Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Mass Spectrom ; 56(2): e4695, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33410206

RESUMO

Despite the increasing detection of emerging substances in the environment, the identity of most are left unknown due to the lack of efficient identification methods. We developed a non-target analysis method for identifying unknown substances in the environment by liquid chromatography/high-resolution mass spectrometry (LC/HRMS) with a product ion and neutral loss database (PNDB). The present analysis describes an elucidation method with elemental compositions of the molecules, product ions, and corresponding neutral losses of the unknown substance: (1) with the molecular formula, possible molecular structures are retrieved from two chemical structure databases (PubChem and ChemSpider); then (2) with the elemental compositions of product ions and neutral losses, possible partial structures are retrieved from the PNDB; and finally, (3) molecular structures that match the possible partial structures are listed in order of number of hits. A molecular structure with a higher number of hits is more similar to the structure of the analyzed substance. The performance of the non-target method was evaluated by simulated analysis of 150 LC/HRMS spectra registered in MassBank. First, all substances of the same mass data (41/41) and 68% (39/57) of the mass data of the same substances not registered in the PNDB were elucidated. It was demonstrated that 14% (7/52) and 31% (16/52) of the substances with no mass spectral data registered in the PNDB were obtained at the first and within the fifth place, respectively. Owing to the fact that 10 of the total hits occurred in product ions and neutral losses, almost 50% of the substances evaluated with this method were placed at the top 4 positions in the similarity ranking. Importantly, the proposed method is effective for analyzing mass spectral data that has not been registered in the PNDB and thus is expected to be used for a variety of non-target analyses.

2.
Anal Sci ; 20(10): 1459-62, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15524202

RESUMO

A sensitive liquid chromatograph/tandem mass spectrometric technique (LC/MS/MS) was applied to determine aliphatic and aromatic carbonyl compounds in ambient air. Traces of the carbonyl compounds were sampled by passing through a Sep-Pak DNPH-silica cartridge. Their derivatives were thus eluted with acetonitrile, separated by reversed-phase liquid chromatography and determined by quadrupole tandem mass spectrometry in an atmospheric pressure chemical ionization (APCI) mode with multiple reaction monitoring (MRM). The detection limits (DL) of the carbonyl compounds were 0.8 - 15 ng/m3. A number of the carbonyl compounds were detected at n.d.- 14 microg/m3 levels. The precursor ion scanning analysis was applied to identify the unknown compounds.


Assuntos
Poluentes Atmosféricos/análise , Ar/análise , Aldeídos/análise , Hidrocarbonetos Aromáticos/análise , Cetonas/análise , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA