Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Crit Rev Oncol Hematol ; 123: 52-56, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29482779

RESUMO

The incidence of squamous cell carcinoma of the anal canal (SCAC) is increasing in both sexes but the standard treatment remains that of 20 years ago. However, interesting data have recently emerged on the use of anti-epidermal growth factor receptor (EGFR) agents and immunotherapy in advanced disease. Thus, new avenues of research are opening up that will hopefully lead to more effective therapeutic strategies. We provide an overview of the latest studies published on this tumor and discuss the possible future therapeutic options for combination therapy, anti-EGFR treatment and radiotherapy.


Assuntos
Anticorpos Monoclonais/administração & dosagem , Antineoplásicos/administração & dosagem , Neoplasias do Ânus/terapia , Carcinoma de Células Escamosas/terapia , Receptores ErbB/antagonistas & inibidores , Imunoterapia/métodos , Neoplasias do Ânus/patologia , Carcinoma de Células Escamosas/patologia , Cetuximab/administração & dosagem , Terapia Combinada , Humanos , Terapias em Estudo/métodos
3.
J Prev Med Hyg ; 50(1): 33-6, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19771758

RESUMO

BACKGROUND: Nosocomial infections (NI) are above all due to health-care workers practices, but also the contamination of the environment could lead to their rise in health-care facilities. Introduction. In the last years, the incidence of NI has increased due to a substantial rise in the number of immuno-compromised patients. These patients are often gathered in hospital areas declared at "high risk" of infection such as Hematology and Bone Marrow Transplant ward. In this study, we evaluated microbial contamination of the air in two divisions with high risk patients, focusing on the validity of the air system with correlation to the presence or not of the HEPA absolute filters. METHODS: An environmental surveillance study has been carried out in two Divisions of Haematology, in two different Hospitals. Investigations have been performed by sampling air and by analyzing bacterial and fungal growth on microbiology plates after an incubation period. RESULTS: Unit A, without HEPA filters in the ventilation systems, showed a gradual increase in the bacterial load 20 and 60 days after cleaning of the ventilation system. Mycetes and Aspergilli were not present in basal conditions, at 20 or 60 days after decontamination. Unit B, equipped with HEPA filters placed at the inlet vents, showed extremely low values of the bacterial load either in basal conditions or upon inspection 60 days after cleaning. No mycetes were present. DISCUSSION: From the results obtained, it was evident that following the cleaning operation, the quality of the air is excellent in both types of equipment, since no mycetes were present and the bacterial load was < 20 CFU/mc in all the sites tested. However, although in subsequent controls mycetes were absent in both types of equipment, a great difference in the suspended bacterial load was found: Unit B was close to sterility whereas in Unit A a progressive increase was observed.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados/análise , Contaminação de Equipamentos , Filtração/instrumentação , Hematologia , Ventilação , Poluição do Ar em Ambientes Fechados/prevenção & controle , Contagem de Colônia Microbiana , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , Monitoramento Ambiental/métodos , Monitoramento Epidemiológico , Arquitetura Hospitalar , Unidades Hospitalares , Humanos , Hospedeiro Imunocomprometido , Incidência , Controle de Infecções/métodos , Itália/epidemiologia , Pneumopatias Fúngicas/epidemiologia , Pneumopatias Fúngicas/prevenção & controle , Ventilação/instrumentação , Ventilação/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA