Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
EuroIntervention ; 19(5): e423-e431, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37171514

RESUMO

BACKGROUND: In patients with complex coronary bifurcation lesions undergoing percutaneous coronary intervention (PCI), various 2-stent techniques might be utilised. The Visible Heart Laboratories (VHL) offer an experimental environment where PCI results can be assessed by multimodality imaging. AIMS: We aimed to assess the post-PCI stent configuration achieved by 2-stent techniques in the VHL and to evaluate the procedural factors associated with suboptimal results. METHODS: Bifurcation PCI with 2-stent techniques, performed by expert operators in the VHL on explanted beating swine hearts, was studied. The adopted bifurcation PCI strategy and the specific procedural steps applied in each procedure were classified according to Main, Across, Distal, Side (MADS)-2 and to their adherence to the European Bifurcation Club (EBC) recommendations. Microcomputed tomography (micro-CT) was used to assess the post-PCI stent configuration. The primary endpoint was "suboptimal stent implantation", defined as a composite of stent underexpansion (<90%), side branch ostial area stenosis >50% and the gap between stents. RESULTS: A total of 82 PCI with bifurcation stenting were assessed, comprised of 29 crush, 25 culotte, 28 T/T and small protrusion (TAP) techniques. Suboptimal stent implantation was observed in as many as 53.7% of the cases, regardless of baseline anatomy or the stenting strategy. However, less frequent use of the proximal optimisation technique (POT; p=0.015) and kissing balloon inflations (KBI; p=0.027) and no adherence to EBC recommendations (p=0.004, p multivariate=0.006) were significantly associated with the primary endpoint. CONCLUSIONS: Commonly practised bifurcation 2-stent techniques may result in imperfect stent configurations. More frequent use of POT/KBI and adherence to expert recommendations might reduce the occurrence of post-PCI suboptimal stent configurations.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Animais , Suínos , Intervenção Coronária Percutânea/métodos , Microtomografia por Raio-X , Resultado do Tratamento , Stents , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia
2.
Physiol Rep ; 11(5): e15630, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36878878

RESUMO

Preclinical research remains the essential platform in the development and optimization of medical therapies and advancements in translational medicines. However, specifically to animal research, federal laws, and institutional policies require investigators to apply the principles of the 3R's (replacement, reduction, and refinement). The concept of benchtop models utilizing isolated organs, in which multiple variables can be controlled to recreate human function, has been innovative advancements in preclinical research models that adhere to these principles. More specifically, isolated perfused kidney (IPK) models have been invaluable preclinical tools that have led to numerous advancements over the decades, including understanding renal physiology, pharmacologic therapies, and improvements in renal transplantation. However, pre-existing IPK models are not without their own limitations, leaving areas for improvement. An isolated perfused kidney apparatus was designed to best recreate human use conditions as a preclinical tool. Porcine renal blocks were chosen over the more commonly used rodent models, due to their greater similarities to human anatomies. Sixteen porcine kidney pairs obtained en bloc were extracted and placed onto an apparatus where aortic flows, pressures, and overall systemic temperatures were controlled. Organ viability was assessed in 10 renal blocks (n = 8 fresh and n = 2 previously frozen specimens) via both urinary flows and compositions at timepoints up to 180 min. Multimodality imaging, which included fluoroscopy, ultrasound, optical coherence tomography (OCT), and video scopes, was also employed to capture internal and external images to determine renal artery orientations and dimensions. Anatomical measurements and viability assessments of porcine renal blocks were successfully achieved in our perfusion model. Renal main artery diameters averaged smaller in our sample size than in human anatomy while also having more superior takeoff angles. Yet, the average lengths of each main segment were comparable to human anatomy: 32.09 ± 7.97 mm and 42.23 ± 7.33 mm in the left and right renal main artery, respectively. Urine production and urine composition of the fresh renal blocks, when compared to the frozen blocks and baseline perfusate, showed kidney viabilities of up to 3 h via excretion and retention of various metabolites. In this paper, we described a protocol for an isolated perfused kidney apparatus using large mammalian renal blocks. We believe this protocol to be an improvement from similar pre-existing models in better representing human physiologic function while allowing for multimodal imaging. The resulting Visible Kidney™ preclinical model, which has shown viability after isolation and reperfusion, can be a fast and reliable tool for the development of medical devices while also reducing the unnecessary use of animals for research.


Assuntos
Líquidos Corporais , Transplante de Rim , Humanos , Suínos , Animais , Rim , Diurese , Aorta , Mamíferos
3.
Biomed Eng Online ; 22(1): 27, 2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36934270

RESUMO

BACKGROUND: Percutaneous coronary interventions (PCIs) within left main coronary arteries are high-risk procedures that require optimization of interactions between stent(s) and diseased vessels. Optical Coherence Tomography (OCT) is a widely accepted tool that enhances physicians' ability to assess proper stent appositions during clinical procedures. The primary aim of this study was to develop complementary post-procedure imaging methodologies to better assess and interpret outcomes of left main PCI procedures, utilizing both reanimated and perfusion-fixed human hearts. METHODS: PCIs were performed while obtaining OCT scans within the left main anatomies of six human hearts. Subsequently, each heart was scanned with a micro-CT scanner with optimized parameters to achieve resolutions up to 20 µm. Scans were reconstructed and imported into a DICOM segmentation software to generate computational models of implanted stents and associated coronary vessels. 2D images from OCT that were obtained during PCIs were compared to the 3D models generated from micro-CT reconstructions. In addition, the 3D models were utilized to create virtual reality scenes and enlarged 3D prints for development of "mixed reality" tools relative to bifurcation stenting within human left main coronary arteries. RESULTS: We developed reproducible methodologies for post-implant analyses of coronary artery stenting procedures. In addition, we generated high-resolution 3D computational models, with ~ 20-micron resolutions, of PCIs performed within reanimated and perfusion-fixed heart specimens. CONCLUSIONS: Generated computational models of left main PCIs performed in isolated human hearts can be used to obtain detailed measurements that provide further clinical insights on procedural outcomes. The 3D models from these procedures are useful for generating virtual reality scenes and 3D prints for physician training and education.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/métodos , Angiografia Coronária/métodos , Microtomografia por Raio-X , Resultado do Tratamento , Stents , Perfusão , Tomografia de Coerência Óptica/métodos
4.
J Cardiovasc Transl Res ; 16(4): 927-937, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36939960

RESUMO

Percutaneous coronary intervention can be a high-risk procedure that would benefit from optimizing device-tissue interactions between stents and coronary vessels. Using a perfusion-fixed human heart with coronary artery disease, we performed a percutaneous coronary intervention of the left main coronary artery bifurcation. This heart was perfused and multimodal imaging was utilized to view the procedure with direct visualization, fluoroscopy, and optical coherence tomography (OCT). We followed the European Bifurcation Club's guidelines to perform a single-stent bifurcation before transitioning to a two-stent Culotte technique. After each procedural step, the heart was removed from the perfusion apparatus and transferred to a micro-CT scanner to obtain unique scans. We conducted apposition analyses of the computational 3D models from micro-CT DICOM datasets, and compared them to the results from direct visualization and commercial OCT's Apposition Indicator software. Additional measurements of resulting coronary anatomic expansions were taken to determine the potential roles of each step in improving procedural outcomes. Micro-CT images show stent deformation during a percutaneous coronary intervention (provisional to Culotte bifurcation procedure) in an isolated diseased human heart.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Microtomografia por Raio-X , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Stents , Intervenção Coronária Percutânea/efeitos adversos , Perfusão , Imagem Multimodal , Angiografia Coronária/métodos
5.
Sci Rep ; 11(1): 12252, 2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112841

RESUMO

The structural morphology of coronary stents (e.g. stent expansion, lumen scaffolding, strut apposition, tissue protrusion, side branch jailing, strut fracture), and the local hemodynamic environment after stent deployment are key determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to enable the geometrically accurate three-dimensional (3D) reconstruction of coronary stents. The aim of this work was to present a novel algorithm for 3D stent reconstruction of coronary artery stents based on optical coherence tomography (OCT) and angiography, and test experimentally its accuracy, reproducibility, clinical feasibility, and ability to perform computational fluid dynamics (CFD) studies. Our method has the following steps: 3D lumen reconstruction based on OCT and angiography, stent strut segmentation in OCT images, packaging, rotation and straightening of the segmented struts, planar unrolling of the segmented struts, planar stent wireframe reconstruction, rolling back of the planar stent wireframe to the 3D reconstructed lumen, and final stent volume reconstruction. We tested the accuracy and reproducibility of our method in stented patient-specific silicone models using micro-computed tomography (µCT) and stereoscopy as references. The clinical feasibility and CFD studies were performed in clinically stented coronary bifurcations. The experimental and clinical studies showed that our algorithm (1) can reproduce the complex spatial stent configuration with high precision and reproducibility, (2) is feasible in 3D reconstructing stents deployed in bifurcations, and (3) enables CFD studies to assess the local hemodynamic environment within the stent. Notably, the high accuracy of our algorithm was consistent across different stent designs and diameters. Our method coupled with patient-specific CFD studies can lay the ground for optimization of stenting procedures, patient-specific computational stenting simulations, and research and development of new stent scaffolds and stenting techniques.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Imageamento Tridimensional , Stents , Cirurgia Assistida por Computador , Tomografia de Coerência Óptica , Algoritmos , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Humanos , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Microtomografia por Raio-X
7.
Int J Cardiovasc Imaging ; 37(9): 2591-2601, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33993420

RESUMO

Stent implantation in bifurcated coronary lesions is technically challenging so that procedural refinements are continuously investigated. Novel procedure modeling and intracoronary imaging techniques may offer critical insights on stent deformations and stent-wall interactions during bifurcation stenting procedures. Thus, we assessed coronary bifurcation stenting techniques using multimodal imaging and 3D modeling in reanimated swine hearts. Harvested swine hearts were reanimated using Visible Heart® methodologies and (under standard fluoroscopic guidance) used to test 1-stent (provisional and inverted provisional) and 2-stent (culotte, TAP and DK-crush) techniques on bifurcations within various coronary vessels using commercially available devices. Intracoronary angioscopy and frequency-domain optical-coherence-tomography (OCT) were obtained during the procedures. 3D OCT reconstruction and micro-computed tomography 3D modeling (post heart fixations) were used to assess stent deformations and stent-wall interactions. We conducted multiple stenting procedures and collected unique endoscopic and OCT images (and subsequent computational models from micro-CT) to assess stent deformations and device/wall interactions during different steps of bifurcation stenting procedures. Endoscopy, micro-CT and virtual reality processing documented that different 1- and 2-stent techniques, practiced according to experts' recommended steps, achieve optimal post-intervention stent conformation. As compared with intra-procedural endoscopy, software-generated 3D OCT images accurately depicted stent deformations during 1-stent techniques. On the opposite, during more complex 2-stent techniques, some defects were appreciated at 3D OCT reconstruction despite optimal 2D OCT images. This study provided unique insights regarding both stent deformations occurring in the course of bifurcation stenting and the efficacy of OCT to visualize them.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Animais , Angiografia Coronária , Imagem Multimodal , Valor Preditivo dos Testes , Stents , Suínos , Resultado do Tratamento , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA