Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Open Heart ; 7(2)2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33132209

RESUMO

OBJECTIVES: The aim of this study was to investigate the impact of acute left ventricular unloading by percutaneous left ventricular assist device on pulmonary congestion and pneumonia in patients with cardiogenic shock (CS). METHODS: In this retrospective study, we analysed patients with CS who received the Impella percutaneous left ventricular assist device (n=50) compared with those who received intra-aortic balloon pump (IABP) support (n=50). Pulmonary congestion was longitudinally assessed while on support by calculating characteristic findings on the chest X-ray using the Halperin score. The rate of pneumonia and early mortality were assessed as a secondary endpoint. RESULTS: The groups (Impella vs IABP) did not differ in terms of age, Sequential Organ Failure Assessment (SOFA) score, Acute Physiology, Chronic Health Evaluation (APACHE) II score or serum lactate levels. Pulmonary congestion decreased in patient treated with Impella at each time point postimplantation. No change in congestion status was observed in patients supported with IABP. Multivariate analysis indicated Impella support as an independent predictor for pulmonary decongestion (OR 4.06, 95% CI 1.15 to 14.35, p=0.030). The rate of early pneumonia was lower in the Impella group compared with the IABP group (54% vs 74%, p=0.037). Failure of pulmonary decongestion during mechanical circulatory support independently predicted early pneumonia (OR 0.28, 95% CI 0.12 to 0.70, p=0.006). CONCLUSION: Pulmonary decongestion may facilitate treatment of pneumonia in patients with CS. Left ventricular unloading by Impella device might support pulmonary decongestion, although a larger prospective trial in this patient population is required.


Assuntos
Coração Auxiliar , Balão Intra-Aórtico , Pneumonia/prevenção & controle , Implantação de Prótese/instrumentação , Edema Pulmonar/prevenção & controle , Choque Cardiogênico/terapia , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/mortalidade , Masculino , Pessoa de Meia-Idade , Pneumonia/diagnóstico , Pneumonia/mortalidade , Pneumonia/fisiopatologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Edema Pulmonar/diagnóstico , Edema Pulmonar/mortalidade , Edema Pulmonar/fisiopatologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA