Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Jpn J Radiol ; 31(3): 220-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23207646

RESUMO

PURPOSE: The aim of this study was to determine to what extent we could identify the metabolism product peak using 3-T proton magnetic resonance spectroscopic imaging (MRSI) of the prostate gland in healthy volunteers by combining an external array coil with Malcolm Levitt composite-pulse decoupling sequence (MLEV)-point-resolved spatially localized spectroscopy (PRESS). MATERIALS AND METHODS: MRSI data were obtained from the entire prostate gland in six healthy volunteers. The heights of the choline, citrate peaks and the standard deviation (SD) of the noise in each voxel were calculated. When the choline and/or citrate peak in a voxel exceeded 3 SD, the peak was clearly identified. RESULTS: The clear citrate peak rate in the peripheral zone (PZ) and the central gland (CG) were 78.8 and 70.3 %, respectively. The clear choline peak rate in the PZ and the CG were 55.4 and 44.9 %, respectively. In addition, the clear peak rates for both citrate and choline in the PZ and the CG were 51.8 and 38.6 %. Therefore, in the entire prostate gland, 75.2 % had a clear citrate peak, 51.1 % had a clear choline peak, and 46.3 % had both citrate and choline peaks. CONCLUSION: The citrate peak was clearly detected in 75.2 % of the voxels by this technique.


Assuntos
Quelantes/metabolismo , Colina/metabolismo , Ácido Cítrico/metabolismo , Lipotrópicos/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Próstata/metabolismo , Biomarcadores/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Próstata/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Magn Reson Med ; 54(5): 1300-4, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16217778

RESUMO

Sentinel lymph node biopsy (SLNB) is an important technique for detecting axillary lymph node metastasis in breast carcinoma patients. However, false-negative results are a problem. Equivalent cross-relaxation rate (ECR) imaging (ECRI) is a measurement method that can be used to quantitatively evaluate a change in the structural organization of lymph nodes by magnetic resonance imaging (MRI). We performed axillary ECRI in an attempt to decrease the false-negative results of SLNB. Regions without metastases showed a higher ECR value. On the other hand, regions with metastases showed a lower ECR value. The ECR images were compared with macroscopic histology images in which the presence or absence of axillary lymph node metastasis could be evaluated. ECRI is a potentially useful method for evaluating the efficacy of SLNB.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal/patologia , Carcinoma Ductal/secundário , Interpretação de Imagem Assistida por Computador/métodos , Linfonodos/patologia , Imageamento por Ressonância Magnética/métodos , Biópsia de Linfonodo Sentinela/métodos , Adulto , Idoso , Algoritmos , Reações Falso-Negativas , Feminino , Humanos , Aumento da Imagem/métodos , Metástase Linfática , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 61(1): 118-25, 2005 Jan 20.
Artigo em Japonês | MEDLINE | ID: mdl-15682040

RESUMO

We evaluated the usefulness of two-dimensional time-of-flight (2D TOF) MR venography (MRV) of the lower extremity using the respiratory compensation (RC) technique. In addition, six variations in patient positioning of the leg and knee were investigated to determine the best method of visualizing the deep popliteal veins and lower leg. All data sets were reviewed and graded for visualization of the deep veins at the pelvis, thigh, and leg portion (4-point scale) by two radiologists and three radiological technologists. The same veins demonstrated with various positions of the patient were also evaluated in the same manner. In conclusion, 2D TOF MRV with RC resulted in increased uniformity of vein signal in the pelvic area. Furthermore, we should position the patient's leg so as not to compress the vein at the posterior portion of the leg, and not to over-extend the knee joint. This enabled the best results to be obtained in MRV of the lower extremity.


Assuntos
Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Postura , Adulto , Humanos , Pessoa de Meia-Idade , Veia Poplítea/diagnóstico por imagem , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA