RESUMO
Introduction: Decisions for plan-adaptations may be impacted by a transitioning from one dose-calculation algorithm to another. This study examines the impact on dosimetric-triggered offline adaptation in LA-NSCLC in the context of a transition from superposition/convolution dose calculation algorithm (Type-B) to linear Boltzmann equation solver dose calculation algorithms (Type-C). Materials & Methods: Two dosimetric-triggered offline adaptive treatment workflows are compared in a retrospective planning study on 30 LA-NSCLC patients. One workflow uses a Type-B dose calculation algorithm and the other uses Type-C. Treatment plans were re-calculated on the anatomy of a mid-treatment synthetic-CT utilizing the same algorithm utilized for pre-treatment planning. Assessment for plan-adaptation was evaluated through a decision model based on target coverage and OAR constraint violation. The impact of algorithm during treatment planning was controlled for by recalculating the Type-B plan with Type-C. Results: In the Type-B approach, 13 patients required adaptation due to OAR-constraint violations, while 15 patients required adaptation in the Type-C approach. For 8 out of 30 cases, the decision to adapt was opposite in both approaches. None of the patients in our dataset encountered CTV-target underdosage that necessitated plan-adaptation. Upon recalculating the Type-B approach with the Type-C algorithm, it was shown that 10 of the original Type-B plans revealed clinically relevant dose reductions (≥3%) on the CTV in their original plans. This re-calculation identified 21 plans in total that required ART. Discussion: In our study, nearly one-third of the cases would have a different decision for plan-adaption when utilizing Type-C instead of Type-B. There was no substantial increase in the total number of plan-adaptations for LA-NSCLC. However, Type-C is more sensitive to altered anatomy during treatment compared to Type-B. Recalculating Type-B plans with the Type-C algorithm revealed an increase from 13 to 21 cases triggering ART.
RESUMO
PURPOSE: Recently, it has been shown that automated treatment planning can be executed by direct fluence prediction from patient anatomy using convolutional neural networks. Proof of principle publications utilise a fixed dose prescription and fixed collimator (0°) and gantry angles. The goal of this work is to further develop these principles for the challenging lung cancer indication with variable dose prescriptions, collimator and gantry angles. First we investigate the impact of clinical applicable collimator angles and various input parameters. Then, the model is tested in a complete user independent planning workflow. METHODS: The dataset consists of 152 lung cancer patients, previously treated with IMRT. The patients are treated with either a left or a right beam setup and collimator angles and dose prescriptions adjusted to their tumour shape and stage. First we compare two CNNs with standard vs. personalised, clinical collimator angles. Next, four CNNs are trained with various combinations of CT and contour inputs. Finally, a complete user free treatment planning workflow is evaluated. RESULTS: The difference between the predicted and ground truth fluence maps for the fluence prediction CNN with all anatomical inputs in terms of the mean mean absolute error (MAE) is 4.17 × 10-4 for a fixed collimator angle and 5.46 × 10-4 for variable collimator angles. These differences vanish in terms of DVH metrics. Furthermore, the impact of anatomical inputs is small. The mean MAE is 5.88 × 10-4 if no anatomical information is given to the network. The DVH differences increase when a total user free planning workflow is examined. CONCLUSIONS: Fluence prediction with personalised collimator angles performs as good as fluence prediction with a standard collimator angle of zero degrees. The impact of anatomical inputs is small. The combination of a dose prediction and fluence prediction CNN deteriorates the fluence predictions. More investigation is required.
Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Radioterapia de Intensidade Modulada , Humanos , Pulmão , Neoplasias Pulmonares/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
The interest in machine learning (ML) has grown tremendously in recent years, partly due to the performance leap that occurred with new techniques of deep learning, convolutional neural networks for images, increased computational power, and wider availability of large datasets. Most fields of medicine follow that popular trend and, notably, radiation oncology is one of those that are at the forefront, with already a long tradition in using digital images and fully computerized workflows. ML models are driven by data, and in contrast with many statistical or physical models, they can be very large and complex, with countless generic parameters. This inevitably raises two questions, namely, the tight dependence between the models and the datasets that feed them, and the interpretability of the models, which scales with its complexity. Any problems in the data used to train the model will be later reflected in their performance. This, together with the low interpretability of ML models, makes their implementation into the clinical workflow particularly difficult. Building tools for risk assessment and quality assurance of ML models must involve then two main points: interpretability and data-model dependency. After a joint introduction of both radiation oncology and ML, this paper reviews the main risks and current solutions when applying the latter to workflows in the former. Risks associated with data and models, as well as their interaction, are detailed. Next, the core concepts of interpretability, explainability, and data-model dependency are formally defined and illustrated with examples. Afterwards, a broad discussion goes through key applications of ML in workflows of radiation oncology as well as vendors' perspectives for the clinical implementation of ML.
Assuntos
Radioterapia (Especialidade) , Aprendizado de Máquina , Redes Neurais de ComputaçãoRESUMO
Artificial intelligence (AI) has recently become a very popular buzzword, as a consequence of disruptive technical advances and impressive experimental results, notably in the field of image analysis and processing. In medicine, specialties where images are central, like radiology, pathology or oncology, have seized the opportunity and considerable efforts in research and development have been deployed to transfer the potential of AI to clinical applications. With AI becoming a more mainstream tool for typical medical imaging analysis tasks, such as diagnosis, segmentation, or classification, the key for a safe and efficient use of clinical AI applications relies, in part, on informed practitioners. The aim of this review is to present the basic technological pillars of AI, together with the state-of-the-art machine learning methods and their application to medical imaging. In addition, we discuss the new trends and future research directions. This will help the reader to understand how AI methods are now becoming an ubiquitous tool in any medical image analysis workflow and pave the way for the clinical implementation of AI-based solutions.
Assuntos
Inteligência Artificial , Radiologia , Algoritmos , Aprendizado de Máquina , TecnologiaRESUMO
Artificial Intelligence (AI) is currently being introduced into different domains, including medicine. Specifically in radiation oncology, machine learning models allow automation and optimization of the workflow. A lack of knowledge and interpretation of these AI models can hold back wide-spread and full deployment into clinical practice. To facilitate the integration of AI models in the radiotherapy workflow, generally applicable recommendations on implementation and quality assurance (QA) of AI models are presented. For commonly used applications in radiotherapy such as auto-segmentation, automated treatment planning and synthetic computed tomography (sCT) the basic concepts are discussed in depth. Emphasis is put on the commissioning, implementation and case-specific and routine QA of AI models needed for a methodical introduction in clinical practice.
Assuntos
Inteligência Artificial , Radioterapia (Especialidade) , Humanos , Aprendizado de Máquina , Planejamento da Radioterapia Assistida por Computador , Fluxo de TrabalhoRESUMO
BACKGROUND AND PURPOSE: The use of artificial intelligence (AI)/ machine learning (ML) applications in radiation oncology is emerging, however no clear guidelines on commissioning of ML-based applications exist. The purpose of this study was therefore to investigate the current use and needs to support implementation of ML-based applications in routine clinical practice. MATERIALS AND METHODS: A survey was conducted among medical physicists in radiation oncology, consisting of four parts: clinical applications (1), model training, acceptance and commissioning (2), quality assurance (QA) in clinical practice and General Data Protection Regulation (GDPR) (3), and need for education and guidelines (4). Survey answers of medical physicists of the same radiation oncology centre were treated as a separate unique responder in case reporting on different AI applications. RESULTS: In total, 213 medical physicists from 202 radiation oncology centres were included in the analysis. Sixty-nine percent (1 4 7) was using (37%) or preparing (32%) to use ML in clinic, mostly for contouring and treatment planning. In 86%, human observers were still involved in daily clinical use for quality check of the output of the ML algorithm. Knowledge on ethics, legislation and data sharing was limited and scattered among responders. Besides the need for (implementation) guidelines, training of medical physicists and larger databases containing multicentre data was found to be the top priority to accommodate the further introduction of ML in clinical practice. CONCLUSION: The results of this survey indicated the need for education and guidelines on the implementation and quality assurance of ML-based applications to benefit clinical introduction.