Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 13(5): 552-8, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9726321

RESUMO

A prospective study of 116 consecutive Kinemax cemented posterior cruciate ligament-retaining total knee arthroplasties was carried out. Similar surgical technique was used with a single variable: 61 were implanted using intramedullary guides on the tibia and 55 were implanted using extramedullary guides on the tibia. A radiographic study was performed after at least 1 year of follow-up to evaluate postoperative component position and compare the difference in the accuracy of positioning of the femoral and tibial components. Radiographic analysis showed that satisfactory position was achieved using both types of instrumentation. No statistically significant difference was observed in either the coronal or sagittal plane of the femoral component and the sagittal plane positioning of the tibial component. However, the coronal plane positioning of the tibial component revealed a statistically significant difference (P < .01), with intramedullary guides being superior to extramedullary guides. Also observed, was that using either technique, patients with less accurate postoperative positioning tended to be obese, with wide intramedullary canals. Patients with significant extraarticular deformities, marked bowing, and those with prior surgery or fractures may not be suitable for intramedullary guides, and they may require the use of extramedullary guides and intraoperative radiographic control. The ideal indication for the use of intramedullary instrumentation is in the patient who is not obese, with no extraarticular deformity, and with a well-defined, but not excessively wide, tibial medullary canal. Since tibial component malalignment in general, and coronal plane malalignment in particular, may adversely affect the long-term survival of total knee arthroplasties, the use of intramedullary alignment instrumentation is recommended when possible.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Idoso , Estudos de Casos e Controles , Cimentação , Feminino , Seguimentos , Humanos , Fixadores Internos , Articulação do Joelho/diagnóstico por imagem , Masculino , Desenho de Prótese , Radiografia , Tíbia/cirurgia , Fatores de Tempo
2.
Int Orthop ; 14(4): 367-9, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2076920

RESUMO

Extraskeletal osteosarcoma is very rare and is difficult to diagnose histologically. We report a case of a 63 year old women who had such a tumour in her thigh.


Assuntos
Osteossarcoma/diagnóstico por imagem , Neoplasias de Tecidos Moles/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Osteossarcoma/patologia , Osteossarcoma/cirurgia , Radiografia , Neoplasias de Tecidos Moles/patologia , Neoplasias de Tecidos Moles/cirurgia , Coxa da Perna
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA