Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JMIR Cardio ; 8: e52648, 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39137030

RESUMO

BACKGROUND: For a decade, despite results from many studies, telemedicine systems have suffered from a lack of recommendations for chronic heart failure (CHF) care because of variable study results. Another limitation is the hospital-based architecture of most telemedicine systems. Some systems use an algorithm based on daily weight, transcutaneous oxygen measurement, and heart rate to detect and treat acute heart failure (AHF) in patients with CHF as early on as possible. OBJECTIVE: The aim of this study is to determine the efficacy of a telemonitoring system in detecting clinical destabilization in real-life settings (out-of-hospital management) without generating too many false positive alerts. METHODS: All patients self-monitoring at home using the system after a congestive AHF event treated at a cardiology clinic in France between March 2020 and March 2021 with at least 75% compliance on daily measurements were included retrospectively. New-onset AHF was defined by the presence of at least 1 of the following criteria: transcutaneous oxygen saturation loss, defined as a transcutaneous oxygen measurement under 90%; rise of cardiac frequency above 110 beats per minute; weight gain of at least 2 kg; and symptoms of congestive AHF, described over the phone. An AHF alert was generated when the criteria reached our definition of new-onset acute congestive heart failure (HF). RESULTS: A total of 111 consecutive patients (n=70 men) with a median age of 76.60 (IQR 69.5-83.4) years receiving the telemonitoring system were included. Thirty-nine patients (35.1%) reached the HF warning level, and 28 patients (25%) had confirmed HF destabilization during follow-up. No patient had AHF without being detected by the telemonitoring system. Among incorrect AHF alerts (n=11), 5 patients (45%) had taken inaccurate measurements, 3 patients (27%) had supraventricular arrhythmia, 1 patient (9%) had a pulmonary bacterial infection, and 1 patient (9%) contracted COVID-19. A weight gain of at least 2 kg within 4 days was significantly associated with a correct AHF alert (P=.004), and a heart rate of more than 110 beats per minute was more significantly associated with an incorrect AHF alert (P=.007). CONCLUSIONS: This single-center study highlighted the efficacy of the telemedicine system in detecting and quickly treating cardiac instability complicating the course of CHF by detecting new-onset AHF as well as supraventricular arrhythmia, thus helping cardiologists provide better follow-up to ambulatory patients.

2.
Infection ; 49(5): 999-1006, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34089482

RESUMO

BACKGROUND: Increasing use of cardiovascular implantable electronic devices (CIED), as permanent pacemakers (PPM), implantable cardioverter defibrillators (ICD), or cardiac resynchronization therapy (CRT), is associated with the emergence of CIED-related infective endocarditis (CIED-IE). We aimed to characterize CIED-IE profile, temporal trends, and prognostic factors. METHODS: CIED-IE diagnosed at Rennes University Hospital during years 1992-2017 were identified through computerized database, and included if they presented all of the following: (1) clinical signs of infection; (2) microbiological documentation through blood and/or CIED lead cultures; (3) lead or valve vegetation, or definite IE according to Duke criteria. Data were retrospectively extracted from medical charts. The cohort was categorized in three periods: 1992-1999, 2000-2008, and 2009-2017. RESULTS: We included 199 patients (51 women, 148 men, median age 73 years [interquartile range, 64-79]), with CIED-IE: 158 PPMs (79%), 24 ICD (12%), and 17 CRT (9%). Main pathogens were coagulase-negative staphylococci (CoNS: n = 86, 43%), Staphylococcus aureus (n = 60, 30%), and other Gram-positive cocci (n = 28, 14%). Temporal trends were remarkable for the decline in CoNS (P = 0.002), and the emergence of S. aureus as the primary cause of CIED-IE (24/63 in 2009-2017, 38%). Factors independently associated with one-year mortality were chronic obstructive pulmonary disease (COPD: hazard ratio 3.84 [1.03-6.02], P = 0.03), left-sided endocarditis (HR 2.25 [1.09-4.65], P = 0.03), pathogens other than CoNS (HR 3.16 [1.19-8.39], P = 0.02), and CIED removal/reimplantation (HR 0.41 [0.20-0.83], P = 0.01). CONCLUSIONS: S. aureus has emerged as the primary cause of CIED-IE. Left-sided endocarditis, COPD, pathogens other than CoNS, and no CIED removal/reimplantation are independent risk factors for one-year mortality.


Assuntos
Desfibriladores Implantáveis , Endocardite Bacteriana , Endocardite , Infecções Relacionadas à Prótese , Idoso , Desfibriladores Implantáveis/efeitos adversos , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Feminino , Humanos , Masculino , Infecções Relacionadas à Prótese/epidemiologia , Estudos Retrospectivos , Staphylococcus aureus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA