Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Acta Otolaryngol ; 130(11): 1242-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20632904

RESUMO

CONCLUSION: Sonotubometry with perfect sequences (PSEQ) was able to detect eustachian tube (ET) openings in both normal and pathological ears. Impaired ears showed ET openings in almost all cases; however, these proved to be not only less frequent, but also with lower amplitude and shorter duration. OBJECTIVES: To investigate the function of impaired ET under physiological conditions, using a novel kind of sound stimulus for sonotubometry ­ the PSEQ. METHODS: Twenty otologically healthy subjects (40 normal ears) and 32 patients with ear diseases (40 pathological ears) were examined sonotubometrically using noise signals with an ideally flat spectrum (PSEQ). Dry swallowing, water swallowing, and Toynbee maneuver were used to induce ET openings. Analysis was performed regarding the frequency of occurrence, duration, amplitude, and form of the ET openings. RESULTS: PSEQ allowed the detection of an ET opening in all 40 normal ears (91% of the performed maneuvers) and in 87.5% of the ears with impaired ET function (but only 47% of the maneuvers). The average amplitude of the openings in healthy ears was 16.86 dB, the average duration was 363 ms. In diseased ears these values were significantly lower: 9.73 dB, p < 0.001 and 280 ms, p < 0.05.


Assuntos
Técnicas de Diagnóstico Otológico , Otopatias/diagnóstico , Otopatias/patologia , Tuba Auditiva/patologia , Tuba Auditiva/fisiopatologia , Adolescente , Adulto , Criança , Deglutição , Técnicas de Diagnóstico Otológico/instrumentação , Otopatias/fisiopatologia , Estudos de Viabilidade , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
2.
Eur Arch Otorhinolaryngol ; 264(3): 231-6, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17028905

RESUMO

Sonotubometry allows an assessment of the Eustachian tube (ET) function under physiological conditions. The reliability of the application of an 8 kHz pure-tone signal was investigated. In 40 normal subjects (80 ears) sonotubometric studies were performed with a custom-made device. ET opening was provoked by swallowing, yawning and Valsalva manoeuvre. An opening was detected in all patients but not in all manoeuvres. Four characteristic sonotubogram types were found. Most common was the spike-type (60%). The double-peak and the plateau-shaped curves occurred in 17% each. The finding of an descendant curve was rare (5%). Of 623 measurements, only in 55% manouvres a positive sonotubometric result was found despite the fact that the patients reported an opening in all cases. The median opening time in dry swallowing, liquid swallowing, yawning and Valsalva was found to be 486, 355, 1,263 and 1,250 ms. A median sound increase of 16.0, 13.8, 15.0 and 15.0 dB was recorded for these manoeuvres. There was a statistic significant difference (P < 0.02) between the increase in sound intensity of liquid and dry swallowing. There was also a statistic significant difference found for the duration of the forced manoeuvres Valsalva and yawning as compared to dry and liquid swallowing (P < 0.0001). The use of an 8 kHz pure-tone signal showed a limited sensitivity for the detection of ET openings. This is mainly due to noise pollution, but also because of an altered positioning and/or dislocation of the probes and compression of the nostrils. The application of an 8 kHz signal is therefore not reliable enough for the use in practice. Further technical refinements and the use of alternative signals are necessary for a broader clinical application.


Assuntos
Audiometria de Tons Puros/instrumentação , Tuba Auditiva/fisiologia , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA