Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
J Arrhythm ; 40(1): 100-108, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333375

RESUMO

Background: The lesion index (LSI) has been used to estimate lesion formation after radiofrequency catheter ablation. However, the impedance drop and decrease in bipolar amplitude of intracardiac electrograms, which are parameters that are traditionally used to predict effective ablation lesions, are not used to calculate LSI. Therefore, we aimed to investigate the association between LSI and traditional parameters. Methods: We retrospectively investigated 1355 ablation points from 31 patients who underwent LSI-guided pulmonary vein isolation (PVI) using TactiCath. All points were classified into 3 groups based on the impedance drop: (i) <10 Ω (n = 67), (ii) 10-20 Ω (n = 909), and (iii) >20 Ω (n = 379). The LSI targets were 4.5 for the posterior left atrium and 5.2 for the anterior left atrium. After excluding 583 points at which it was difficult to measure the amplitude, 772 ablation points during sinus rhythm were included in the analysis of bipolar amplitude. Results: The target LSI was achieved at 1177 points (86.9%). The median total impedance drop and amplitude just after ablation were 16.0 [13.0-20.0] Ω and 0.21 [0.14-0.30] mV, respectively. There were significant differences among the 3 groups in the impedance and amplitude before ablation, power, target LSI, final LSI, contact force, and interlesion distance. An impedance drop of >10 Ω or an amplitude reduction of >50% was achieved at 95% and 82% of the study points, respectively. There were no major complications at any of the ablation points. Conclusion: LSI-guided PVI seemed to be useful for making sufficient ablation lesions, as assessed by the conventional parameters of impedance and amplitude change.

2.
Quant Imaging Med Surg ; 13(10): 6840-6853, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37869287

RESUMO

Background: Left bundle branch area pacing (LBBAP) has emerged as a novel physiological pacing method to reduce left ventricular (LV) dyssynchrony due to ventricular pacing. Only lumen-less pacing leads (LLLs) with fixed helixes could achieve LBBAP previously, but recently, LBBAP has been performed using stylet-driven leads (SDLs). This study aimed to evaluate the LV dyssynchrony between SDLs and LLLs techniques in LBBAP. Methods: We retrospectively evaluated patients who underwent LBBAP with either SDLs or LLLs. We compared both groups' electrocardiogram (ECG) findings and LV dyssynchrony parameters derived from myocardial perfusion scintigraphy. LV dyssynchrony parameters consisted of phase analysis and regional wall motion analysis. We evaluated bandwidth, phase standard deviation (PSD), and entropy in the phase analysis. The time to the end-systolic frame (TES) was calculated in regional wall motion analysis using single-photon emission computed tomography (SPECT). We also evaluated the maximum differences between segmental TES (MDTES), the standard deviation of TES (SDTES), and the difference in the TES between the lateral wall and septum (DTES-LS). Results: In total, 97 patients were enrolled. The success rate of LBBAP did not differ between the groups [SDLs: 47/48 patients (98%) vs. LLLs: 47/51 patients (92%), P=0.36]. The paced QRS duration and the stimulus to the peak LV activation time (stim-LVAT) also did not differ between SDL and LLL groups (122±10 vs. 119±12 ms, P=0.206; 69±12 vs. 66±13 ms, P=0.31, respectively). There were no differences in bandwidth, PSD, and entropy between SDL and LLL groups (73°±37° vs. 86°±47°, P=0.18; 19°±8.5° vs. 21°±9.7°, P=0.19; 0.57±0.08 vs. 0.59±0.08, P=0.17, respectively). The regional wall motion analysis parameters MDTES, SDTES, and DTES-LS also did not differ between SDL and LLL groups (19%±10% vs. 20%±10%, P=0.885; 5.0%±2.5% vs. 5.0%±2.5%, P=0.995; 5.0%±3.7% vs. 4.8%±4.2%, P=0.78, respectively). Conclusions: LBBAP using SDLs was comparable to LV electrical and mechanical synchrony with LLLs.

3.
Pacing Clin Electrophysiol ; 46(7): 607-614, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37334754

RESUMO

BACKGROUND: Laser balloon-based pulmonary vein isolation (LB-PVI) is available for atrial fibrillation (AF) ablation. The lesion size depends on laser energy; however, the default protocol is not an energy-based setting. We hypothesized that an energy-guided (EG) short-duration protocol may be an alternative to shorten the procedure time without affecting efficacy and safety. METHODS: We evaluated the efficacy and safety of the EG short-duration protocol (EG group) (target energy 120 J/site [12W/10s; 10W/12s; 8.5W/14s; 5.5W/22s]) compared with the default protocol (control group) (12W/20s; 10W/20s; 8.5W/20s; 5.5W/30s). RESULTS: A total of 52 consecutive patients (EG: n = 27 [103veins] and control: n = 25 [91veins]) undergoing LB-PVI (64 ± 10 years, 81% male, 77% paroxysmal) were enrolled. The EG group had a shorter total time in the pulmonary vein (PV) (43.0 ± 13.9 min vs. 61.1 ± 16.0 min, p < .0001), a shorter total laser application time (1348 ± 254 sec vs. 2032 ± 424 sec, p < .0001), and lower total laser energy (12455 ± 2284J vs. 18084 ± 3746J, p < .0001). There was no difference in the total number of laser applications (p = 0269) or first-pass isolation (p = .725). Acute reconduction was identified only in one vein in the EG. No significant differences were observed in the incidence of pinhole rupture (7.4% vs. 4%, p = 1.000) or phrenic nerve palsy (3.7% vs. 12%, p = .341). During a mean follow-up of 13.5 ± 6.1 months, Kaplan-Meier analysis revealed no significant difference in atrial tachyarrhythmia recurrence (p = .227). CONCLUSION: LB-PVI with the EG short-duration protocol may be achieved in a shorter procedure time to avoid deterioration of efficacy and safety. The EG protocol is feasible as a novel point-by-point manual laser-application approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Estudos de Viabilidade , Átrios do Coração , Lasers , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva
4.
J Cardiovasc Dev Dis ; 10(5)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37233171

RESUMO

BACKGROUND: The guideline-recommended low-density lipoprotein cholesterol target level of <70 mg/dL may not be achieved with statin administration in some patients with acute coronary syndrome (ACS). Therefore, the proprotein convertase subtilisin-kexin type 9 (PCSK9) antibody can be added to high-risk patients with ACS. Nevertheless, the optimal duration of PCSK9 antibody administration remains unclear. METHODS AND RESULTS: Patients were randomized to receive either 3 months of lipid lowering therapy (LLT) with the PCSK9 antibody followed by conventional LLT (with-PCSK9-antibody group) or 12 months of conventional LLT alone (without-PCSK9-antibody group). The primary endpoint was the composite of all-cause death, myocardial infarction, stroke, unstable angina, and ischemia-driven revascularization. A total of 124 patients treated with percutaneous coronary intervention (PCI) were randomly assigned to the two groups (n = 62 in each). The primary composite outcome occurred in 9.7% and 14.5% of the patients in the with- and without-PCSK9-antibody groups, respectively (hazard ratio: 0.70; 95% confidence interval: 0.25 to 1.97; p = 0.498). The two groups showed no significant differences in hospitalization for worsening heart failure and adverse events. CONCLUSIONS: In ACS patients who underwent PCI, short-term PCSK9 antibody therapy with conventional LLT was feasible in this pilot clinical trial. Long-term follow-up in a larger scale clinical trial is warranted.

5.
J Cardiovasc Dev Dis ; 10(3)2023 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-36975865

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation is performed under deep sedation, which may cause inspiration-induced negative left atrial pressure (INLAP) associated with deep inspiration. INLAP could be the cause of periprocedural complications. METHODS: We retrospectively enrolled 381 patients with AF (mean age, 63.9 ± 10.8 years; 76 women; 216 cases of paroxysmal AF) who underwent CA under deep sedation using an adaptive servo ventilator (ASV). Patients whose LAP was not obtained were excluded. INLAP was defined as <0 mmHg of mean LAP during inspiration immediately after the transseptal puncture. The primary and secondary endpoints were the presence of INLAP and the incidence of periprocedural complications. RESULTS: Among 381 patients, INLAP was observed in 133 (34.9%). Patients with INLAP had higher CHA2DS2-Vasc scores (2.3 ± 1.5 vs. 2.1 ± 1.6) and 3% oxygen desaturation indexes (median 18.6 (interquartile range 11.2-31.1) vs. 15.7 (8.1-25.3)), and higher prevalence of diabetes mellitus (23.3 vs. 13.3%) than patients without INLAP. Air embolism occurred in four patients with INLAP (3.0 vs. 0.0%). CONCLUSION: INLAP is not rare in patients undergoing CA for AF under deep sedation with ASV. Much attention should be paid to the possibility of air embolism in patients with INLAP.

6.
Europace ; 25(2): 374-381, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36414239

RESUMO

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Nervo Frênico , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
7.
Ann Noninvasive Electrocardiol ; 27(6): e13000, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35972827

RESUMO

INTRODUCTION: Conventional Doppler measurements have limitations in predicting left ventricular diastolic dysfunction (LVDD) in patients with mitral regurgitation (MR). Recently, electrocardiographic P-wave peak time (PWPT) has been proposed as a parameter of detecting LVDD. This study aimed to evaluate the association between PWPT and left ventricular end-diastolic pressure (LVEDP) in patients with MR. METHODS: We performed echocardiography and cardiac catheterization in 82 patients with moderate or severe MR. We classified patients into two groups: low LVEDP group (L-LVEDP) (LVEDP <16 mmHg, n = 40) and high LVEDP group (H-LVEDP) (LVEDP ≥16 mmHg, n = 42). We evaluated LVDD and PWPT based on echocardiographic and electrocardiographic findings in both groups. RESULTS: The PWPT in lead II (PWPTII ) was significantly longer in patients in the H-LVEDP group than in those in the L-LVEDP group (67 vs. 47 ms, p < .001). Using correlation analysis, LVEDP was positively correlated with PWPTII (r = .577, p < .001). Using multivariate analysis, PWPTII was found to be an independent predictor of increased LVEDP (95% CI: 0.1030-0.110; p < .001). Using receiver operating characteristic (ROC) curve analysis, the optimal cutoff value of PWPTII for predicting elevated LVEDP was 58.9 ms, with a sensitivity of 80.0% and a specificity of 73.8% (area under curve: 0.809, 95% CI: 0.713-0.905). CONCLUSION: To the best of our knowledge, this is the first study to assess the effect of a significant valvular disease on PWPT in lead II. These findings suggest that prolonged PWPTII may be an independent predictor of increased LVEDP in patients with moderate or severe MR.


Assuntos
Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Eletrocardiografia , Ecocardiografia , Cateterismo Cardíaco , Análise Multivariada
8.
Open Heart ; 9(2)2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35961693

RESUMO

OBJECTIVE: We sought to investigate whether it is possible to obtain individualised left anterior oblique (LAO) by preprocedural electrocardiographic parameters and, if so, whether these parameters can help to improve the success rate of right ventricular (RV) lead implantation into the interventricular septum. METHODS: In this observational study, we assessed the relationship between preoperative electrocardiographic parameters and the angle of the interventricular septum obtained using thoracic CT. The participants were divided into two groups: a retrospective derivation cohort to derive the optimal formula for the individual septum axis, and a prospective internal validation cohort to which we applied the optimal formula and implanted using the new method. RESULTS: In the retrospective derivation cohort (n=39), the mean angle of individualised LAO assessed by thoracic CT was 53.1°±8.9°, and the preoperative ECG QRS axis was strongly correlated with the interventricular septum axis (R2=0.490). LAO projection derived from the preoperative ECG QRS axis confirmed that the RV lead was placed in the interventricular septum during the pacemaker procedure in the prospective internal validation group (n=30). The success rate for placing the RV lead into the interventricular septum was significantly improved in the internal validation cohort (93% vs 64%, p<0.05). In addition, the N-terminal pro-brain natriuretic peptide level decreased significantly after surgery in the interventricular septal indwelling group. CONCLUSIONS: Individualised LAO angle derived from the preoperative ECG QRS axis is a new useful and simple method for RV lead implantation into the interventricular septum. TRIAL REGISTRATION NUMBER: UMIN000045741.


Assuntos
Septo Interventricular , Eletrocardiografia/métodos , Ventrículos do Coração , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Septo Interventricular/diagnóstico por imagem
9.
J Electrocardiol ; 74: 10-12, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35878533

RESUMO

A 47-year-old man with transmural posterolateral myocardial infarction (MI) and subendocardial inferior MI underwent catheter ablation for monomorphic ventricular tachycardia (VT). Right ventricular extra stimulation could unmask evoked delayed potentials in the subendocardial infarction area without delayed potentials in the sinus rhythm. Extra stimulation mapping for VT is useful for hidden VT substrates, particularly in the subendocardial infarction area.


Assuntos
Eletrocardiografia , Infarto , Humanos , Pessoa de Meia-Idade
10.
J Cardiovasc Electrophysiol ; 33(8): 1826-1836, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748386

RESUMO

INTRODUCTION: Left bundle branch area pacing (LBBAP) has recently been reported to be a new, clinically feasible and safe physiological pacing strategy. The present study aims to investigate the usefulness of LBBAP in reducing mechanical dyssynchrony compared with right ventricular septal pacing (RVSP). METHODS AND RESULTS: A total of 39 LBBAP patients, 42 RVSP patients, and 93 healthy control participants were retrospectively evaluated. We compared phase analysis- (bandwidth, phase standard deviation [PSD], entropy) and regional wall motion analysis parameters. Wall motion analysis parameters included the time to the end-systolic frame (TES) assessed using single-photon emission computed tomography analysis. The maximum differences between segmental TES (MDTES), the standard deviation of TES (SDTES), and the TES difference between the lateral and septal segments (DTES-LS) were obtained. All phase analysis parameters were significantly smaller in the LBBAP group than in the RVSP group (bandwidth: LBBAP, 74 ± 31° vs. RVSP, 102 ± 59°, p = .009; PSD: LBBAP, 19 ± 6.7° vs. RVSP, 26 ± 15°, p = .007; entropy: LBBAP, 0.57 ± 0.07 vs. RVSP, 0.62 ± 0.11 p = .009). The regional wall motion analysis parameters were also smaller in the LBBAP group than in the RVSP group (MDTES:LBBAP, 17 ± 7.1% vs. RVSP, 25 ± 14%, p = .004; SDTES:LBBAP, 4.5 ± 1.7% vs. RVSP, 6.0 ± 3.5%, p = .015; DTES-LS: LBBAP, 4.1 ± 3.4% vs. RVSP, 7.1 ± 5.4%, p = .004). All phase analysis and wall motion analysis parameters were same in the LBBAP and control groups. CONCLUSION: LBBAP may reduce mechanical dyssynchrony and achieve greater physiological ventricular activation than RVSP.


Assuntos
Fascículo Atrioventricular , Marca-Passo Artificial , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Humanos , Imagem de Perfusão , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
Int Heart J ; 63(3): 623-626, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35569963

RESUMO

Implantation of a cardiac resynchronization therapy (CRT) device is usually scheduled in the compensated phase of heart failure; however, procedural safety may be sometimes disturbed in the decompensated phase. We report a case of a successful semi-urgent implantation of a CRT device temporary assisted with Impella in a patient with the decompensated phase of severe heart failure dependent on inotropic agents and who cannot maintain the supine position. Impella assistance with left ventricular (LV) unloading and maintenance of end-organ perfusion contributed to early recovery from acute heart failure. Furthermore, an acute effect of mechanical resynchronization by biventricular pacing plays an important role in weaning from the mechanical support or inotropic dependence. These mutual effects of mechanical support and CRT might contribute to a decrease in LV end-diastolic pressure and to a remarkable early recovery from a severely decompensated condition.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Resultado do Tratamento
12.
PLoS One ; 17(4): e0266939, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35413085

RESUMO

Pulmonary vein isolation has become a cornerstone treatment for catheter ablation of atrial fibrillation (AF). Recent reports show that additional ablation targeting low-voltage zones reduces AF recurrence. However, the pre-procedural predictors of low-voltage zones remain elusive. We retrospectively enrolled 359 patients (mean age 63.7 ± 10.8 years; 73 females; and 149 had persistent atrial fibrillation) who underwent catheter ablation for AF and left atrial (LA) voltage mapping during sinus rhythm or atrial pacing. Low-voltage zones were defined as area of > 5 cm2 with a bipolar electrogram amplitude of < 0.50 mV. Overall, 51 (14.2%) patients had low-voltage zones. Patients with low-voltage zones were older (67.9 ± 9.9 vs. 63.0 ± 10.8 years; P = 0.003), predominantly female (33.3% vs. 18.2%; P = 0.013), had higher prevalence of dilated cardiomyopathy (DCM) (11.8% vs. 1.6%; P = 0.002) and hypertrophic cardiomyopathy (HCM) (9.8% vs. 2.6%; P = 0.025), and had larger LA volumes (153.6 ± 46.4 vs. 117.7 ± 67.8 mL; P < 0.001) than those without low-voltage zones. Multivariate logistic regression analysis revealed that age (OR 1.060; 95% CI 1.022-1.101, P = 0.002), female sex (OR 2.978; 95% CI 1.340-6.615, P = 0.007), DCM (OR 8.341; 95% CI 1.381-50.372, P = 0.021), HCM (OR 5.044; 95% CI 1.314-19.363, P = 0.018), persistent AF (OR 4.188; 95% CI 1.928-9.100, P < 0.001), and larger LA volume (OR 3.215; 95% CI 1.378-7.502, P = 0.007) were independently associated with the presence of low-voltage zones. Patient age, female sex, DCM, HCM, persistent AF and larger LA volume may predict the presence of low-voltage zones and could be useful in selecting the appropriate ablation strategy for AF.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
13.
Europace ; 24(8): 1284-1290, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34919657

RESUMO

AIMS: This study aimed to investigate the intraventricular blood flow pattern of patients with left bundle branch block (LBBB) using four-dimensional flow magnetic resonance imaging (4D-flow MRI). METHODS AND RESULTS: We performed 4D-flow MRI for 16 LBBB patients (LBBB group) and 16 propensity score-matched patients with a normal QRS duration (non-LBBB group). The energy loss (EL) in the left ventricle was evaluated. In both groups, blood flow from the mitral valve to the apex of the heart and left ventricular (LV) outflow tract during LV diastole were observed. Vortices were also observed in both groups. There were two patterns of vortices: unidirectional clockwise rotation and counterclockwise rotation taking place from the mid-diastole to the systole (reverse pattern). The reverse pattern was observed significantly more frequently in the LBBB group (LBBB 94% vs. non-LBBB 19%, P < 0.001). The interobserver agreement for the streamline analysis was good (kappa = 0.68). The maximum EL was significantly higher in the LBBB group [LBBB 12 (11-15) mW vs. non-LBBB 8.0 (6.2-9.7) mW, P < 0.001]. CONCLUSION: Left bundle branch block patients may suffer from inefficient LV haemodynamics reflected by non-physiological counterclockwise vortices and increased EL. Thus, the shape of the vortices and EL in the left ventricle can serve as markers of LV mechanical dyssynchrony in LBBB patients and could be investigated as predictors of response to cardiac resynchronization therapy.


Assuntos
Terapia de Ressincronização Cardíaca , Disfunção Ventricular Esquerda , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Ventrículos do Coração , Humanos , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda
14.
Circ Arrhythm Electrophysiol ; 15(1): e010516, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34962134

RESUMO

BACKGROUND: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. METHODS: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. RESULTS: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was -49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. CONCLUSIONS: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03645577. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Doença Iatrogênica , Traumatismos dos Nervos Periféricos/epidemiologia , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/diagnóstico , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
J Cardiol Cases ; 23(5): 218-220, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33995700

RESUMO

Both a multicenter cohort and a post-approval registry of the Micra™ transcatheter pacemaker (Medtronic, Minneapolis, MN, USA) reported high successful implantation rates (>99%) with long-term stability of electrical performance and long-term safety. Therefore, there has been little discussion on the causes of cases of failure in terms of anatomical findings. We report a case of failure of implantation of the Micra because of a tortuous inferior vena cava (IVC) secondary to severe scoliosis. A retrospective assessment of 3D reconstructed computed tomography imaging could visualize the configuration of the IVC-right atrium junction. A preprocedural anatomical assessment may help to predict the implantability of the transcatheter leadless pacemaker or to image the manipulation of the delivery catheter. 99%). There has been little discussion on the causes of cases of failure in terms of anatomical findings. We report a case of failure of implantation of the Micra device because of a tortuous inferior vena cava secondary to severe scoliosis. A preprocedural 3D reconstructed computed tomography may help to predict the procedural difficulty of the Micra implantation or to image a manipulation of the delivery catheter.>.

16.
J Arrhythm ; 37(2): 448-449, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33850588

RESUMO

We report a case with a thrombus-like image on pulmonary valve detected by intracardiac echocardiography before transseptal puncture for atrial fibrillation (AF) ablation. The multimodality assessment provided diagnosis of the imaging artifact and exclusion from the harmful mass. This finding could be useful for a safety management of AF ablation and avoidance of an unnecessary interruption of the procedure.

17.
Eur Heart J Case Rep ; 5(2): ytaa570, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33644658

RESUMO

BACKGROUND: Hypertrophic obstructive cardiomyopathy (HOCM) is sometimes concomitant with atrial fibrillation (AF) and exacerbates heart failure symptoms. Although optimal medication for the reduction of left ventricular outflow tract (LVOT) obstruction and the maintenance of sinus rhythm should be considered, it is difficult to control the symptoms permanently. CASE SUMMARY: A 45-year-old man, diagnosed with HOCM, presented with progressive dyspnoea on exertion, which significantly deteriorated during episodes of paroxysmal AF, despite optimal medical therapy. On echocardiography, we found LVOT obstruction with a peak pressure gradient of 98 mmHg, concomitant with redundant mitral valve leaflets, which caused significant systolic anterior motion (SAM). Since he declined open surgery, we selected a combination of catheter interventions, AF ablation, and alcohol septal ablation (ASA). After the AF ablation, the occurrence of AF significantly decreased, and there was no recurrence after the ASA. By 6 months, the plasma N-terminal pro-B-type natriuretic peptide level had decreased from 1022 to 124 pg/mL, the peak pressure gradient of LVOT decreased from 98 to 12 mmHg, and the left atrium volume decreased from 203 to 178.4 mL. The improvement in the SAM was visualized on echocardiography and was haemodynamically corroborated by the four-dimensional (4D)-flow cardiac magnetic resonance (CMR). DISCUSSION: The treatment of drug-refractory HOCM concomitant with paroxysmal AF needs both septal reduction and the maintenance of sinus rhythm, which can be accomplished through transcatheter interventions. Moreover, the detailed intra-ventricular haemodynamic assessment in HOCM patients can be explored using the 4D-flow CMR.

18.
Heart Vessels ; 36(7): 1056-1063, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33507356

RESUMO

Right ventricular (RV) septum is an alternate site for the placement of RV lead tip instead of RV apex. Recent studies have demonstrated that less than half of the RV leads targeted for septal implantation are placed on the RV septum using a conventional stylet system; new guiding catheter systems have become available for RV lead placement. This study aimed to investigate the usefulness of the delivery catheter system in lead placement on the RV septum when compared with the stylet system. We retrospectively evaluated 198 patients who underwent fluoroscopically guided pacemaker implantation with RV leads targeted to be placed in the RV septum and in whom computed tomography was incidentally and subsequently performed. A delivery catheter was used in 16 patients, and a stylet in 182 patients. The primary endpoint of this study was the success rate of RV lead placement on the RV septum. The proportion of RV lead placement on the RV septum was higher in the delivery catheter group than in the stylet group (100% vs. 44%; p < 0.001). In the stylet group, the lead tips were placed at the hinge in 92 cases (51%) and on the free wall in 9 cases (5%). Paced QRS duration was narrower in the delivery catheter group than in the stylet group (128 ± 16 vs. 150 ± 21 ms, p < 0.01). The delivery catheter system designated for pacing leads may aid in selecting RV septal sites and achieve good physiologic ventricular activation.


Assuntos
Arritmias Cardíacas/terapia , Marca-Passo Artificial/estatística & dados numéricos , Função Ventricular Direita/fisiologia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia/métodos , Desenho de Equipamento , Feminino , Fluoroscopia/métodos , Seguimentos , Ventrículos do Coração , Humanos , Masculino , Estudos Retrospectivos , Septo Interventricular
19.
Circ J ; 83(9): 1901-1907, 2019 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-31308318

RESUMO

BACKGROUND: Although previous studies have suggested a certain prevalence of Fabry disease (FD) in left ventricular hypertrophy (LVH) patients, the screening of FD is difficult because of its wide-ranging clinical phenotypes. We aimed to clarify the utility of combined measurement of plasma globotriaosylsphingosine (lyso-Gb3) concentration and α-galactosidase A activity (α-GAL) as a primary screening of FD in unexplained LVH patients.Methods and Results:Between 2014 and 2016, both lyso-Gb3 and α-GAL were measured in 277 consecutive patients (male 215, female 62, age 25-79 years) with left ventricular wall thickness >12 mm on echocardiogram: 5 patients (1.8%) screened positive (2 (0.7%) showed high lyso-Gb3 and 4 (1.4%) had low α-GAL levels). Finally, 2 patients (0.7%) were diagnosed with clinically significant FD. In 1 case, a female heterozygote with normal α-GAL levels had genetic variants of unknown significance and was diagnosed as FD by endomyocardial biopsy. The other case was a male chronic renal failure patient requiring hemodialysis, and he had a p.R112H mutation. In both cases there were high lyso-Gb3 levels. CONCLUSIONS: The serum lyso-Gb3 level can be relevant for clinically significant FD, and combined measurement of lyso-Gb3 and α-GAL can provide better screening of FD in unexplained LVH patients.


Assuntos
Doença de Fabry/sangue , Glicolipídeos/sangue , Hipertrofia Ventricular Esquerda/sangue , Esfingolipídeos/sangue , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Doença de Fabry/diagnóstico por imagem , Doença de Fabry/genética , Doença de Fabry/fisiopatologia , Feminino , Predisposição Genética para Doença , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/genética , Hipertrofia Ventricular Esquerda/fisiopatologia , Japão , Masculino , Pessoa de Meia-Idade , Mutação , Valor Preditivo dos Testes , Estudos Prospectivos , Função Ventricular Esquerda , Remodelação Ventricular , Adulto Jovem , alfa-Galactosidase/sangue , alfa-Galactosidase/genética
20.
J Cardiovasc Electrophysiol ; 30(8): 1200-1206, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31045300

RESUMO

INTRODUCTION: Phrenic nerve (PN) injury is a well-known complication of cryoballoon ablation (CBA) for pulmonary vein (PV) isolation in patients with atrial fibrillation. However, it is still insufficient to practically predict phrenic nerve injury (PNI) before freezing. We hypothesized that phrenic nerve capture (PNC) with phrenic nerve orifice pacing (PVOP) might be a surrogate sign of the close proximity of the PN, and that might predict PNI and changes in the compound motor action potential (CMAP) amplitude. METHODS: Seventy patients (60 ± 12 years, male 80%, paroxysmal 56%) underwent PVOP with a 20-electrode ring catheter before the CBA. The clinical outcome was the occurrence of transient and persistent PNI. In addition, the PV position and pacing threshold during PNC with PVOP, and changes in the CMAP amplitude were recorded. We compared these measurements between patients with and without PNC (PNC/non-PNC group) with PVOP. RESULTS: PNC with PVOP occurred in 39 (56%) patients and was localized only to the right superior PV. Transient PNI occurred in seven (10%) patients and permanent in none. The CMAP amplitude decreased significantly more in the PNC group (PNC 33% vs non-PNC 16%, P = .027). PNC group had a higher risk of the composite outcome of transient PNI or ≥30% decrease in the CMAP amplitude (PNC 54% vs non-PNC 13%; P < .001). CONCLUSIONS: This PVOP technique could be feasible and contribute to predicting transient PNI and CMAP amplitude reductions before cryoapplications. Further studies are necessary to elucidate the additional efficacy of PVOP over CMAP monitoring alone.


Assuntos
Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial , Criocirurgia/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Traumatismos dos Nervos Periféricos/etiologia , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Potencial Evocado Motor , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/diagnóstico , Traumatismos dos Nervos Periféricos/fisiopatologia , Nervo Frênico/fisiopatologia , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Medição de Risco , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA