Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
JACC Case Rep ; 23: 102005, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37954948

RESUMO

Systolic anterior motion of a mitral leaflet can occur by various mechanisms and it is one of the causes of left ventricular outflow tract obstruction after transcatheter mitral valve replacement. We present a case of systolic anterior motion that resolved spontaneously as the anterior mitral leaflet adhered to the prosthesis. (Level of Difficulty: Intermediate.).

2.
Eur J Cardiothorac Surg ; 60(2): 263-273, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-33783480

RESUMO

OBJECTIVES: Although in both the US and European guidelines the 'heart team approach' is a class I recommendation, supporting evidence is still lacking. Therefore, we sought to provide comparative survival data of patients with mitral valve disease referred to the general and the dedicated heart team. METHODS: In this retrospective cohort, patients evaluated for mitral valve disease by a general heart team (2009-2014) and a dedicated mitral valve heart team (2014-2018) were included. Decision-making was recorded prospectively in heart team electronic forms. The end point was overall survival from decision of the heart team. RESULTS: In total, 1145 patients were included of whom 641 (56%) were discussed by dedicated heart team and 504 (44%) by general heart team. At 5 years, survival probability was 0.74 [95% confidence interval (CI) 0.68-0.79] for the dedicated heart team group compared to 0.70 (95% CI 0.66-0.74, P = 0.040) for the general heart team. Relative risk of mortality adjusted for EuroSCORE II, treatment groups (surgical, transcatheter and non-intervention), mitral valve pathology (degenerative, functional, rheumatic and others) and 13 other baseline characteristics for patients in the dedicated heart team was 29% lower [hazard ratio (HR) 0.71, 95% CI 0.54-0.95; P = 0.019] than for the general heart team. The adjusted relative risk of mortality was 61% lower for patients following the advice of the heart team (HR 0.39, 95% CI 0.25-0.62; P < 0.001) and 43% lower for patients following the advice of the general heart team (HR 0.57, 95% CI 0.37-0.87; P = 0.010) compared to those who did not follow the advice of the heart team. CONCLUSIONS: In this retrospective cohort, patients treated for mitral valve disease based on a dedicated heart team decision have significantly higher survival independent of the allocated treatment, mitral valve pathology and baseline characteristics.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Estudos de Coortes , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 97(2): 247-256, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31999077

RESUMO

OBJECTIVES: The aim was to assess long-term outcome after deferring intervention of coronary lesions with a fractional flow reserve (FFR) value of >0.80 in a real-world patient population and then to identify factors associated with deferred target lesion failure (DTLF). BACKGROUND: Deferring coronary interventions of intermediate lesions based on FFR measurement is safe, irrespective of the extent of coronary artery disease. However, FFR values near the cut-off of >0.80 may have less favorable outcome. METHODS: A retrospective analysis was performed in patients with deferred coronary intervention based on FFR value >0.80. The primary endpoint was DTLF, a composite of acute coronary syndrome (ACS) and any coronary revascularization, related to the initially deferred stenosis. RESULTS: A total of 600 patients, mean age of 66 ± 10 years, and 751 coronary lesions with negative FFR values (mean 0.88 ± 0.04) were included. The mean follow-up was 27 ± 15 months. DTLF occurred in 44 patients (7.3%), revascularization in 42 (7%), and ACS without revascularization in 2 patients (0.3%). Patients with DTLF more often had diabetes mellitus, previous coronary artery bypass grafting, multivessel disease (MVD), and lower FFR at inclusion. Multivariable regression analysis showed that lower deferred FFR values [FFR 0.81-0.85: hazard ratio (HR) 2.79 (95% CI [confidence interval]; 1.46-5.32), p .002], MVD [HR 1.98 (95% CI; 1.05-3.75), p .036], distal lesions [HR 2.43 (95% CI; 1.29-4.57), p .006], and lesions located in a saphenous vein graft (SVG) [HR 6.35 (95% CI; 1.81-22.28), p .004] were independent predictors for DTLF. CONCLUSIONS: The long-term rate of DTLF of initially deferred coronary lesions was 7.3%. Independent predictors for DTLF are lower deferred FFR value, the presence of MVD, distal lesions, and lesions in SVG.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Revascularização Miocárdica , Estudos Retrospectivos , Resultado do Tratamento
4.
Ann Thorac Surg ; 110(2): e119-e121, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32032571

RESUMO

To close the left atrial appendage during thoracoscopic ablation of atrial fibrillation, the use of a clipping device has proven to be an elegant and efficacious technique. Although very rare, adequate ostial appendage clipping can provoke coronary artery kinking and thus lead to cardiac ischemia. We describe a minimally invasive surgical technique to deal with this potentially serious complication.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Vasos Coronários , Complicações Intraoperatórias/cirurgia , Toracoscopia , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Vasos Coronários/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Toracoscopia/instrumentação
5.
Innovations (Phila) ; 13(3): 200-206, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29912141

RESUMO

OBJECTIVE: Transapical off-pump minimally invasive mitral valve repair (TOP-MINI) is a new technique for the surgical repair of degenerative mitral regurgitation based on mitral valve prolapse. The aim of this study is to demonstrate the preoperative planning tools available for starting this new procedure in a safe manner. METHODS: The first patients undergoing TOP-MINI by a single surgeon in 2016 were prospectively included. All patients underwent identical clinical pathways and underwent extensive preoperative planning for a safe start of the program. Patients were discussed in our dedicated mitral valve heart-team consisting of diagnostic and interventional mitral valve specialists. All patients underwent computed tomography, transthoracic and transesophageal echocardiography, and mitral valve replication using rapid prototyping. All procedures were performed by the same surgical team. RESULTS: Thirty-six patients were discussed for isolated mitral valve repair in our dedicated mitral valve heart team of which seven patients were deemed eligible for this novel approach. Three-dimensional (3D) reconstructions of computed tomography images allowed the surgical team to determine skin incision level and ideal level of device insertion near the apex of the heart. Echocardiography and rapid prototyping allowed us to assess surgical success probability by determining the amount of tissue overlap and was used intraoperatively for guidance. All patients were operated on successfully, without any major adverse events. CONCLUSIONS: We demonstrate a method to safely start the TOP-MINI program with precise patient selection and preoperative planning, allowing us to determine procedural strategy and assessment of surgical success probability.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/cirurgia , Cuidados Pré-Operatórios , Estudos Prospectivos , Resultado do Tratamento
6.
Int J Cardiovasc Imaging ; 34(11): 1819-1829, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29909590

RESUMO

Incorrect prosthesis size has direct impact on patient outcome after transcatheter aortic valve implantation (TAVI) procedure. Currently, annular diameter, area or perimeter may be used for prosthesis size selection. The aim was to evaluate whether the use different annular dimensions would result in the selection of different prosthesis sizes, when assessed in the same TAVI-candidate during the same phase of a cardiac cycle. Fifty consecutive TAVI-candidates underwent retrospectively ECG-gated computed tomography angiography (CTA). Aortic root dimensions were assessed in the 20% phase of the R-R interval. Annular short diameter, perimeter and area were used to select the prosthesis size, based on the industry recommendations for a self-expandable (Medtronic CoreValve; MCV) and balloon-expandable (Edwards Sapien XT Valve; ESV) valve. Complete agreement on selected prosthesis size amongst all three annular dimensions was observed in 62% (31/50; ESV) and 30% (15/50; MCV). Short aortic annulus measurement resulted in a smaller prosthesis size in 20% (10/50; ESV) and in 60% of cases (30/50; MCV) compared to the size suggested by both annular perimeter and area. In 18% (9/50; ESV) and 10% of cases (5/50; MCV) a larger prosthesis would have been selected based on annular perimeter compared to annular diameter and area. Prosthesis size derived from area was always in agreement with at least one other parameter in all cases. Aortic annulus area appears to be the most robust parameter for TAVI-prosthesis size selection, regardless of the specific prosthesis size. Short aortic annulus diameter may underestimate the prosthesis size, while use of annular perimeter may lead to size overestimation in some cases.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
7.
Interact Cardiovasc Thorac Surg ; 24(2): 163-168, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-27677879

RESUMO

Objectives: Mitral valve repair performed by an experienced surgeon is superior to mitral valve replacement for degenerative mitral valve disease; however, many surgeons are still deterred from adapting this procedure because of a steep learning curve. Simulation-based training and planning could improve the surgical performance and reduce the learning curve. The aim of this study was to develop a patient-specific simulation for mitral valve repair and provide a proof of concept of personalized medicine in a patient prospectively planned for mitral valve surgery. Methods: A 65-year old male with severe symptomatic mitral valve regurgitation was referred to our mitral valve heart team. On the basis of three-dimensional (3D) transoesophageal echocardiography and computed tomography, 3D reconstructions of the patient's anatomy were constructed. By navigating through these reconstructions, the repair options and surgical access were chosen (minimally invasive repair). Using rapid prototyping and negative mould fabrication, we developed a process to cast a patient-specific mitral valve silicone replica for preoperative repair in a high-fidelity simulator. Results: Mitral valve and negative mould were printed in systole to capture the pathology when the valve closes. A patient-specific mitral valve silicone replica was casted and mounted in the simulator. All repair techniques could be performed in the simulator to choose the best repair strategy. As the valve was printed in systole, no special testing other than adjusting the coaptation area was required. Subsequently, the patient was operated, mitral valve pathology was validated and repair was successfully done as in the simulation. Conclusions: The patient-specific simulation and planning could be applied for surgical training, starting the (minimally invasive) mitral valve repair programme, planning of complex cases and the evaluation of new interventional techniques. The personalized medicine could be a possible pathway towards enhancing reproducibility, patient's safety and effectiveness of a complex surgical procedure.


Assuntos
Endoscopia , Insuficiência da Valva Mitral/cirurgia , Modelagem Computacional Específica para o Paciente , Medicina de Precisão , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Transesofagiana , Humanos , Curva de Aprendizado , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA