Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Small ; 18(37): e2201730, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35957542

RESUMO

Interface engineering is one of the promising strategies for the long-term stabilization of perovskite solar cells (PSCs), preventing chemical decomposition induced by external agents and promoting fast charge transfer. Recently, MXenes-2D structured transition metal carbides and nitrides with various functionalization (O, -F, -OH) have demonstrated high potential for mastering the work function in halide perovskite absorbers and have significantly improved the n-type charge collection in solar cells. This work demonstrates that MXenes allow for efficient stabilization of PSCs besides improving their performances. A mixed composite bathocuproine:MXene, that is, (BCP:MXene) interlayer, is introduced at the interface between an electron-transport layer (ETL) and a metal cathode in the p-i-n device structure. The investigation demonstrates that the use of BCP:MXene interlayer slightly increases the power conversation efficiency (PCE) for PSCs (from 16.5 for reference to 17.5%) but dramatically improves the out of Glove-Box stability. Under ISOS-L-2 light soaking stress at 63 ± 1.5 °C, the T80 (time needed to reduce efficiency down to 80% of the initial one) period increases from 460 to > 2300 hours (h).

3.
PLoS One ; 16(1): e0234284, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411740

RESUMO

OBJECTIVES: A multicenter study was organized to explore sources of variation (SVs) of reference values (RVs) for 22 major immunochemistry analytes and to determine reference intervals (RIs) for the Russian population. METHODS: According to IFCC Committee on Reference Intervals and Decision Limits (C-RIDL) protocol, 758 healthy volunteers were recruited in St. Petersburg, Moscow, and Yekaterinburg. Serum samples were tested for five tumor markers, 17 hormones and related tests by Beckman Coulter's UniCel DxI 800 immunochemistry analyzer. SVs were explored using multiple regression analysis and ANOVA. Standard deviation ratio (SDR) of 0.4 was used as primary guide for partitioning RIs by gender and age. RESULTS: SDR for between-city difference was <0.4 for all analytes. Secondary exclusion of individuals was done under the following conditions: for female sex-hormones, those with contraceptives (8%); for CA19-9, those supposed to have negative Lewis blood-group (10.5% males and 11.3% females); for insulin, those with BMI≥28 kg/m2 (31%); for the thyroid panel, those with anti-thyroid antibodies (10.3% males; 24.5% females), for CEA those with smoking habit (30% males and 16% females). Gender-specific RIs were required for all analytes except CA19-9, CA15-3, thyroid-related tests, parathyroid hormone, and insulin. Age-specific RIs were required for alpha-fetoprotein, CEA, all sex-hormones for females, FSH and progesterone for both sexes. RIs were generally derived by parametric method after Gaussian transformation using modified Box-Cox formula. Exceptions were growth hormone, estradiol for females in postmenopause, and progesterone for females in premenopause, for which nonparametric method was required due to bimodal distribution and/or insufficient detection limit. CONCLUSION: RIs for major hormones and tumor markers specific for the Russian population were derived based on the up-to-date internationally harmonized protocol by careful consideration of analyte-specific SVs.


Assuntos
Biomarcadores Tumorais/metabolismo , Hormônios/metabolismo , Adolescente , Adulto , Idoso , Antígeno CA-19-9/metabolismo , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Mucina-1/metabolismo , Análise Multivariada , Valores de Referência , Análise de Regressão , Federação Russa , Adulto Jovem , alfa-Fetoproteínas/metabolismo
4.
Clin Biochem ; 81: 47-58, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32278594

RESUMO

OBJECTIVES: Because reference intervals (RIs) for biochemistry analytes matched to the Russian population are not well defined, we joined the global study on reference values (RVs) coordinated by the IFCC Committee on Reference Intervals and Decision Limits (C-RIDL). METHODS: According to the C-RIDL harmonized protocol, 793 healthy volunteers were recruited in Saint-Petersburg, Moscow, and Yekaterinburg. Serum samples were tested for 34 biochemistry analytes. Sources of variation of RVs were explored using multiple regression analysis. The need for partitioning RVs by sex and age were judged using standard deviation ratio based on ANOVA. Latent abnormal values exclusion (LAVE) method was applied to reduce the influence of individuals with metabolic syndrome and/or inappropriate sampling conditions. RIs were computed by the parametric method. RESULTS: No appreciable between-city differences were observed. Partition of RVs by sex was required for 17 analytes. Age-related changes in RVs were observed in many analytes, especially in females. The trend was exaggerated in nutritional and inflammatory markers that were closely associated with body mass index (BMI), because BMI increases prominently with age. Therefore, for those analytes, volunteers with BMI > 28 kg/m2 were excluded in determining RIs for age-specific RIs. The LAVE method was effective in lowering the upper limits of the RIs for nutritional and inflammatory markers. CONCLUSION: RIs matched to the Russian population were established for 34 biochemical analytes using up-to-date methods in detailed consideration of sources of variation of RVs. The majority of Russian RIs are similar to those of Caucasian populations among the participating countries.


Assuntos
Biomarcadores/sangue , Índice de Massa Corporal , Testes de Química Clínica/normas , Saúde Global/normas , Síndrome Metabólica/diagnóstico , Adolescente , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Síndrome Metabólica/sangue , Pessoa de Meia-Idade , Valores de Referência , Federação Russa , Adulto Jovem
5.
Sensors (Basel) ; 17(8)2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28777291

RESUMO

The availability of silicon photonic integrated circuits (ICs) in the 2-4 µm wavelength range enables miniature optical sensors for trace gas and bio-molecule detection. In this paper, we review our recent work on III-V-on-silicon waveguide circuits for spectroscopic sensing in this wavelength range. We first present results on the heterogeneous integration of 2.3 µm wavelength III-V laser sources and photodetectors on silicon photonic ICs for fully integrated optical sensors. Then a compact 2 µm wavelength widely tunable external cavity laser using a silicon photonic IC for the wavelength selective feedback is shown. High-performance silicon arrayed waveguide grating spectrometers are also presented. Further we show an on-chip photothermal transducer using a suspended silicon-on-insulator microring resonator used for mid-infrared photothermal spectroscopy.

6.
Beilstein J Nanotechnol ; 4: 446-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23946913

RESUMO

The Re3As7- x In x solid solution was prepared for x ≤ 0.5 by heating the elements in stoichiometric ratios in evacuated silica tubes at 1073 K. It crystallizes with the Ir3Ge7 crystal structure, space group Im-3m, with a unit-cell parameter a ranging from 8.716 to 8.747 Å. The crystal structure and properties were investigated for a composition with x = 0.4. It is shown that indium substitutes arsenic exclusively at one crystallographic site, such that the As-As dumbbells with d As-As = 2.54 Å remain intact. Re3As6.6In0.4 behaves as a bad metal or heavily doped semiconductor, with electrons being the dominant charge carriers. It possesses high values of Seebeck coefficient and low thermal conductivity, but relatively low electrical conductivity, which leads to rather low values of the thermoelectric figure of merit.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA