Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Heart Vessels ; 31(9): 1412-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26498755

RESUMO

Anaortic coronary artery bypass proved to prevent early neurologic injury compared to on-pump CABG. The Cardica PAS-Port(®) is a fully automated device that might be able to perform proximal aorto-venous anastomoses without an increased embolic risk. We evaluated early post-operative neurologic outcome in a matched population following clampless OPCAB (CCAB: either "all-arterial" or with automatically anastomosed venous grafts) or on-pump CABG. 366 consecutive patients were submitted to isolated coronary bypass by a single surgeon experienced in both off and on-pump procedures between January 2009 and December 2013. Of these patients, 223 underwent a clampless off-pump revascularization. After propensity score matching, 143 pairs were selected, who received either off-pump or on-pump surgery. In the off-pump group, CCAB was performed with an all-arterial approach (n = 33) or with automated proximal anastomosis of the venous graft(s) by means of the Cardica PAS-Port(®) connector (n = 110). Neurologic injury was defined as non-reversible (NRNI: lethal coma or stroke) or reversible (RNI: TIA or delirium). Operative mortality was 2.4 % (CCAB 1.4 %; CABG 3.5 %; p = 0.14). The global rate of early neurologic injury was 5.6 % (CCAB 2.1 vs. CABG 9.1 %; p = 0.006). Incidence was 1.4 % for NRNI (CCAB 0 vs. CABG 2.8 %; p = 0.04) and 4.2 % for RNI (CCAB 2.1 vs. CABG 6.3 %; p = 0.06). No differences were found among other major perioperative outcomes. CCAB prevents both early post-operative RNI and NRNI. This result can be achieved with a totally anaortic strategy and also with the aid of a fully automated device for proximal aorto-venous anastomoses.


Assuntos
Ponte Cardiopulmonar , Transtornos Cerebrovasculares/prevenção & controle , Ponte de Artéria Coronária sem Circulação Extracorpórea , Ponte de Artéria Coronária/métodos , Idoso , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/mortalidade , Transtornos Cerebrovasculares/diagnóstico , Transtornos Cerebrovasculares/etiologia , Transtornos Cerebrovasculares/mortalidade , Distribuição de Qui-Quadrado , Coma/etiologia , Coma/prevenção & controle , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/instrumentação , Ponte de Artéria Coronária sem Circulação Extracorpórea/mortalidade , Delírio/etiologia , Delírio/prevenção & controle , Desenho de Equipamento , Feminino , Mortalidade Hospitalar , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Pontuação de Propensão , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
2.
J Card Surg ; 29(3): 325-32, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24883445

RESUMO

OBJECTIVE: To evaluate long-term clinical performance and angiographic patency of automated proximal venous anastomoses following clampless coronary artery bypass (C-CAB). METHODS: Observational study in patients submitted for isolated C-CAB and at least one proximal aortosaphenous anastomosis performed with an automated connector (Cardica PAS-Port) including 152 consecutive patients (165 devices and 199 device-dependent distal anastomoses), with LVEF > 30% and saphenous vein diameter of 4-6 mm. Clinical follow-up was 96% complete (4101/4269 pt-months). Graft patency rate was assessed with 64-slice CT-scan or coronary angiography. Freedom from major adverse cardiac and cerebrovascular events (MACCE) was reported as actuarial probability with 95% confidence limits and venous graft patency as actual rate at every year interval. RESULTS: Early operative mortality was 1.9%; incidence of neurologic injury was zero. Freedom from MACCE was 92.7 ± 2.1 at one year and 85.2 ± 4.8 at five years. The actual patency rate of device-dependent venous grafts was 90%, 85%, 84%, 84%, and 93% for one-, two-, three-, four-, and five-year-old grafts, respectively. CONCLUSIONS: The device is a well-performing system for proximal anastomoses. The incidence of neurologic complications seems to be reduced with this clampless approach. The high patency rate is stable over time.


Assuntos
Anastomose Cirúrgica/instrumentação , Ponte de Artéria Coronária/métodos , Pancreatite do Enxerto , Grau de Desobstrução Vascular , Idoso , Aorta/cirurgia , Doenças Cardiovasculares/epidemiologia , Transtornos Cerebrovasculares/epidemiologia , Angiografia Coronária , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatite do Enxerto/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Veia Safena/cirurgia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA