Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 87(2): 1018-25, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25495653

RESUMO

This manuscript reports a new pesticide residue analysis method employing a microflow-liquid chromatography system coupled to a triple quadrupole mass spectrometer (microflow-LC-ESI-QqQ-MS). This uses an electrospray ionization source with a narrow tip emitter to generate smaller droplets. A validation study was undertaken to establish performance characteristics for this new approach on 90 pesticide residues, including their degradation products, in three commodities (tomato, pepper, and orange). The significant benefits of the microflow-LC-MS/MS-based method were a high sensitivity gain and a notable reduction in matrix effects delivered by a dilution of the sample (up to 30-fold); this is as a result of competition reduction between the matrix compounds and analytes for charge during ionization. Overall robustness and a capability to withstand long analytical runs using the microflow-LC-MS system have been demonstrated (for 100 consecutive injections without any maintenance being required). Quality controls based on the results of internal standards added at the samples' extraction, dilution, and injection steps were also satisfactory. The LOQ values were mostly 5 µg kg(-1) for almost all pesticide residues. Other benefits were a substantial reduction in solvent usage and waste disposal as well as a decrease in the run-time. The method was successfully applied in the routine analysis of 50 fruit and vegetable samples labeled as organically produced.


Assuntos
Cromatografia Líquida/métodos , Resíduos de Praguicidas/análise , Extração em Fase Sólida/métodos , Solventes/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Capsicum/química , Citrus sinensis/química , Solanum lycopersicum/química , Sensibilidade e Especificidade
2.
J Sep Sci ; 37(12): 1511-20, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24687968

RESUMO

An analytical method for determining phenylureas (monuron, isoproturon, diuron, linuron and neburon) and propanil herbicides in wastewater has been developed and validated, and the most significant parameters were compared with the corresponding ones found in the literature, thus showing the method performance. The method involves pre-concentration by a simple, rapid, sensitive and low environmental toxicity temperature-controlled ionic liquid dispersive liquid-liquid microextraction procedure. The herbicides were identified and determined by liquid chromatography with a hybrid triple quadrupole linear ion trap mass spectrometer. Data acquisition in selected-reaction monitoring mode allowed the simultaneous identification and quantification of the analytes using two transitions. The information dependent acquisition scan was performed to carry out the identification of those analytes whose second transition was present at low intensity, also providing extra confirmation for the other analytes. Limits of quantification were in the range 1.0-5.0 ng/L. Good recoveries (95-103%) were obtained for the extraction of the target analytes in wastewater samples. The methodology developed was applied to analyze effluent wastewater samples from a wastewater treatment plant located in an agricultural zone of Almería (Spain) and the results indicated the presence of diuron at mean concentration levels of 73.5 ng/L.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Herbicidas/isolamento & purificação , Microextração em Fase Líquida/métodos , Espectrometria de Massas/métodos , Águas Residuárias/química , Poluentes Químicos da Água/isolamento & purificação , Herbicidas/análise , Espanha , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA