Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nucl Med Commun ; 38(4): 285-290, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28244975

RESUMO

PURPOSE: The aim of this study was to evaluate the utility of Tc-ubiquicidin (Tc-UBI) (29-41) as an adjunct to an methylene diphosphonate (MDP) bone scan in differentiating septic versus aseptic loosening in patients with painful prosthesis posted for revision surgery. PATIENTS AND METHODS: A two-vial cold kit of UBI (29-41) was prepared and utilized for the preparation of patient dose of Tc-UBI (29-41). Twenty two patients with painful hip or knee prosthesis and scheduled for revision surgery were included in the study. Overall, 370-555 MBq of Tc-UBI (29-41) was injected intravenously in all the patients. A blood pool image at 20 min after injection was followed by spot views of the suspected region of infection (target) and a corresponding normal area (nontarget) at 60 min. All patients underwent a routine Tc-MDP three-phase whole-body bone scan, followed by single-photon emission computed tomography/computed tomography of the prosthesis within a week of the Tc-UBI (29-41) study. For Tc-UBI scans, a visual score (0-3) was used to categorize studies as positive or negative, with scores of 0 (minimal or no uptake; less than soft tissue or contralateral extremity) and 1 (mild; equivalent to soft tissue or contralateral extremity) being considered negative and scores of 2 (moderate; uptake greater than soft tissue or contralateral extremity, but less than the liver) or 3 (intense; uptake greater than soft tissue or contralateral extremity and equivalent to the liver) being considered positive. The final correlation was on the basis of bacterial culture as the major criterion and the results of clinical tests, radiography, fluorine-18-fluorodeoxyglucose PET-CT, and three-phase bone scanning as the minor criteria. RESULTS: In all, 22 studies were carried out with Tc-UBI (29-41). Of these, 16 scans were considered positive and six were negative for infection foci. All negative scans were subsequently confirmed to be true negative. Adverse reactions were not observed during image acquisition and within 5 days after the study. The overall sensitivity, specificity, and positive and negative predictive values were 100, 85.7, 93.75, and 100%, respectively. A combination of an MDP bone scan and UBI scans was considered to yield maximum confidence toward reporting for the presence of infection. CONCLUSION: Patient dose of Tc-UBI (29-41) was prepared successfully and a simple quality control method to check radiolabeling yield was used at the hospital radiopharmacy. Tc-UBI (29-41) showed promise in localizing foci of infection, with optimal visualization at 20-60 min, for the evaluation of prosthesis loosening.


Assuntos
Compostos de Organotecnécio , Fragmentos de Peptídeos , Falha de Prótese , Infecções Relacionadas à Prótese/diagnóstico por imagem , Compostos Radiofarmacêuticos , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Prótese de Quadril , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Reoperação , Medronato de Tecnécio Tc 99m
2.
Clin Nucl Med ; 30(9): 630, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16100489

RESUMO

A 49-year-old man with a clinical diagnosis of Graves' disease was referred for a thyroid scan and radioactive ablation of the gland. Tc-99m pertechnetate scan revealed a diffuse toxic goiter and radiotracer concentration in the thyroglossal duct. He was given 10 mCi of I-131 orally as treatment of thyrotoxicosis. Repeat scanning of the anterior neck 2 days later revealed concentration of radioiodine in the diffusely enlarged gland and the thyroglossal duct as found on the Tc-99m pertechnetate scan, thus confirming the presence of functioning thyroid tissue in the thyroglossal duct.


Assuntos
Coristoma/diagnóstico por imagem , Doença de Graves/complicações , Glândula Tireoide/anormalidades , Glândula Tireoide/diagnóstico por imagem , Doença de Graves/diagnóstico por imagem , Doença de Graves/radioterapia , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA