1.
Appl Radiat Isot ; 197: 110827, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37086713

RESUMO

An essential issue is an accurate evaluation of surface dose distribution for such sensitive treatments. This work aimed to feasibility of the dual application of the Ferrous Polyvinyl Alcohol Glutaraldehyde Methylthymol Blue (PVA-GTA-MTB) gel as a bolus compensator and surface dosimeter in breast radiotherapy. The differences between the surface dose measured using PVA-GTA-MTB gel and film dosimetry in the medial and lateral parts of the breast were 3.74% and 4.18%, respectively. A qualitative comparison of the isodose curves showed that the PVA-GTA-MTB bolus creates a uniform dose distribution similar to the superflab bolus in the target volume.


Assuntos
Álcool de Polivinil , Radiometria , Radiometria/métodos , Glutaral , Dosímetros de Radiação , Hidrogéis , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Imagens de Fantasmas
2.
J Cancer Res Ther ; 15(3): 498-503, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31169210

RESUMO

PURPOSE: In low-density (LD) gel dosimeter, diffusive spin-spin relaxation rate (R2)-dispersion caused by susceptibility-induced internal gradient leads to a significant deviation in the measured R2 from the real value. In this study, the effect of induced internal gradient on R2 was visualized and quantified algebraically as an important cause of inaccuracy in LD gel dosimeters. MATERIALS AND METHODS: In this method, two sets of LD and unit-density (UD) gel dosimeters were prepared. The LD gel was made by mixing the UD gel with expanded polystyrene spheres. The R2 was used to determine the spatially resolved decay rates due to diffusion in internal magnetic field. The internal gradient was calculated for a multiple spin-echo sequence. RESULTS: It is shown that in a LD gel, the internal gradient leads to overestimation of mean R2 value (R2mean). Pixel-by-pixel R2 measurements inside a LD gel showed significant deviation from R2 mapping in UD gel. CONCLUSION: It appears that significant differences between R2mean in a selected region of interest and pixel-by-pixel R2 values are the main source of inaccuracy in dose mapping of a LD gel.


Assuntos
Géis/química , Géis/efeitos da radiação , Modelos Teóricos , Doses de Radiação , Dosímetros de Radiação , Radioterapia Conformacional , Algoritmos , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Radioterapia Conformacional/efeitos adversos
3.
J Cancer Res Ther ; 14(2): 292-299, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29516909

RESUMO

AIM: Low signal-to-noise ratio (SNR) images of lung-like (low-density [LD]) gel dosimeters, compared to unit-density (UD) gels, necessitate the use of different quantification methods. SETTING AND DESIGN: In this study, a new method is introduced based on noise correction and exponential (NCEXP) fitting. The feasibility of NCEXP method for quantifying dose absorption in LD gels is evaluated. MATERIALS AND METHODS: Sensitivity, dose resolution, detectable dynamic range, and correlation of the calibration curve for both UD and LD gel dosimeters are the parameters, which we analyze to investigate the consequences of new method. Results of NCEXP method are compared to maximum likelihood estimation of rician distribution (MLE-R) and variable echo number (VAREC) quantification methods. RESULTS: Dose response of LD gel dosimeter shows wider detectable dynamic range as compared to UD gel. Using NCEXP method for both LD and UD dosimeter gels, a more sensitive calibration curve with a superior dose resolution is obtained. The advantage of new quantification method is more significant for LD dosimeter gel analysis, where SNR decreases as a result of higher absorbed doses (≥10 Gy). Despite the inverse effect of the VAREC method on detectable dose range of UD gel, no specific changes are observed in dynamic dose range of LD gel dosimeter with different quantification methods. The correlations obtained with different methods were approximately of the same order for UD and LD gels. CONCLUSION: NCEXP method seems to be more effective than the MLE-R and VAREC methods for quantification of LD dosimeter gel, especially where high-dose absorption and steep-dose gradients exist such as those in intensity-modulated radiation therapy and stereotactic radiosurgery.


Assuntos
Géis , Dosímetros de Radiação , Radiometria/métodos , Algoritmos , Relação Dose-Resposta à Radiação , Humanos , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Imageamento por Ressonância Magnética , Aceleradores de Partículas , Doses de Radiação