Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 2(1): 29-34, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19808441

RESUMO

BACKGROUND: Although routinely administered, definitive evidence for the benefits of prophylactic antibiotics before the implantation of permanent pacemakers and implantable cardioverter-defibrillators from a large double-blinded placebo-controlled trial is lacking. The purpose of this study was to determine whether prophylactic antibiotic administration reduces the incidence of infection related to device implantation. METHODS AND RESULTS: This double blinded study included 1000 consecutive patients who presented for primary device (Pacemaker and implantable cardioverter-defibrillators) implantation or generator replacement randomized in a 1:1 fashion to prophylactic antibiotics or placebo. Intravenous administration of 1 g of cefazolin (group I) or placebo (group 2) was done immediately before the procedure. Follow-up was performed 10 days, 1, 3, and 6 months after discharge. The primary end point was any evidence of infection at the surgical incision (pulse generator pocket), or systemic infection related to be procedure. The safety committee interrupted the trial after 649 patients were enrolled due to a significant difference in favor of the antibiotic arm (group I: 2 of 314 infected patients-0.63%; group II: 11 of 335 to 3.28%; RR=0.19; P=0.016). The following risk factors were positively correlated with infection by univariate analysis: nonuse of preventive antibiotic (P=0.016); implant procedures (versus generator replacement: P=0.02); presence of postoperative hematoma (P=0.03) and procedure duration (P=0.009). Multivariable analysis identified nonuse of antibiotic (P=0.037) and postoperative hematoma (P=0.023) as independent predictors of infection. CONCLUSIONS: Antibiotic prophylaxis significantly reduces infectious complications in patients undergoing implantation of pacemakers or cardioverter-defibrillators.


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia , Cefazolina/administração & dosagem , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Infecção da Ferida Cirúrgica/prevenção & controle , Idoso , Método Duplo-Cego , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Fatores de Risco , Infecção da Ferida Cirúrgica/microbiologia , Infecção da Ferida Cirúrgica/mortalidade , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA