Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 12(2): 024028, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17477743

RESUMO

A coherent light beam is used to interrogate the focal region within a tissue-mimicking phantom insonified by an ultrasound transducer. The ultrasound-tagged photons exiting from the object carry with them information on local optical path length fluctuations caused by refractive index variations and medium vibration. Through estimation of the force distribution in the focal region of the ultrasound transducer, and solving the forward elastography problem for amplitude of vibration of tissue particles, we observe that the amplitude is directed along the axis of the transducer. It is shown that the focal region interrogated by photons launched along the transducer axis carries phase fluctuations owing to both refractive index variations and particle vibration, whereas the photons launched perpendicular to the transducer axis carry phase fluctuations arising mainly from the refractive index variations, with only smaller contribution from vibration of particles. Monte-Carlo simulations and experiments done on tissue-mimicking phantoms prove that as the storage modulus of the phantom is increased, the detected modulation depth in autocorrelation is reduced, significantly for axial photons and only marginally for the transverse-directed photons. It is observed that the depth of modulation is reduced to a significantly lower and constant value as the storage modulus of the medium is increased. This constant value is found to be the same for both axial and transverse optical interrogation. This proves that the residual modulation depth is owing to refractive index fluctuations alone, which can be subtracted from the overall measured modulation depth, paving the way for a possible quantitative reconstruction of storage modulus. Moreover, since the transverse-directed photons are not significantly affected by storage modulus variations, for a quantitatively accurate read-out of absorption coefficient variation, the interrogating light should be perpendicular to the focusing ultrasound transducer axis.


Assuntos
Biomimética/instrumentação , Tecido Conjuntivo/diagnóstico por imagem , Tecido Conjuntivo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Palpação/métodos , Refratometria/métodos , Ultrassonografia/métodos , Fenômenos Biomecânicos , Simulação por Computador , Modelos Biológicos , Imagens de Fantasmas , Vibração
3.
J Commun Dis ; 31(2): 121-6, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10810600

RESUMO

Freund's complete adjuvant (FCA) treated group of mice when challenged with lethal Plasmodium berghei showed increased survival value; survival period (SP) and median survival day (MSD) compared to their respective control groups. K values were affected and mean parasitaemia during infection period was lower than that of control. In general survival rate after 35 days of infection was 10.5% in FCA recipients. The survival rate in a particular group of animals which received 0.2 ml FCA 3 days before challenge was 22.7%. FCA was found to contribute to increased survival of the host against P. berghei infection. The study indicates that adjuvants, like FCA induce protective immunity and future studies should include non-specific immunization against human malaria.


Assuntos
Adjuvante de Freund , Macrófagos/imunologia , Malária/prevenção & controle , Plasmodium berghei/imunologia , Animais , Humanos , Malária/imunologia , Malária/parasitologia , Masculino , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA