1.
J Neurosurg ; : 1-8, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701528

RESUMO

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

2.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483647

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/etiologia , Embolização Terapêutica/efeitos adversos , Pontuação de Propensão , Estudos Retrospectivos , Estudos de Coortes , Procedimentos Endovasculares/efeitos adversos
3.
Semin Hear ; 45(1): 123-140, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38370522

RESUMO

Tinnitus acoustic therapy is defined as any use of sound where the intent is to alter the tinnitus perception and/or the reactions to tinnitus in a clinically beneficial way. The parameters of sound that may cause beneficial effects, however, are currently only theorized with limited data supporting their effectiveness. Residual inhibition is the temporary suppression or elimination of tinnitus that is usually observed following appropriate auditory stimulation. Our pilot study investigated the effects of a therapeutic acoustic stimulus that was individually customized to maximize residual inhibition of tinnitus and extend its duration to determine if there could be a sustained suppression of the tinnitus signal (i.e., reduced tinnitus loudness) and a reduction in the psychological and emotional reactions to tinnitus. This pilot study had two objectives: (1) to evaluate the feasibility of residual inhibition technique therapy through daily use of hearing aids and (2) to determine its effects by measuring reactionary changes in tinnitus with the Tinnitus Functional Index (TFI) and perceptual changes in tinnitus loudness. A total of 20 adults (14 males, 6 females; mean age: 58 years, SD = 12.88) with chronic tinnitus were enrolled in a four-visit study that consisted of the following: (1) baseline visit and initiation of the intervention period, (2) a 1-month postintervention visit, (3) 2-month postintervention visit and initiation of a wash-out period, and (4) a 3-month visit to assess the wash-out period and any lasting effects of the intervention. The intervention consisted of fitting bilateral hearing aids and creating an individualized residual inhibition stimulus that was streamed via Bluetooth from a smartphone application to the hearing aids. The participants were instructed to wear the hearing aids and stream the residual inhibition stimulus all waking hours for the 2-month intervention period. During the wash-out period, the participants were instructed to use the hearing aids for amplification, but the residual inhibition stimulus was discontinued. At all visits, the participants completed the TFI, study-specific self-report measures to document perceptions of tinnitus, a psychoacoustic test battery consisting of tinnitus loudness and pitch matching, and a residual inhibition test battery consisting of minimum masking and minimum residual inhibition levels. At the end of the trial, participants were interviewed about the study experience and acceptability of the residual inhibition treatment technique. Repeated measures analyses of variance (ANOVA) were conducted on the two main outcomes (TFI total score and tinnitus loudness) across all four visits. The results showed a significant main effect of visit on the TFI total score ( p < 0.0001). Specifically, the results indicated a significant reduction in TFI total scores from baseline to the 1-month post-intervention period, which remained stable across the 2-month post-intervention period and the wash-out period. The ANOVA results did not show a significant change in tinnitus loudness as a function of visit ( p = 0.480). The majority of the participants reported a positive experience with the study intervention at their exit interview. This pilot study demonstrated that residual inhibition as a sound therapy for tinnitus, specifically through the daily use of hearing aids, was feasible and acceptable to individuals suffering from chronic tinnitus. In addition, participants showed improvement in reactions to tinnitus as demonstrated by sustained reduction in TFI scores on average over the course of the treatment period. Achieving residual inhibition may also provide patients a feeling of control over their tinnitus, and this may have a synergistic effect in reducing the psychological and emotional distress associated with tinnitus. There was no significant reduction in long-term tinnitus loudness resulting from the residual inhibition treatment; however, the current pilot study may not have had sufficient power to detect such a change. The combination of tinnitus suppression and improved psychosocial/emotional reactions to tinnitus may result in a better quality of life in both the short and long term. A larger-scale study is needed to determine the validity of using residual inhibition as a clinical therapy option and to ascertain any effects on both perception and reactions to tinnitus.

4.
J Neurointerv Surg ; 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38238006

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS: This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS: Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS: Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.

5.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862717

RESUMO

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Stents
6.
Am J Audiol ; : 1-9, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38016170

RESUMO

PURPOSE: Persons with cystic fibrosis (PwCF) are at high risk for ototoxicity due to the routine use of intravenous aminoglycoside (IV-AG) antibiotics in respiratory infection management. Additionally, factors that contribute to ototoxicity-related symptom development and severity in PwCF are unknown. Given the increased risk of ototoxicity in people with diabetes, we explored the association between cystic fibrosis-related diabetes (CFRD) and self-reported ototoxicity symptoms (tinnitus and vestibular problems) in PwCF treated with aminoglycosides. METHOD: PwCF (N = 39; 25 females, 14 males; Mage = 30.1 years, SD = 10.3) were recruited from the Cystic Fibrosis Care Center at Oregon Health & Science University. Patients completed the validated questionnaires to ascertain their experiences with ototoxicity-related symptoms of tinnitus and balance function. The diagnosis of CFRD, including oral glucose tolerance testing (OGTT), insulin treatment, hemoglobin A1c, and cumulative IV-AG treatment history, was obtained through a medical chart review. Participants were classified into three groups based on their medical diagnoses via OGTT: normal glucose tolerance (NGT; control; n = 16), abnormal glucose tolerance (AGT; n = 9), and CFRD (n = 14). Participants in each group were further classified based on survey outcomes for ototoxicity-related symptoms. RESULTS: There was a trend toward a higher proportion of patients with CFRD reporting tinnitus compared to the AGT and NGT groups, but did not meet statistical significance (X2 = 2.24, p = .13). Approximately, 43% of patients with CFRD reported experiencing clinically significant tinnitus lasting > 3 min compared to 11% in the AGT group and 13% in the NGT group (X2 = 3.751, p = .05). Cumulative IV-AG exposure tended to be higher in CFRD compared to other groups. High balance function was generally reported in all groups. CONCLUSIONS: Patients with CFRD have greater ototoxicity-related symptoms. Further investigation of the relationship between CF-related comorbidities and the risk of developing ototoxicity-related symptoms is warranted to improve the detection and management of ototoxicity in PwCF.

7.
Transl Stroke Res ; 2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37165289

RESUMO

The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.

8.
Ear Hear ; 44(4): 740-750, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36631948

RESUMO

OBJECTIVES: This study compared the measurement of the acoustic stapedius reflex threshold (ART) obtained using a traditional method with that obtained using an automated adaptive wideband (AAW) method. Participants included three groups of adults with normal hearing (NH), mild sensorineural hearing loss (SNHL), or moderate SNHL. The purpose of the study was to compare ARTs for the three groups and to determine which method had the best performance in detecting SNHL. DESIGN: Ipsilateral and contralateral ARTs were obtained using 0.5, 1, and 2 kHz tonal activators, and broadband noise (BBN) activators on a traditional admittance system (Clinical) at tympanometric peak pressures (TPP) and on an experimental wideband system using an AAW method at both ambient pressure and TPP. ART data previously reported for 39 NH adults with a mean age of 47.7 years were compared with data for 25 participants with mild SNHL with a mean age of 63.8 years, and 20 participants with moderate SNHL with a mean age of 65.7 years. Differences in ARTs between the normal-hearing and SNHL groups for the three methods were examined using a General Linear Model Repeated-Measures test. A receiver operating characteristic curve (ROC) analysis was also used to determine the ability of an ART test to detect SNHL. RESULTS: For the 0.5 kHz activator condition, there were no significant group mean differences in ART between NH and SNHL groups for either ipsilateral or contralateral activator presentation modes for the Clinical or AAW methods. There were significant group mean differences for the 1 and 2 kHz tonal activators and BBN activator for both ipsilateral and contralateral modes with greater differences in ART between groups for the AAW method than the Clinical method. In these conditions, the mean ART was lower for the AAW tests relative to the Clinical test. The greatest difference between groups was for the ipsilateral AAW tests for the comparison of NH with moderate SNHL for the BBN activator. This difference was approximately 20 dB for the AAW tests and 8 dB for the Clinical test. The ROC analysis showed that the area under the ROC curve (AUC) increased with the frequency of the activator stimulus and with the degree of hearing loss and was maximal for the BBN activator for both the AAW and Clinical methods for both ipsilateral and contralateral presentations. CONCLUSIONS: For ipsilateral and contralateral ART tests for activator frequencies above 0.5 kHz and BBN, listeners with SNHL generally had elevated ARTs compared with those with NH. The AAW method resulted in greater differences between SNHL groups and NH than the Clinical method. The AUC for detecting SNHL also increased with activator frequency and degree of hearing loss and was greatest for the BBN activator for the AAW method in both the ambient and TPP conditions. The results are encouraging for the use of an AAW ART method for the assessment of individuals with SNHL.


Assuntos
Surdez , Perda Auditiva Neurossensorial , Perda Auditiva , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estapédio , Limiar Auditivo , Perda Auditiva Neurossensorial/diagnóstico , Testes de Impedância Acústica , Acústica , Audição , Reflexo , Reflexo Acústico
9.
J Neurointerv Surg ; 15(9): 844-850, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35868856

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. METHODS: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. RESULTS: The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. CONCLUSION: There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Embolização Terapêutica/métodos
10.
J Neurointerv Surg ; 15(6): 558-565, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35483912

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device has Food and Drug Administration approval for treatment of wide-necked intracranial bifurcation aneurysms. The WEB device has been shown to result in adequate occlusion in bifurcation aneurysms overall, but its usefulness in the individual bifurcation locations has been evaluated separately only in few case series, which were limited by small sample sizes. OBJECTIVE: To compare angiographic and clinical outcomes after treatment of bifurcation aneurysms at various locations, including anterior communicating artery (AComA), anterior cerebral artery (ACA) bifurcation distal to AComA, basilar tip, internal carotid artery (ICA) bifurcation, and middle cerebral artery (MCA) bifurcation aneurysms using the WEB device. METHODS: A retrospective cohort analysis was conducted at 22 academic institutions worldwide to compare treatment outcomes of patients with intracranial bifurcation aneurysms using the WEB device. Data include patient and aneurysm characteristics, procedural details, angiographic and functional outcomes, and complications. RESULTS: A total of 572 aneurysms were included. MCA (36%), AComA (35.7%), and basilar tip (18.9%) aneurysms were most common. The rate of adequate aneurysm occlusion was significantly higher for basilar tip (91.6%) and ICA bifurcation (96.7%) aneurysms and lower for ACA bifurcation (71.4%) and AComA (80.6%) aneurysms (p=0.04). CONCLUSION: To our knowledge, this is the most extensive study to date that compares the treatment of different intracranial bifurcation aneurysms using the WEB device. Basilar tip and ICA bifurcation aneurysms showed significantly higher rates of aneurysm occlusion than other locations.


Assuntos
Doenças das Artérias Carótidas , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Doenças das Artérias Carótidas/terapia
11.
Transl Stroke Res ; 14(4): 455-464, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36066701

RESUMO

Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011-2015 (N = 66), 2016-2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020-2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
13.
Radiology ; 304(2): 372-382, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35438564

RESUMO

Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the treatment of sidewall aneurysms, with promising outcomes. Purpose To compare the angiographic and clinical outcomes of the WEB device for the treatment of sidewall aneurysms compared with the treatment of bifurcation aneurysms. Materials and Methods A retrospective review of the WorldWideWEB Consortium, a synthesis of retrospective databases spanning from January 2011 to June 2021 at 22 academic institutions in North America, South America, and Europe, was performed to identify patients with intracranial aneurysms treated with the WEB device. Characteristics and outcomes were compared between bifurcation and sidewall aneurysms. Propensity score matching (PSM) was used to match by age, pretreatment ordinal modified Rankin Scale score, ruptured aneurysms, location of aneurysm, multiple aneurysms, prior treatment, neck, height, dome width, daughter sac, and incorporated branch. Results A total of 683 intracranial aneurysms were treated using the WEB device in 671 patients (median age, 61 years [IQR, 53-68 years]; male-to-female ratio, 1:2.5). Of those, 572 were bifurcation aneurysms and 111 were sidewall aneurysms. PSM was performed, resulting in 91 bifurcation and sidewall aneurysms pairs. No significant difference was observed in occlusion status at last follow-up, deployment success, or complication rates between the two groups. Conclusion No significantly different outcomes were observed following the off-label use of the Woven EndoBridge, or WEB, device for treatment of sidewall aneurysms compared with bifurcation aneurysms. The correct characterization of the sidewall aneurysm location, neck angle, and size is crucial for successful treatment and lower retreatment rate. © RSNA, 2022 See also the editorial by Hetts in this issue.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Aneurisma Roto/terapia , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
14.
J Neurosurg ; : 1-8, 2022 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-35120326

RESUMO

OBJECTIVE: Transradial access (TRA) is commonly utilized in neurointerventional procedures. This study compared the technical and clinical outcomes of the use of TRA versus those of transfemoral access (TFA) for intracranial aneurysm embolization with the Woven EndoBridge (WEB) device. METHODS: This is a secondary analysis of the Worldwide WEB Consortium, which comprises multicenter data related to adult patients with intracranial aneurysms who were managed with the WEB device. These aneurysms were categorized into two groups: those who were treated with TRA or TFA. Patient and aneurysm characteristics and technical and clinical outcomes were compared between groups. Propensity score matching (PSM) was used to match groups according to the following baseline characteristics: age, sex, subarachnoid hemorrhage, aneurysm location, bifurcation aneurysm, aneurysm with incorporated branch, neck width, aspect ratio, dome width, and elapsed time since the last follow-up imaging evaluation. RESULTS: This study included 682 intracranial aneurysms (median [interquartile range] age 61.3 [53.0-68.0] years), of which 561 were treated with TFA and 121 with TRA. PSM resulted in 65 matched pairs. After PSM, both groups had similar characteristics, angiographic and functional outcomes, and rates of retreatment, thromboembolic and hemorrhagic complications, and death. TFA was associated with longer procedure length (median 96.5 minutes vs 72.0 minutes, p = 0.006) and fluoroscopy time (28.2 minutes vs 24.8 minutes, p = 0.037) as compared with TRA. On the other hand, deployment issues were more common in those treated with TRA, but none resulted in permanent complications. CONCLUSIONS: TRA has comparable outcomes, with shorter procedure and fluoroscopy time, to TFA for aneurysm embolization with the WEB device.

15.
Stroke ; 53(2): e47-e49, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34915737
16.
Am J Audiol ; 30(3S): 800-809, 2021 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-34549989

RESUMO

Purpose Specific classes of antibiotics, such as aminoglycosides, have well-established adverse events producing permanent hearing loss, tinnitus, and balance and/or vestibular problems (i.e., ototoxicity). Although these antibiotics are frequently used to treat pseudomonas and other bacterial infections in patients with cystic fibrosis (CF), there are no formalized recommendations describing approaches to implementation of guideline adherent ototoxicity monitoring as part of CF clinical care. Method This consensus statement was developed by the International Ototoxicity Management Working Group (IOMG) Ad Hoc Committee on Aminoglycoside Antibiotics to address the clinical need for ototoxicity management in CF patients treated with known ototoxic medications. These clinical protocol considerations were created using consensus opinion from a community of international experts and available evidence specific to patients with CF, as well as published national and international guidelines on ototoxicity monitoring. Results The IOMG advocates four clinical recommendations for implementing routine and guideline adherent ototoxicity management in patients with CF. These are (a) including questions about hearing, tinnitus, and balance/vestibular problems as part of the routine CF case history for all patients; (b) utilizing timely point-of-care measures; (c) establishing a baseline and conducting posttreatment evaluations for each course of intravenous ototoxic drug treatment; and (d) repeating annual hearing and vestibular evaluations for all patients with a history of ototoxic antibiotic exposure. Conclusion Increased efforts for implementation of an ototoxicity management program in the CF care team model will improve identification of ototoxicity signs and symptoms, allow for timely therapeutic follow-up, and provide the clinician and patient an opportunity to make an informed decision about potential treatment modifications to minimize adverse events. Supplemental Material https://doi.org/10.23641/asha.16624366.


Assuntos
Fibrose Cística , Aminoglicosídeos/efeitos adversos , Antibacterianos/efeitos adversos , Fibrose Cística/complicações , Fibrose Cística/diagnóstico , Fibrose Cística/tratamento farmacológico , Audição , Testes Auditivos , Humanos
17.
Biomed Res Int ; 2021: 6610908, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34239927

RESUMO

BACKGROUND: Parkinson's disease (PD) patients are at increased risk for central auditory processing (CAP) deficits and cognitive dysfunction. However, behavioral assessments of CAP and cognitive processing used in a previous study by our research team found few significant differences in performance between early-stage PD patients and age-matched control subjects. The objective of this study is to use auditory event-related potentials (AERPs) to compare CAP and cognitive functions in a population of PD patients with a group of age-matched control subjects. METHODS: AERPs in response to tonal and speech stimuli were recorded from 35 adults who had a medical diagnosis of PD (23 males and 12 females; mean age = 66.9 ± s.d.11.2 years), and 35 age-matched control subjects who did not have PD or any other neurological disorders (31 males and 4 females; mean age = 65.4 ± s.d.12.3 years). Auditory stimuli included pure tones (500 and 1000 Hz) to elicit the P300 response and a dichotic digits paradigm to elicit the N200 processing negativity. RESULTS: Compared to control subjects, PD patients exhibited significantly longer latencies of P300 and N200 components and smaller amplitude N200 components. Latency and amplitude of the N200 component were significantly correlated with participants' age. N200 amplitude was correlated with results from the Rey Auditory Verbal Learning Test (RAVLT) of cognitive ability. Latency of the P300 and amplitude of the N200 components were significantly correlated with results from the Spatial Release From Masking (SRM) behavioral CAP assessment. CONCLUSIONS: AERP assessments used in this study appear to be sensitive indicators of CAP and cognitive deficits exhibited by early-stage PD patients. While few significant differences in performance on behavioral CAP and cognitive tests were previously observed between this population of PD patients and age-matched control subjects, N200 and P300 components recorded in the present study revealed impaired neural processing by the PD group.


Assuntos
Transtornos da Percepção Auditiva/complicações , Transtornos Cognitivos/complicações , Eletrofisiologia/métodos , Doença de Parkinson/complicações , Idoso , Audiometria , Audiometria de Tons Puros , Transtornos da Percepção Auditiva/fisiopatologia , Comportamento , Encéfalo/fisiopatologia , Estudos de Casos e Controles , Transtornos Cognitivos/fisiopatologia , Disfunção Cognitiva/fisiopatologia , Potenciais Evocados P300/fisiologia , Potenciais Evocados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Doença de Parkinson/fisiopatologia
18.
J Am Acad Audiol ; 32(4): 235-245, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-34062603

RESUMO

BACKGROUND: The study examined follow-up rates for pursuing hearing health care (HHC) 6 to 8 months after participants self-administered one of three hearing screening methods: an automated method for testing of auditory sensitivity (AMTAS), a four-frequency pure-tone screener (FFS), or a digits-in-noise test (DIN), with and without the presentation of a 2-minute educational video about hearing. PURPOSE: The study aims to determine if the type of self-administered hearing screening method (with or without an educational video) affects HHC follow-up rates. RESEARCH DESIGN: The study is a randomized controlled trial of three automated hearing screening methods, plus control group, with and without an educational video. The control group completed questionnaires and provided follow-up data but did not undergo a hearing screening test. STUDY SAMPLE: The study sample includes 1,665 participants (mean age 50.8 years; 935 males) at two VA Medical Centers and at university and community centers in Portland, OR; Bay Pines, FL; Minneapolis, MN; Mauston, WI; and Columbus, OH. DATA COLLECTION AND ANALYSIS: HHC follow-up data at 6 to 8 months were obtained by contacting participants by phone or mail. Screening methods and participant characteristics were compared in relation to the probability of participants pursuing HHC during the follow-up period. RESULTS: The 2-minute educational video did not have a significant effect on HHC follow-up rates. When all participants who provided follow-up data are considered (n = 1012), the FFS was the only test that resulted in a significantly greater percentage of HHC follow-up (24.6%) compared with the control group (16.8%); p = 0.03. However, for participants who failed a hearing screening (n = 467), follow-up results for all screening methods were significantly greater than for controls. The FFS resulted in a greater probability for HHC follow-up overall than the other two screening methods. Moreover, veterans had higher follow-up rates for all screening methods than non-veterans. CONCLUSION: The FFS resulted in a greater HHC follow-up rate compared with the other screening methods. This self-administered test may be more motivational for HHC follow-up because participants who fail the screening are aware of sounds they could not hear which does not occur with adaptive assessments like AMTAS or the DIN test. It is likely that access to and reduced personal cost of audiological services for veterans contributed to higher HHC follow-up rates in this group compared with non-veteran participants.


Assuntos
Testes Auditivos , Audição , Audiometria , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde
19.
J Am Acad Audiol ; 32(6): 355-365, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34062607

RESUMO

BACKGROUND: Age-related changes (both normal and pathological), and health literacy are relevant to audiological practice. Changes associated with the musculoskeletal, vascular, and nervous systems drive manual, visual, and cognitive function. These in turn affect the capabilities required for effective hearing aid (HA) skill acquisition, use, and management. Meanwhile, health literacy influences the ability to gain access to, understand, and use information, which is important for promoting and maintaining HA use and management. Understanding the interindividual variability of these variables can help audiologists characterize those individuals who might have suboptimal HA outcomes. This knowledge can then inform better clinical practices and guide implementation of processes to improve care quality and outcomes. PURPOSE: The aim of the study is to assess the variation in manual, visual, and cognitive function, and health literacy, among community-dwelling older individuals, and to determine whether and which of these variables are associated with reported HA outcome and/or the knowledge and skill to manage HAs. RESEARCH DESIGN: Data presented here were collected as part of an efficacy trial of four variants of HA orientation. The data were collected at baseline (prior to HA fitting) and after 4 to 8 weeks of HA use. STUDY SAMPLE: The study sample consists of 265 U.S. Veterans aged 51 to 87 years with no previous HA experience who were scheduled to receive their first pair of HAs from the Veterans Administration. DATA COLLECTION AND ANALYSIS: We assessed baseline measures of hand function, vision, cognition, and health literacy just prior to participants receiving their first pair of HAs. HA management skills and knowledge, and HA outcome were measured after 4 to 8 weeks of HA use using the Hearing Aid Skills and Knowledge (HASK) and International Outcomes Inventory for Hearing Aids (IOI-HA), respectively. Data collected here was compared with published norms to assess variation in baseline measures. Associations between baseline performance and outcomes data were examined using t-tests comparing participants who performed at or above age-based norms with those who performed below age-based norms. RESULTS: Participants' performance on the baseline measures was highly variable, with the proportions of individuals performing below norms varying by test measure. When combining data across the nine baseline measures, approximately 10% of participants performed below published norms on five or more measures, and 85% performed below norms on at least one measure. Poor manual dexterity, ability to learn a new task, and ability to draw inferences from spoken information negatively impacted HA management and outcome. CONCLUSION: There was a considerable heterogeneity among a community-dwelling sample of first time HA users in terms of sensory, cognitive, and motor function. Clinicians should consider modifying their clinical practice to account for such heterogeneity and best support their patients in adapting to new HAs.


Assuntos
Letramento em Saúde , Auxiliares de Audição , Veteranos , Cognição , Testes Auditivos , Humanos
20.
J Neurointerv Surg ; 13(11): 1012-1016, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33483455

RESUMO

BACKGROUND: The Woven EndoBridge (WEB) device is approved in the USA for treatment of unruptured wide-neck bifurcation aneurysms. However, the safety and effectiveness of the WEB device in the treatment of ruptured intracranial aneurysms is not clear. We aim to evaluate the perioperative safety and effectiveness of the WEB device in patients with ruptured intracranial aneurysms. METHODS: This retrospective study, conducted at eight centers in the USA, included patients with ruptured intracranial aneurysms treated with the WEB device in the setting of subarachnoid hemorrhage (SAH). Safety outcomes included intraoperative complications such as vessel perforation, thromboembolic events, and postoperative hemorrhagic or thromboembolic complications based on radiologic imaging. The primary effectiveness outcome was adequate (complete and neck remnant) aneurysm occlusion, according to the Raymond-Roy classification. RESULTS: A total of 91 patients with 94 ruptured intracranial aneurysms were included (mean age 57.7±15.2 years; 68.1% women; 82.9% wide-necked). Aneurysms were located in the anterior communicating artery (42/94, 44.6%), middle cerebral artery (16/94, 17%), and basilar artery (15/94, 16%). Adequate occlusion was achieved in 48.8% (41/84) and 80.0% (40/50) at discharge and last follow-up (mean of 3.4 months), respectively. At discharge, procedural-related morbidity was 3.3% (3/91) and there was no procedure-related mortality. No re-rupture or delayed aneurysm rupture was observed. CONCLUSIONS: This study demonstrates the perioperative safety and effectiveness of the WEB device for the treatment of patients with ruptured intracranial aneurysms in the setting of SAH, with low periprocedural morbidity and mortality. Long-term follow-up is warranted.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS