Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Front Physiol ; 13: 857538, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35530511

RESUMO

The ANTHEM-HF, INOVATE-HF, and NECTAR-HF clinical studies of autonomic regulation therapy (ART) using vagus nerve stimulation (VNS) systems have collectively provided dose-ranging information enabling the development of several working hypotheses on how stimulation frequency can be utilized during VNS for tolerability and improving cardiovascular outcomes in patients living with heart failure (HF) and reduced ejection fraction (HFrEF). Changes in heart rate dynamics, comprising reduced heart rate (HR) and increased HR variability, are a biomarker of autonomic nerve system engagement and cardiac control, and appear to be sensitive to VNS that is delivered using a stimulation frequency that is similar to the natural operating frequency of the vagus nerve. Among prior studies, the ANTHEM-HF Pilot Study has provided the clearest evidence of autonomic engagement with VNS that was delivered using a stimulation frequency that was within the operating range of the vagus nerve. Achieving autonomic engagement was accompanied by improvement from baseline in six-minute walk duration (6MWD), health-related quality of life, and left ventricular EF (LVEF), over and above those achieved by concomitant guideline-directed medical therapy (GDMT) administered to counteract harmful neurohormonal activation, with relative freedom from deleterious effects. Autonomic engagement and positive directional changes have persisted over time, and an exploratory analysis suggests that improvement in autonomic tone, symptoms, and physical capacity may be independent of baseline NT-proBNP values. Based upon these encouraging observations, prospective, randomized controlled trials examining the effects on symptoms and cardiac function as well as natural history have been warranted. A multi-national, large-scale, randomized, controlled trial is well underway to determine the outcomes associated with ART using autonomic nervous system engagement as a guide for VNS delivery.

2.
ESC Heart Fail ; 7(1): 75-83, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31984682

RESUMO

AIMS: Clinical studies of vagal nerve stimulation (VNS) for heart failure with reduced ejection fraction have had mixed results to date. We sought to compare VNS delivery and associated changes in symptoms and function in autonomic regulation therapy via left or right cervical vagus nerve stimulation in patients with chronic heart failure (ANTHEM-HF), increase of vagal tone in heart failure (INOVATE-HF), and neural cardiac therapy for heart failure (NECTAR-HF) for hypothesis generation. METHODS AND RESULTS: Descriptive statistics were used to analyse data from the public domain for differences in proportions using Pearson's chi-square test, differences in mean values using Student's unpaired t-test, and differences in changes of mean values using two-sample t-tests. Guideline-directed medical therapy recommendations were similar across studies. Fewer patients were in New York Heart Association 3, and baseline heart rate (HR) was higher in ANTHEM-HF. In INOVATE-HF, VNS was aimed at peripheral neural targets, using closed-loop delivery that required synchronization of VNS to R-wave sensing by an intracardiac lead. Pulse frequency was low (1-2 Hz) because of a timing schedule allowing ≤3 pulses of VNS following at most 25% of detected R waves. NECTAR-HF and ANTHEM-HF used open-loop VNS delivery (i.e. independent of any external signal) aimed at both central and peripheral targets. In NECTAR-HF, VNS delivery at 20 Hz caused off-target effects that limited VNS up-titration in a majority of patients. In ANTHEM-HF, VNS delivery at 10 Hz allowed up-titration until changes in HR dynamics were confirmed. Six months after VNS titration, significant improvements in both HR and HR variability occurred only in ANTHEM-HF. When ANTHEM-HF and NECTAR-HF were compared, greater improvements from baseline were observed in ANTHEM-HF in standard deviation in normal-to-normal R-R intervals (94 ± 26 to 111 ± 50 vs. 146 ± 48 to 130 ± 52 ms; P < 0.001), left ventricular ejection fraction (32 ± 7 to 37 ± 0.4 vs. 31 ± 6 to 33 ± 6; P < 0.05), and Minnesota Living with Heart Failure mean score (40 ± 14 to 21 ± 10 vs. 44 ± 22 to 36 ± 21; P < 0.002). When compared with INOVATE-HF, greater improvement in 6-min walk distance was observed in ANTHEM-HF (287 ± 66 to 346 ± 78 vs. 304 ± 111 to 334 ± 111 m; P < 0.04). CONCLUSIONS: In this post-hoc analysis, differences in patient demographics were seen and may have caused the differential responses in symptoms and function observed in association with VNS. Major differences in technology platforms, neural targets, VNS delivery, and HR and HR variability responses could have also potentially played a very important role. Further study is underway in a randomized controlled trial with these considerations in mind.


Assuntos
Insuficiência Cardíaca , Estimulação do Nervo Vago , Idoso , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Néctar de Plantas , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA