, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28624663

RESUMO

BACKGROUND: During early experience with subcutaneous implantable cardioverter-defibrillators (S-ICD), several patients had inappropriate shocks from T-wave oversensing (TWOS) during exercise. This prompted some operators to perform routine treadmill exercise tests after implantation of S-ICD to screen for TWOS. Meanwhile, improvements have been made in the detection algorithms by the manufacturer. OBJECTIVE: To assess whether routine treadmill exercise post S-ICD implantation is warranted. METHODS: Patients undergoing S-ICD implantation from October 2012 to December 2016 who were able to complete a treadmill exercise were included in the study. The amplitude of R and T waves as assessed by the device programmer at rest and peak exercise was calculated and incidence of TWOS recorded. RESULTS: Eighty-seven patients with complete treadmill exercise test data were included in the final analysis. The majority of the patients received S-ICD for primary prevention. Nine percent of the included patients had hypertrophic obstructive cardiomyopathy. During treadmill exercise, there was significant increase in the heart rate from rest (77 ± 14 beats per minute) to peak exercise (133 ± 14 beats per minute; P < .0001). There was no significant difference between R-wave amplitude at rest (2 ± 0.77 mV) and peak exercise (1.88 ± 0.94 mV; P = .36). Similarly, there was no significant difference between T-wave amplitude at rest (0.27 ± 0.19 mV) and peak exercise (0.33 ± 0.23 mV; P = .06). The incidence of TWOS during exercise was zero. CONCLUSIONS: With current screening and detection algorithms for S-ICD, routine treadmill exercise does not result in additional discrimination of patients susceptible to TWOS.


Assuntos
Algoritmos , Arritmias Cardíacas/prevenção & controle , Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Eletrocardiografia , Teste de Esforço/métodos , Prevenção Primária/métodos , Adulto , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos
18.
J Clin Anesth ; 31: 53-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27185678

RESUMO

BACKGROUND: The recently approved subcutaneous implantable cardioverter/defibrillator (S-ICD) uses a single extrathoracic subcutaneous lead to treat life-threatening ventricular arrhythmias, such as ventricular tachycardia and ventricular fibrillation. This is different from conventional transvenous ICDs, which are typically implanted under sedation. Currently, there are no reports regarding the anesthetic management of patients undergoing S-ICD implantation. STUDY OBJECTIVES: This study describes the anesthetic management and outcomes in patients undergoing S-ICD implantation and defibrillation threshold (DFT) testing. METHODS: The study population consists of 73 patients who underwent S-ICD implantation. General anesthesia (n = 69, 95%) or conscious/deep sedation (n = 4, 5%) was used for device implantation. MEASUREMENTS: Systolic blood pressure (SBP) and heart rate were recorded periprocedurally for S-ICD implantation and DFTs. Major adverse events were SBP <90 mm Hg refractory to vasopressor agents, significant bradycardia (heart rate <45 beats per minute) requiring pharmacologic intervention and, "severe" pain at the lead tunneling site and the S-ICD generator insertion site based on patient perception. INTERVENTIONS: Of the 73 patients, 39 had SBP <90 mm Hg (53%), and intermittent boluses of vasopressors and inotropes were administered with recovery of SBP. In 2 patients, SBP did not respond, and the patients required vasopressor infusion in the intensive care unit. MAIN RESULTS: Although the S-ICD procedure involved extensive tunneling and a mean of 2.5 ± 1.7 DFTs per patient, refractory hypotension was a major adverse event in only 2 patients. The mean baseline SBP was 132.5 ± 22.0 mm Hg, and the mean minimum SBP during the procedure was 97.3 ± 9.2 mm Hg (P < .01). There was also a mean 13-beats per minute decrease in heart rate (P < .01), but no pharmacologic intervention was required. Eight patients developed "severe" pain at the lead tunneling and generator insertion sites and were adequately managed with intravenous morphine. CONCLUSIONS: Among a heterogeneous population, anesthesiologists can safely manage patients undergoing S-ICD implantation and repeated DFTs without wide swings in SBP and with minimal intermittent pharmacologic support.


Assuntos
Anestesia Geral/métodos , Arritmias Cardíacas/terapia , Sedação Consciente/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Pressão Sanguínea/fisiologia , Bradicardia/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Hipotensão/etiologia , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos
19.
Avicenna J Med ; 6(1): 8-16, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26955600

RESUMO

Atrial fibrillation (AF) is the most commonly encountered arrhythmia in clinical practice. Aging populations coupled with improved outcomes for many chronic medical conditions has led to increases in AF diagnoses. AF is also known to be associated with an increased risk of adverse events such as transient ischemic attack, ischemic stroke, systemic embolism, and death. This association is enhanced in select populations with preexisting comorbid conditions such as chronic heart failure. The aim of this review is to highlight the advances in the field of cardiology in the management of AF in both acute and long-term settings. We will also review the evolution of anticoagulation management over the past few years and landmark trials in the development of novel oral anticoagulants (NOACs), reversal agents for new NOACs, nonpharmacological options to anticoagulation therapy, and the role of implantable loop recorder in AF management.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA