Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Orthod ; 46(4)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38895901

RESUMO

OBJECTIVES: This systematic review and meta-analysis aimed to investigate the accuracy and efficiency of artificial intelligence (AI)-driven automated landmark detection for cephalometric analysis on two-dimensional (2D) lateral cephalograms and three-dimensional (3D) cone-beam computed tomographic (CBCT) images. SEARCH METHODS: An electronic search was conducted in the following databases: PubMed, Web of Science, Embase, and grey literature with search timeline extending up to January 2024. SELECTION CRITERIA: Studies that employed AI for 2D or 3D cephalometric landmark detection were included. DATA COLLECTION AND ANALYSIS: The selection of studies, data extraction, and quality assessment of the included studies were performed independently by two reviewers. The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. A meta-analysis was conducted to evaluate the accuracy of the 2D landmarks identification based on both mean radial error and standard error. RESULTS: Following the removal of duplicates, title and abstract screening, and full-text reading, 34 publications were selected. Amongst these, 27 studies evaluated the accuracy of AI-driven automated landmarking on 2D lateral cephalograms, while 7 studies involved 3D-CBCT images. A meta-analysis, based on the success detection rate of landmark placement on 2D images, revealed that the error was below the clinically acceptable threshold of 2 mm (1.39 mm; 95% confidence interval: 0.85-1.92 mm). For 3D images, meta-analysis could not be conducted due to significant heterogeneity amongst the study designs. However, qualitative synthesis indicated that the mean error of landmark detection on 3D images ranged from 1.0 to 5.8 mm. Both automated 2D and 3D landmarking proved to be time-efficient, taking less than 1 min. Most studies exhibited a high risk of bias in data selection (n = 27) and reference standard (n = 29). CONCLUSION: The performance of AI-driven cephalometric landmark detection on both 2D cephalograms and 3D-CBCT images showed potential in terms of accuracy and time efficiency. However, the generalizability and robustness of these AI systems could benefit from further improvement. REGISTRATION: PROSPERO: CRD42022328800.


Assuntos
Pontos de Referência Anatômicos , Inteligência Artificial , Cefalometria , Imageamento Tridimensional , Cefalometria/métodos , Humanos , Pontos de Referência Anatômicos/diagnóstico por imagem , Imageamento Tridimensional/métodos , Tomografia Computadorizada de Feixe Cônico/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA